Recommended Runs for immediate Data Analysis
Go get the from the runs database
...
Synchronized runs (check tags in rcReport and txt files in run directory) :
+ 700000475 : 10k events, external trigger on scintillators.
+ 700000502 : external trigger on scintillators, new ancillary DAQ
Important Detector Register Settings for CAL CPTs
Values are coming mostly from LAT70X used for LAT Integration
Expected value for most important registers in DAC Counts or system clock ticks
CAL
- CAL Range Decision Time (GTEM/GCCC/GCRC/delay_1) : 31
- CAL Time After Range Decision Until ADC Readout Time (GTEM/GCCC/GCRC/delay_2) : 53
- CAL ADC Readout Time (GTEM/GCCC/GCRC/delay_3) : 133
- CAL Log Accept Discriminator (zero suppression) (GTEM/GCCC/GCRC/GCFE/log_acpt) : 20 to 50 for ~ 2 MeV settings at LE gain = 5
- CAL High Energy Trigger Discriminator (GTEM/GCCC/GCRC/GCFE/fhe_dac) xxxxxx settings at LE gain = 5
- CAL Low Energy Trigger Discriminator (GTEM/GCCC/GCRC/GCFE/fle_dac) xxxx 1000 MeV settings at HE gain = 15
- CAL Readout Range Select Discriminator (GTEM/GCCC/GCRC/GCFE/rng_uld_dac) : 120 = default; 105 to 120 for optimal settings
- CAL DAC for DC Reference (GTEM/GCCC/GCRC/GCFE/ref_dac) : 0
Important Detector Register Settings for end-to-end runs (baseline data taking)
...