Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

System Tests for this version

System Tests results:

http://glast-ground.slac.stanford.edu/SystemTests/summary.jsp?model=EngModelNo differences wrt previous pipeline version. 

...

eLog: v2r3p1
ConfigTables: v3r2p1

TestReport: v3r6p4 v3r6p11 (digi & recon reports): EAC and awb
- Added ACD electronics space and ACD trigger quantities.  Also improved descriptions.
- Protect code against time hacks being the same in two events.
- Get GEM discarded counter from context information instead of directly from the GEM.
- Added number of prescaled and dead zone events. Added histogram with delta deadzone events.
- Added check on the consistency between the GEM sequence counter and the number of events in the digi file.
- Added trigger/deadzone/discarded rates for 30 time intervals. In case of problems it may tell us where in a run it happened and speed up troubleshooting.
- Added consistency check on all extended counters so we'll know when the go backwards.
- Added much better error decoding. Will now know what the TEM errors are (TKR FIFO full or not).
- Added trigger arrival time histograms.
- Added ACD MIP peak histograms.

EngineeringModelRoot: v2r2 (SVAC tuple)
- Added a few useful AcdMips variables (sum and max and error flag).
- Added more error flags.
- Updated documention.

Approved: unanimous (Bill not available) - 5/19/06

 

Added 06.01.2006 for book keeping purposes (for the moment): Bryson's CHS task
- Bryson IExternal/fsw v0r069  -- incorporates DFI, etc. from FSW B0-6-9 with the 24/25-bit fix for the livetime counter.
- Bryson CHS/eventFile v1r0p9 -- bunch of tweaks mostly to rqts file for building on Windows.
- Bryson CHS v2r2                  -- updated checkout package to pull in these two new tags.

Verify that number of events in input files are the same.
- Added Ground ID to the top of the report.
- Look for missing datagrams. Consistency checks on opening/closing of datagrams.
-  Fix one of the ACD veto fraction plot to show fraction of digi above threshold, rather than below.  
   Also, make single veto fraction relative to total number of vetos, not total number of digis.

EngineeringModelRoot: v3r0 (SVAC tuple)
- Mutsumi's TKR stuff now depends on calibTkrUtil so EngineeringModelRoot and BeamTest can use the same code.
- No changes to SVAC code.