Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Code Versions

Engineering Model (sim/recon):

...

v6r070329p11https://www.slac.stanford.edu/www-glast-dev/cgi/detailedSummary?sessionId=36f0e3023cb3adf81d530377ea8a0ab1&cpId=6244

 

 

 

System Tests for this version

System Tests results:

Verified by Anders et al. Two differences in Acd histograms for VerticalGamma100MeV: One due to code changes (system test code needs to be updated wrt fetching Acd Poca information),  and a tiny difference in the number of ACD-TKR intersections (understood by Eric Charles: due to improvement in the code)Differences in vdg_oneTower test due to changes in source location. Changes in VerticalGamma100MeV due to ACD veto change from 0.1 MIP to 0.3 MIP.

Fred version:

v0r99

Pipeline version:

...

eLog: v2r3p1
ConfigTables: v3r2p1

TestReport: v3r4p15 v3r5p6 (digi & recon reports):
- Put in a 'isLATTE' flag. Only show SBC histograms for LATTE runs.
- Add in a zoom of the GEM delta event time (1 ms).
- Added (datagram) time stamps for LICOS runs
- Added ACD electronics space and ACD trigger quantities.  Also improved descriptions.
- Protect against time hacks being the same in two events.
- Get GEM discarded counter from context information. Drop rollover protection.
- Added number of prescaled and dead zone events.
- Added check on the consistency between the GEM sequence counter and the number of events in the digi file.
- Added more context/time tone information.
- Added trigger/deadzone/discarded rates for 30 time intervals. In case of problems it may tell us where in a run it happened and speed up troubleshooting.
- Added consistency check on extended counters. 

EngineeringModelRoot: v1r18 EngineeringModelRoot: v1r15 (SVAC tuple)
- Added Context variables.
- Added Acd TkrPoint and Acd Gap variablesa few useful AcdMips variables (sum and max and error flag).
- Updated Acd Poca code to work with new AcdRecon. documention.

Approved: