- 3/2/2012 - Define block 1 as the 776 runs in P202-ROOT block 1. Configure trickleStream and begin (14:08)
- 3/31/2012 - Define block 2 as 5600 runs. Reconfig trickleStream and begin (18:05)
- 4/01/2012 - Block 2 complete (most of the 4824 jobs completed in about six hours w/1000 job limit).
- 5/31/2012
- Discover stream 5599 (run 271999199) requires rollback - new MERIT file version (v203->v205).
- Regenerate runlist with 20,229 input MERIT files.
- Minor config change: twoClumpMin=False (formerly True, but caused unnecessary extra processClump dummy jobs)
- 6/5/2012 - Final cleanup
- Five runs are responsible for discrepant event tallies:
Run
Stream
Reason
Action
239557414
0
bad TCut
rollback ROOT + FITS
241599746
352
bad processing order
rollback FITS
245403855
1019
bad start time
change start time in runList and rollback
332661583
16244
silent root errors
rollback ROOT
339081502
17416
silent root errors
rollback ROOT
- Code changes:
directory
script
modification
commonTools/00-01-00
repTools.py
added new getKey() function to extract #events from FITS event files
<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="1b312a9483077ec7-20079120-47da4407-b783b936-4b8dc4c74e4557c0447d4306"><ac:plain-text-body><![CDATA[
P202-FITS/config
config.py
added os.environ['HEADASNOQUERY']='true' to enable 'ftlist' to run in batch
]]></ac:plain-text-body></ac:structured-macro>
P202-FITS/config
makeFITS.py
add diagnostic print of #evts in FITS files for each processing sub-step
- After these actions, the dataCatalog tallies are now consistent: Note that the number of events in ELECTRONFT1 files are not currently tallied by the dataCatalog.
Name
Type
Files
Events
Size
Created (UTC)
Links
Group
20229
0
8.5 GB
02-Mar-2012 00:06:07
Group
20229
90,904,582
205.7 GB
25-Jan-2012 00:53:32
Group
20229
189,323,074
17.8 GB
02-Mar-2012 00:06:06
Group
20229
1,325,204,821
215.3 GB
02-Mar-2012 00:06:08
Group
20229
6,291,424,926
574.7 GB
02-Mar-2012 00:06:09
Group
20229
6,291,424,926
1,020.1 GB
02-Mar-2012 00:06:09
Group
20229
6,291,424,926
5.3 TB
25-Jan-2012 00:53:29
Group
20229
44,125,679,961
35.4 TB
25-Jan-2012 00:53:30
Group
20229
44,125,679,961
590.0 TB
25-Jan-2012 00:53:33
Group
20229
44,125,679,961
942.7 GB
25-Jan-2012 00:53:31
Group
20229
44,125,679,961
128.7 TB
25-Jan-2012 00:53:31
- Five runs are responsible for discrepant event tallies:
- 8/24/2012 - Configure and run backfill through 31 July 2012
...
<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="5107822de98d66fd-b863954f-45644551-8cf5933f-df7c65344797d75d5d5a618c"><ac:plain-text-body><![CDATA[ | Data Product | destination | data content [1] | event selection [1] | makeFT1 | gtselect | gtdiffrsp | gtmktime | ]]></ac:plain-text-body></ac:structured-macro> |
---|---|---|---|---|---|---|---|---|---|
EXTENDEDFT1 | SLAC | FT1variables | ((FT1EventClass & 0x00003EFF)!=0) | | | | | ||
FT1 | FSSC+SLAC | FT1variables | 'source' and above | | | (inherited) | | ||
EXTENDEDLS1 | SLAC | LS1variables | ((FT1EventClass & 0x00003EFF)!=0) | | | | | ||
LS1 | FSSC+SLAC | LS1variables | 'transient' and above | | | (inherited) | | ||
ELECTRONFT1 | SLAC | FT1variables | CTBParticleType==1 | | | | |
...
Identical with P202-ROOT except for the list of runs to be processed...with one exception: to reprocess the four extra (out-of-order) L&EO runs, disable the event list sort.