Currently in the simulation we model the blanket as simple boxes on the top and four sides without the crown. It may be time to modify that. But for the time being we will provide number both for this simplified blanket model and something closer to reality that includes the crown. Using a conversion factor of 2.54 to get cm from inches.
Simplified version (without crown):
Distance from bottom of MMS and top of top ACD tiles: 32.3 .23 cmmm
Distance from bottom of MMS and top of side ACD tiles: 02.23 cm3 mm
Distance between MMS and start of side ACD tiles: 118.80 cm0 mm
With Crown:
Distance from bottom of MMS and top of top ACD tiles: 06.69 cm9 mm
Distance from bottom of MMS and top of side ACD tiles: 02.23 cm3 mm
Distance between MMS and start of side ACD tiles: 118.80 cm0 mm
Note that the big difference is the distance between the top of the ACD tiles and the bottom of blanket, due to the need in the simplified model to have one box represent the blanket along the top, which must also clear the crown of the tiles themselves.
...