Page History
Optical measurement
Run 5 CSPad2-DSD metrology files from Chris Kenney:
2012-01-10-CSPAD2-Configuration.pptx
2012-01-10-Run5-DSD-Metrology.xlsx
2012-01-10-Run5-DSD-Metrology.txt
2012-01-12-Run5-DSD-Metrology-corrected.xlsx
2012-01-12-Run5-DSD-Metrology-corrected.txt
Procedure and table of results
We calculate
S1 - 1st short side of 2x1
S2 - 2nd short side of 2x1
L1 - 1st long side of 2x1
L2 - 2nd long side of 2x1
...
- All ds1, dl1 are well consistent (within +/-10um) with ds1, dl1, respectively
- Angles of 2x1 are in the range from -0.39 to +0.33 degree.
Configuration parameters
Configuration parameters are shown in number of pixels.
For 2x1 pairs in each quad
Coordinates of the 2x1 centers
- Use the same orientation as in optical measurement, center is calculated as an average of 4 corner coordinates
- All coordinates in pixels
...
center_corr/0-end.data
are all zeros
2x1-pair orientation angle (degree) in quads
rotation/0-end.data
Code Block |
---|
0 0 270 270 180 180 270 270 0 0 270 270 180 180 270 270 0 0 270 270 180 180 270 270 0 0 270 270 180 180 270 270 |
Sensor tilt angle (dergee) from optical measurement
tilt/0-end.data
for dPhi:
Code Block |
---|
-0.02500 0.00329 -0.16977 -0.13423 -0.32451 -0.25566 0.02698 0.31916 -0.02369 0.00461 0.24123 0.06686 -0.22574 -0.26358 -0.16712 0.16513 -0.03159 0.01447 0.00526 0.33226 -0.17809 0.10962 -0.26712 -0.19214 -0.12963 0.00526 -0.23951 -0.22634 0.23030 0.08285 0.05132 0.06119 |
Quads' alignment
Relative quads' alignment is preliminary done based on cxi80410-r1150, based on DSD image averaged over 1000 events,
where the shadow of mechanical parts can be destinguished. In order to lign-up the boarders of this shadow we apply constants:
marg_gap_shift/0-end.data
...