ppic -d -v
need to have ipmi daemon running to talk to "carbondale" chip
(if not, ppic will try to start ipmi itself, but doesn't do it right)
Checking RAID Controller
install rpm for hpacucli
/nfs/slac/g/suncatfs/sw/package/smartshow
options
Usage: ./smartshow with flags one of -c -d -e -1 -a -l -D
-c shows controller status
-d show disk
-1 show disk compact (1 line per)
-e show enclosure
-l logical drives
location, status, size, model number, firmware rev
1I:1:1: OK: 500 GB: HP MM0500FAMYT : HPD3
1I:1:2: OK: 500 GB: HP MM0500FAMYT : HPD3
2E:1:1: OK: 600 GB: HP EF0600FARNA : HPD2
2E:1:2: OK: 600 GB: HP EF0600FARNA : HPD2
2E:1:3: OK: 600 GB: HP EF0600FARNA : HPD2
2E:1:4: OK: 600 GB: HP EF0600FARNA : HPD2
2E:1:5: OK: 600 GB: HP EF0600FARNA : HPD2
2E:1:6: OK: 600 GB: HP EF0600FARNA : HPD2
2E:1:7: OK: 600 GB: HP EF0600FARNA : HPD2
2E:1:8: OK: 600 GB: HP EF0600FARNA : HPD2
2E:1:9: OK: 600 GB: HP EF0600FARNA : HPD2
2E:1:10: OK: 600 GB: HP EF0600FARNA : HPD2
2E:1:11: OK: 600 GB: HP EF0600FARNA : HPD2
2E:1:12: OK: 600 GB: HP EF0600FARNA : HPD2