This is a short example on how to run the MCFast tool, generate a list of reconstructed particles and run a Jet Cluster
Requirements
- JAS3 must be installed
- Get a stdhep file, Z Pole stdhep from the SLAC HEP repository
- Select sid01 as detector version when JAS3 prompts you
The Code
import java.io.File; import java.util.List; import java.util.ArrayList; import org.lcsim.mc.fast.MCFast; import org.lcsim.util.Driver; import org.lcsim.util.loop.LCIODriver; import org.lcsim.event.EventHeader; import org.lcsim.event.ReconstructedParticle; import org.lcsim.event.util.JetDriver; import hep.physics.jet.*; public class SimpleEventSim extends Driver { int ievt=0; String LCIOoutputfilename="fastmcZuds.slcio"; String jetlistname = "Jets"; public SimpleEventSim() { // Create MCFast with standard options Driver fast = new MCFast(); // Turn on diagnostic histograms fast.setHistogramLevel(HLEVEL_NORMAL); // Add as sub-driver add(fast); // set up Jet Finder JetDriver j = new JetDriver(); j.setInputCollectionName("MCFastReconstructedParticles"); j.setOutputCollectionName(jetlistname); JetFinder twojet = new FixNumberOfJetsFinder(2); j.setFinder(twojet); add(j); // write lcio files File output = new File(System.getProperty("user.home"),LCIOoutputfilename); add(new LCIODriver(output)); } protected void process(EventHeader event) { // call other driver process methods super.process(event); // give some status on events if (ievt%50==0) { System.out.println("Processed Events " + ievt); } ievt++; } }
Loading this code into JAS will run over the stdhep file and generate and output LCIO file for analysis later
MCFAST
// Create MCFast with standard options Driver fast = new MCFast(); // Turn on diagnostic histograms fast.setHistogramLevel(HLEVEL_NORMAL); // Add as sub-driver add(fast);
This initializes the fast Monte-Carlo Generator and adds it to the event loop
JET Clustering
// set up Jet Finder JetDriver j = new JetDriver(); j.setInputCollectionName("MCFastReconstructedParticles"); j.setOutputCollectionName(jetlistname); JetFinder twojet = new FixNumberOfJetsFinder(2); j.setFinder(twojet); add(j);
The JetDriver needs an input and output collection and a separate JetFinder, which in this example is a FixNumberOfJetsFinder finder. The JetFinder Object is then added to the JetDriver. For details see the FreeHep JetFinder documentation.
LCIO output
// write lcio files File output = new File(System.getProperty("user.home"),LCIOoutputfilename); add(new LCIODriver(output));
This opens a new file and writes all LCIO Collections into the file.