- Created by Kelly (Arrighi), Heather, last modified on Nov 03, 2021
setup_sn_all.sh Expand source
# Feb 2020: install SNANA on Cori # Apr 25 2020: load root # Aug 14 2020: load cfitsio & gsl # Feb 22 2021: R.Kessler - update & add ENVs for SNANA # Mar 05 2021: define few things for CosmoMC (installed by Vivian) # module unload python module unload PrgEnv-intel/6.0.5 module load PrgEnv-gnu/6.0.5 module swap gcc gcc/9.3.0 module rm craype-network-aries module rm cray-libsci module unload craype module load cfitsio/3.47 module add gsl module load root/6.18.00-py3 module load intel/19.1.3.304 # for CosmoMC (Mar 5 2021) export CC=gcc # add SNANA to path export SN_GROUP='/global/cfs/cdirs/lsst/groups/SN' export SNANA_DIR="$SN_GROUP/snana/SNANA" export SNDATA_ROOT="$SN_GROUP/snana/SNDATA_ROOT" export SNANA_TESTS="$SN_GROUP/snana/SNANA_TESTS" export SNANA_SURVEYS="$SN_GROUP/snana/SURVEYS" export SNANA_LSST_ROOT="$SNANA_SURVEYS/LSST/ROOT" export SNANA_LSST_USERS="$SNANA_SURVEYS/LSST/USERS" export SNANA_LSST_SIM="/global/cscratch1/sd/kessler/SNANA_LSST_SIM" export SNANA_ZTF_SIM="/global/cscratch1/sd/kessler/SNANA_ZTF_SIM" export DES_ROOT="$SNANA_SURVEYS/DES/ROOT" export PLASTICC_ROOT="$SNANA_SURVEYS/LSST/ROOT/PLASTICC" export PLASTICC_MODELS="$PLASTICC_ROOT/model_libs" export PIPPIN_OUTPUT="/global/cscratch1/sd/kessler/PIPPIN_OUTPUT" export PIPPIN_DIR="$SN_GROUP/Pippin" export SBATCH_TEMPLATES="$SNANA_LSST_ROOT/SBATCH_TEMPLATES" export COSMOMC_DIR="$SN_GROUP/CosmoMCBBC" export PATH=$PATH:${COSMOMC_DIR} export PATH=$PATH:${SNANA_DIR}/bin:${SNANA_DIR}/util:${PIPPIN_DIR} # Aug 24 2020 RK - silly hack for CFITSIO export LD_LIBRARY_PATH=$LD_LIBRARY_PATH:$CFITSIO_DIR/lib # Set up SN python export LSST_INST_DIR=/global/common/software/lsst/common/miniconda export SN_PYTHON_VER=sn-py module unload python unset PYTHONHOME unset PYTHONPATH export PYTHONNOUSERSITE=' ' # Just in case GCRCatalogs is installed export DESC_GCR_SITE='nersc' source $LSST_INST_DIR/$SN_PYTHON_VER/etc/profile.d/conda.sh conda activate root OUTPUTPY="$(which python)" echo Now using "${OUTPUTPY}" export HDF5_USE_FILE_LOCKING=FALSE
setup_sn_some.sh Expand source
# Feb 2020: install SNANA on Cori # Apr 25 2020: load root # Aug 14 2020: load cfitsio & gsl # Feb 22 2021: R.Kessler - update & add ENVs for SNANA # Mar 05 2021: define few things for CosmoMC (installed by Vivian) # module load cfitsio/3.47 module load root/6.18.00-py3 source /global/common/software/lsst/cori-haswell-gcc/stack/setup_any_stack.sh w_2021_40 # add SNANA to path export SN_GROUP='/global/cfs/cdirs/lsst/groups/SN' export SNANA_DIR="$SN_GROUP/snana/SNANA" export SNDATA_ROOT="$SN_GROUP/snana/SNDATA_ROOT" export SNANA_TESTS="$SN_GROUP/snana/SNANA_TESTS" export SNANA_SURVEYS="$SN_GROUP/snana/SURVEYS" export SNANA_LSST_ROOT="$SNANA_SURVEYS/LSST/ROOT" export SNANA_LSST_USERS="$SNANA_SURVEYS/LSST/USERS" export SNANA_LSST_SIM="/global/cscratch1/sd/kessler/SNANA_LSST_SIM" export SNANA_ZTF_SIM="/global/cscratch1/sd/kessler/SNANA_ZTF_SIM" export DES_ROOT="$SNANA_SURVEYS/DES/ROOT" export PLASTICC_ROOT="$SNANA_SURVEYS/LSST/ROOT/PLASTICC" export PLASTICC_MODELS="$PLASTICC_ROOT/model_libs" export PIPPIN_OUTPUT="/global/cscratch1/sd/kessler/PIPPIN_OUTPUT" export PIPPIN_DIR="$SN_GROUP/Pippin" export SBATCH_TEMPLATES="$SNANA_LSST_ROOT/SBATCH_TEMPLATES" export PATH=$PATH:${SNANA_DIR}/bin:${SNANA_DIR}/util:${PIPPIN_DIR} # Aug 24 2020 RK - silly hack for CFITSIO export LD_LIBRARY_PATH=$LD_LIBRARY_PATH:$CFITSIO_DIR/lib #export LD_LIBRARY_PATH=$LD_LIBRARY_PATH:/cvmfs/sw.lsst.eu/linux-x86_64/lsst_dis trib/w_2021_40/conda/miniconda3-py38_4.9.2/envs/lsst-scipipe-0.7.0/lib export PYTHONPATH=$PYTHONPATH:/global/common/software/lsst/common/miniconda/sn-s print-oct21/cvmfs/sw.lsst.eu/linux-x86_64/lsst_distrib/w_2021_40/conda/miniconda3-py38_4.9.2/envs/lsst-scipipe-0.7.0-ext/lib/python3.8/site-packages
- No labels