Name | Description | Notes | |
---|---|---|---|
1 | Cost | ~$2k/unit | |
2 | PCIe Slot Width | single slot width | |
3 | PCIe Lanes | 16 lanes | |
4 | PCIe Speed | GEN3 (or better) | |
5 | Cooling | Active Cooling | |
6 | Max. Power | 75W | |
7 | On Board Memory | 4 separate DDR4 interface | |
8 | Optical Links | 8 (or more) | |
9 | Optical Link speed | 10Gb/s (or better) |
Manufacture | Part# | Cost
| PCIe Slot Width | PCIe Lanes | PCIe Speed | Cooling | Max. Power | On-Board Memory | Optical Links | Optical Link Speed | slaclab/axi-pcie-core Supported | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | SLAC | XCKU040-2FFVA1156E Design | ~$2k/unit (includes step pricing) | Single | 8 | GEN3 | Active Only | 75W | None | 2 QSFP + 2 SFP+ | 16Gb/s | No because doesn't exist yet |
2 | SLAC | XCKU060-2FFVA1156E Design | ~$3k/unit (includes step pricing) | Single | 16 | GEN3 | Active Only | 75W | None | 2 QSFP + 2 SFP+ | 16Gb/s | No because doesn't exist yet |
3 | SLAC | XCKU15P-2FFVA1156E Design | ~$4k/unit (includes step pricing) | Single | 16 | GEN3 | Active Only | 75W | None | 2 QSFP + 2 SFP+ | 16Gb/s | No because doesn't exist yet |
4 | Xilinx | Alveo U50 | $3k/unit | Single | 16 | GEN4 | Passive Only | 75W | 8 GB HBM2 | 4 | 28Gb/s | Supported |
5 | Xilinx | Alveo U200 | $4.8k/unit | Double | 16 | GEN3 | Active or Passive | 225W | 64 GB DDR4 | 8 | 28Gb/s | Supported |
6 | Xilinx | Alveo U250 | $7.5k/unit | Double | 16 | GEN3 | Active or Passive | 225W | 64 GB DDR4 | 8 | 28Gb/s | Supported |
7 | Xilinx | Alveo U280 | $7.6k/unit | Double | 16 | GEN4 | Active or Passive | 225W | 32 GB DDR4 + 8 GB HBM2 | 8 | 28Gb/s | Supported |
8 | Alpha-Data | ADM-PCIE-KU3 | $2.8k/unit | Single | 16 | GEN3 | Active or Passive | 75W | 16 GB DDR4 | 8 | 16Gb/s | Supported |
9 | Alpha-Data | ADM-PCIE-8K5 | $4.8k/unit | Single | 8 | GEN3 | Active or Passive | 75W | 16 GB DDR4 | 2 SFP+ & 8 Firefly | 16Gb/s | Not Yet |
10 | Alpha-Data | ADM-PCIE-9V3 | $5.0k/unit | Single | 16 | GEN4 | Active or Passive | 75W | 16 GB DDR4 | 8 | 28Gb/s | Not Yet |
11 | Alpha-Data | ADM-PCIE-9V5 | $6.9k/unit | Single | 8 | GEN4 | Active or Passive | 141W | None | 16 | 28Gb/s | Not Yet |
12 | BittWare | XUPP3R | $8.4k/unit | Double | 16 | GEN3 | Active or Passive | 225W | Up to 128 GB DDR4 | 16 | 28Gb/s | Not Yet |
13 | BittWare | XUPPL4 | $4.9k/unit | Single | 16 | GEN3 | Active Only | 75W | Up to 32 GB DDR4 | 8 | 28Gb/s | Not Yet |
14 | Hitech Global | HTG-K805 | $5.5k/unit | Single | 16 | GEN3 | Active Only | 75W | Up to 4 GB DDR4 | 16 | 16Gb/s | Not Yet |
15 | Hitech Global | HTG-910 | $10k/unit | Single | 8 | GEN4 | Active Only | 225W?? | 34 GB DDR4 | 8 SFP+ & 8 Firefly | 28Gb/s | Not Yet |