Confluence will be down for maintenance June 14 2024 at 6AM PT.
This page is intended to summarize different power supply modules and regulators that have been, or might be used, in the cameras developed within the TID-ID-ECS department.
If a regulator seems interesting and you want to try it, scroll to the column on the far right and check if an evaluation board has already been purchased for the TID-ID-ECS department.
Type | Manufacturer | Part number (Manufacturer link) | PMBUS | Current monitor | Vin min | Vin max | Vout min | Vout max | Output current | Noise figure | Dimensions [mm] | Area [mm2] | Package | Price (2024) | Note | Used in project | Evaluation board (green means TID-ID-ECS has it) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Buck | Texas Instruments | TPSM5D1806 | No | No | 4.5V | 15V | 0.5V | 5.5V | 6A x2 | ±1% voltage reference accuracy | 8x5.5x1.9 | 44 | 51-BQFN | $24 | GT Readout Platform | TPSM5D1806EVM | |
Buck | Murata | MYMGM1R824ELA5RA | Yes | Yes | 7.5V | 15V | 0.7V | 1.8V | 24A | 30 mV pk-pk @20MHz bandwidth | 10.5x9x5 | 95 | 56-SMD | $12 | |||
Buck | Vishay | SIC951ED-T1-GE3 | Yes | No? | 4.5V | 20V | 0.3V | 5.5V | 25A | ±1% output voltage accuracy | 10.6x6.5x3 | 69 | 60-PowerBFQFN | $22 | SIC951EVB-A | ||
Buck | Texas Instrument | LMZ31520RLGT | No | No | 3V | 14.5V | 0.6V | 3.6V | 20A | ±1.8% total output voltage variation, 1% output voltage ripple @20MHz bandwidth | 16.2x15.2x5.9 | 246 | 72-BQFN | $20 | GT Readout Platform | LMZ31520EVM-001 | |
Buck | Texas Instrument | LMZ31530RLGT | No | No | 3V | 14.5V | 0.6V | 3.6V | 30A | ±2.0% total output voltage variation, 1% output voltage ripple @20MHz bandwidth | 16.2x15.2x5.9 | 246 | 72-BQFN | $23 | LMZ31530EVM-002 | ||
Buck | Microchip Technology | MIC45212-2YMP-TR | No | No | 4.5V | 26V | 0.8V | 5.5V | 14A | 1% output voltage accuracy | 10x10x4 | 100 | 64-BQFN | $10 | MIC45212-2YMP-EV | ||
Buck | Texas Instruments | TPSM365R6F | No | No | 3V | 65V | 1V | 13V | 0.6A | 3.5x4.5x2 | 16 | 11-PowerFQFN | $4 | Pin compatible with TPSM33625 | TPSM365R6FEVM | ||
Buck | Texas Instruments | TPSM33625 | No | No | 3V | 36V | 1V | 15V | 2.5A | 3.5x4.5x2 | 16 | 11-PowerFQFN | $4 | Pin compatible with TPSM365R6 | TPSM33625FEVM | ||
Buck | Analog Devices Inc. | LTM4675 | Yes | Yes | 4.5V | 17V | 0.5V | 5.5V | 9A x2 | ±0.5% DC output error over temperature, 10 mV pk-pk output voltage ripple | 16x12x3.5 | 192 | 108-BGA | $46 | DC2053A | ||
Buck | Analog Devices Inc. | LTM4676A | Yes | Yes | 4.5V | 26.5V | 0.5V | 5.4V | 13A x2 | ±0.5% DC output error over temperature, 10 mV pk-pk output voltage ripple | 16x16x5 | 256 | 144-BGA | $65 | ePixUHR35kHz - Megapixel Cameras | DC1811B-B | |
Buck | Analog Devices Inc. | LTM4677 | Yes | Yes | 4.5V | 16V | 0.5V | 1.8V | 18A x2 | ±0.5% DC output error over temperature, 10 mV pk-pk output voltage ripple | 16x16x5 | 256 | 144-BGA | $76 | DC2066A | ||
Buck | Analog Devices Inc. | LTM4700 | Yes | Yes | 4.5V | 16V | 0.5V | 1.8V | 50A x2 | ±0.5% DC output error over temperature, 10 mV pk-pk output voltage ripple | 22x15x7.9 | 330 | 330-BGA | $180 | DC2702B-A | ||
Buck | Analog Devices Inc. | LTM4686 | Yes | Yes | 4.5V | 17V | 0.5V | 3.6V | 10A x2 | ±0.5% DC output error over temperature, 10 mV pk-pk output voltage ripple | 16x11.9x1.82 | 190 | 108-BGA | $49 | DC2722A | ||
Buck | Analog Devices Inc. | LTM4664 | Yes | Yes | 30V | 58V | 0.5V | 1.5V | 25A x2 | ±0.5% Output Voltage Accuracy Over Temperature | 16x16x7.72 | 256 | 240-BGA | $85 | Pin compatbile with LTM4664A | DC2672A-A | |
Buck | Analog Devices Inc. | LTM4664A | Yes | Yes | 30V | 58V | 0.5V | 1.2V | 30A x2 | ±0.5% Output Voltage Accuracy Over Temperature | 16x16x7.72 | 256 | 240-BGA | $113 | Pin compatbile with LTM4664A | ||
Buck | Analog Devices Inc. | LTM4668 | No | No | 2.7V | 17V | 0.6V | 1.8V | 1.2A x4 | ±1.5% Total Output Voltage Regulation | 6.25x6.25x2.1 | 39 | 49-BGA | $17 | Pin compatible with LTM4668A | DC2785A-A | |
Buck | Analog Devices Inc. | LTM4668A | No | No | 2.7V | 17V | 0.6V | 5.5V | 1.2A x4 | ±1.5% Total Output Voltage Regulation | 6.25x6.25x2.1 | 39 | 49-BGA | $17 | Pin compatible with LTM4668 | DC2785A-B | |
Buck | Analog Devices Inc. | LTM4655 | No | Yes | 3.1V | 40V | 0.5 | 26.5 | 4A x2 | ±1.67% total dc output voltage error over line, load and temperature | 16×16×5 | 256 | 144-BGA | $40 | Both channels can operate as either positive or negative output independently. | DC2594A | |
Buck | Analog Devices Inc. | LTM4630A | No | No | 4.5V | 18V | 0.6V | 8V | 18A x2 | ±1.5% DC output error over line, load and temperature, 15 mV pk-pk output voltage ripple | 16x16x4.4 | 256 | 144-BGA | $69 | DC2152A | ||
Buck | Analog Devices Inc. | LTM8024 | No | No | 3V | 40V | 0.8V | 8V | 3.5A x2 | 9×11.25×3.32 | 101 | 88-BGA | $23 | DC1868A | |||
Buck | Analog Devices Inc. | LTM8060 | No | No | 3V | 40V | 0.8V | 8V | 3A x4 | 0.05% line regulation, 0.1% load regulation, 10 mV output RMS ripple | 16x11.9x3.5 | 190 | 165-BGA | $34 | ePixUHR35kHz - Megapixel Cameras | DC2820A | |
Buck | Analog Devices Inc. | LTM8065 | No | No | 3.4V | 40V | 0.97V | 18V | 2.5A | 6.25×6.25×2.32 | 39 | 36-BGA | $16 | DC2251A | |||
Buck | Analog Devices Inc. | LTM8071 | No | No | 3.6V | 60V | 0.97V | 15V | 5A | 0.5% line regulation, 10 mV output voltage ripple | 11.3x9x3.5 | 102 | 80-BGA | $34 | DC2387A | ||
Buck | Analog Devices Inc. | LT8638S | No | No | 2.8V | 42V | 0.6V | 42V | 12A | <10 mV pk-pk output ripple | 5x4 | 20+49=69 | 28-QFN | $13 | External inductor needed | DC2929A | |
Buck | Analog Devices Inc. | LTM8063 | No | No | 3.2V | 40V | 0.8V | 15V | 2A | 6.25×4x2.22 | 25 | 28-BGA | $19 | Up to 2.5A Peak Current | DC2494A | ||
Buck | Analog Devices Inc. | LTM8065 | No | No | 3.4V | 40V | 0.97V | 18V | 2.5A | 6.25×6.25x2.32 | 39 | 36-BGA | $17 | Up to 3.5A Peak Current | DC2251A | ||
Buck | Analog Devices Inc. | LTM8073 | No | No | 3.4V | 60V | 0.8V | 15V | 3A | 6.25×9x3.32 | 56 | 48-BGA | $25 | Up to 5A Peak Current | DC2389A | ||
Buck | Analog Devices Inc. | LTM8074 | No | No | 3.2V | 40V | 0.8V | 12V | 1.2A | 4x4x1.82 | 16 | 25-BGA | $11 | Up to 1.75A Peak Current | DC2753A | ||
Buck + LDO | Analog Devices Inc. | LTM8001 | No | No | 6V | 36V | 1.2V/0V | 24V | 1.1A x6 | 90 μVRMS (100Hz to 1MHz) | 15×15×3.42 | 225 | 121-BGA | $41 | One buck convertor and 5 LDOs in one package. 3 of the LDOs are fed by the buck converter, and the other two can be fed by external pin. | DC1818A | |
Buck + LDO | Analog Devices Inc. | LTM8080 | No | No | 3.5V | 40V | 0V | 8V | 0.5A x2 | <1 μVRMS (10Hz to 100kHz) | 9×6.25×3.32 | 56 | 44-BGA | $25 | One buck convertor and 2 LDOs in one package. Internal voltage tracking function to minimize power loss. | ePixUHR35kHz - Megapixel Cameras | DC3071A |
LDO | Analog Devices Inc. | LT3086EFE | No | Yes | 0.4V | 40V | 0.4V | 32V | 2.1A | ±2% tolerance over line, load and temperature, 40 μV RMS output noise (10Hz to 100kHz) | 5x7 | 35 | 16-TSSOP | $9 | GT Readout Platform, SparkPix-IO | DC1729A | |
LDO | Analog Devices Inc. | LT3091EDE | No | Yes | -36V | -1.5V | -32V | 0V | 1.5A | 18 μVRMS output noise (10Hz to 100kHz) | 4x3 | 12 | 14-DFN | $9 | GT Readout Platform | DC2276A | |
LDO | Analog Devices Inc. | LT3045EDD | No | Yes | 1.8V | 20V | 0V | 15V | 0.5A | 0.8 µVRMS output noise (10Hz to 100kHz) | 3x3 | 9 | 10-DFN | $8 | SparkPix-IO, GT Readout Platform, ePixUHR35kHz - Megapixel Cameras | DC2491A | |
LDO | Analog Devices Inc. | LT3070 | No | No | 0.95V | 3V | 0.8V | 1.8V | 5A | ±1% accuracy over line, load and temperature, 25 μV RMS output noise (10Hz to 100kHz) | 4x5 | 20 | 28-QFN | $11 | VIOC1, discrete output voltage settings (50mV increments from 0.8V to 1.8V) and a ±1%, ±3% or ±5% analog adjustment pin. | DC1433A | |
LDO | Analog Devices Inc. | LT3071 | No | Yes | 0.95V | 3V | 0.8V | 1.8V | 5A | ±1% accuracy over line, load and temperature, 25 μV RMS output noise (10Hz to 100kHz) | 4x5 | 20 | 28-QFN | $11 | VIOC1, discrete output voltage settings (50mV increments from 0.8V to 1.8V) and a ±10% analog adjustment pin. | DC1434A | |
LDO | Analog Devices Inc. | LT3073 | No | Yes | 0.6V | 5.5V | 0.5V | 4.2V | 3A | ±1.5% over line, load, and temperature, 1.2 μVRMS output noise (10Hz to 100kHz) | 3x4 | 12 | 22-QFN | $12 | VIOC1, discrete output voltage settings (50mV increments from 0.5V to 1.2V, 100mV increments from 1.2V to 1.8V) → 1.00V, 1.05V, 1.1V, 1.15V, 1.2V, 1.3V, 1.4V. | EVAL-LT3073-AZ | |
LDO | Analog Devices Inc. | LT3078 (not available yet) | No | Yes | 0.6V | 5.5V | 0.5V | 4.2V | 5A | ±1.5% over line, load, and temperature, 1.3 μVRMS output noise (10Hz to 100kHz) | 3x4 | 12 | 22-QFN | ??? | VIOC1, discrete output voltage settings (50mV increments from 0.5V to 1.2V, 100mV increments from 1.2V to 1.8V) → 1.00V, 1.05V, 1.1V, 1.15V, 1.2V, 1.3V, 1.4V. | EVAL-LT3078 | |
LDO | Analog Devices Inc. | LTM4709 | No | Yes | 0.6V | 5.5V | 0.5V | 4.2V | 3A x3 | ±1.5% output voltage regulation over line, load, and temperature, 1.3 μVRMS output noise (10Hz to 100kHz) | 12x6x1.9 | 72 | 98-BGA | $35 | VIOC1, discrete output voltage settings (50mV increments from 0.5V to 1.2V, 100mV increments from 1.2V to 1.8V) → 1.00V, 1.05V, 1.1V, 1.15V, 1.2V, 1.3V, 1.4V. | ePixUHR35kHz - Megapixel Cameras | DC3211A |
Footnotes:
The following ICs can be used together with a power regulator module that does not have PMBus support built-in. These IC's can control, trim and monitor several regulators and exposes a PMBus compatible interface. Note though that most of these have a maximum input voltage of 15 V and could require a separate power supply (something like LTM8074 or TPSM5601R5) that is powered directly from the main input supply to also ensure that the controller is powered up first.
Manufacturer | Part number (Manufacturer link) | # channels | Package | Price (2024) | Note |
---|---|---|---|---|---|
Analog Devices Inc. | LTC2970 | 2 | 4x5 mm (24-QFN) | $11 | Only I2C/SMBUS, not PMBus. |
Analog Devices Inc. | LTC2972 | 2 | 6x7 mm (44-QFN) | $12 | |
Analog Devices Inc. | LTC2977 | 8 | 9×9 mm (64-QFN) | $29 | |
Analog Devices Inc. | LTC2979 | 16 | 12x12 mm (144-BGA) | $32 | Contains two of LTC2977. Can only be powered from 3.3V. |
Analog Devices Inc. | LTC2980 | 16 | 12x12 mm (144-BGA) | $30 | Contains two of LTC2977 |
Analog Devices Inc. | LTC2980-24 | 24 | 8.1x16.9 mm (210-BGA) | ??? | Contains three of LTC2977 |
Analog Devices Inc. | LTC2975 | 4 | 9x9 mm (64-QFN) 6.25×7.5 mm (63-BGA) | $25 | |
Analog Devices Inc. | LTM2987 | 16 | 15×15 mm 144-BGA | $52 | Contains two of LTC2977. μModule version of LTC2979, i.e. has some passives already inside. |