The Enpirion product line has been the "go to" for our DC/DC converter needs for many years. It was first used in the RCE generation 3 development 10+ years ago because of its low PCB footprint area. After the RCE development, we have been using it for other TID-ID related designs (LCLS-II, LCLS DAQ, LDMX, LSST, etc).
Original Enpirion was originally owned by Altera. Later Altera was bought by Intel. In September 2021, Intel announced that it will depreciate their entire "Enpirion" product line with no replacement OPN. The last time to buy was March 18, 2022.
In September 2021, we did a survey of all TID-ID PCB BOMs to identify which ones were using Enpirion product line. After identifying the PCB designs using this DC/DC converter, we contacted all the PCB designers to inform them about the depreciation. We also asked the PCB designers the following questions:
From that questionnaire we have create tables for those 3 category types below.
What if I don't see my PCB design listed below?
If you do NOT see your PCB design listed in the tables below, then your PCB design does NOT use Enpirion product line and not affected by this depreciation.
# | Name w/ Hyperlink | Design Engineer | Project Manager | Experiment |
---|---|---|---|---|
1 | SIM: LaserLocker Digital board | Larry Ruckman | Bo Hong | LCLS-I |
2 | ATCA AMC Carrier Gen2 | Larry Ruckman | SMURF | SMURF |
3 | LSST: AC Filter Relay Board | Mark Freytag | Gregg Thayer | LSST |
4 | LSST: Hybrid RTM | Ben Reese | Gregg Thayer | LSST |
5 | LSST: Hybrid RTM Daughterboard | Ben Reese | Gregg Thayer | LSST |
6 | LSST: SCI Array Board | Mark Freytag | Gregg Thayer | LSST |
7 | LSST: DAQ FPGA ATCA-RTM | Gregg Thayer | Gregg Thayer | LSST |
8 | LSST: DAQ SSD ATCA-RTM | Gregg Thayer | Gregg Thayer | LSST |
9 | LSST: REB TRANSITION | Mark Freytag | Gregg Thayer | LSST |
10 | LSST: PROTOTYPE WGREB DCBS | Mark Freytag | Gregg Thayer | LSST |
11 | LSST: GREB Production Board | Mark Freytag | Gregg Thayer | LSST |
12 | LSST: WREB Production Board | Mark Freytag | Gregg Thayer | LSST |
13 | LSST: REB power supply | Leonid Sapozhniko | Gregg Thayer | LSST |
14 | LSST: RCE: COB | Ryan Herbst | Gregg Thayer | LSST |
15 | LSST: RCE: DPM | Ryan Herbst | Gregg Thayer | LSST |
16 | LSST: RCE: DTM | Ryan Herbst | Gregg Thayer | LSST |
17 | LSST: RCE: GEN3 SFP RTM | Ryan Herbst | Gregg Thayer | LSST |
18 | LSST: RCE: GEN3 RTM Mezzanine Board | Ryan Herbst | Gregg Thayer | LSST |
# | Name w/ Hyperlink | Design Engineer | Experiment |
---|---|---|---|
1 | PGP GEN3 Card | Larry Ruckman | LCLS DAQ |
2 | ATLAS: ALTIROC FPGA Board | Larry Ruckman | ATLAS |
3 | ATLAS: CHESS2 Digital Carrier Board | Larry Ruckman | ATLAS |
4 | ATLAS: Link Aggregator | Larry Ruckman | ATLAS |
5 | ATLAS: RD53 FPGA board | Larry Ruckman | ATLAS |
6 | LBNE RTM | Larry Ruckman | DUNE |
7 | ATLAS: HSIO_II | Mark Freytag | ATLAS |
8 | LZ Test Stand Digitizer Board | Larry Ruckman | LZ |
9 | LZ Test Stand Front End Board | Larry Ruckman | LZ |
10 | Darkside Front End Development Board | Larry Ruckman | LZ |
11 | KPIX DESY Tracker DAQ | Ben Reese | KPIX |
12 | EPIX HR Prototype Analog Board | Dionisio Doering | EPIX |
13 | ePixM Shingled Concentrator Board | Dionisio Doering | EPIX |
14 | ePixM Shingled Mother Board | Dionisio Doering | EPIX |
15 | Scorpius Pulser Transmitter Test Board | Leonid Sapozhniko | Detector R&D |
16 | LCLS-II: Sub-Booster Trigger Board | Ben Reese | LCLS-II |
17 | LCLS-II: Copper Linac to Soft (CLTS) RTM | Jeff Olsen | LCLS-II |
18 | LSST: GREB Engineering Model | Mark Freytag | LSST |
19 | LSST: WREB Engineering Model | Mark Freytag | LSST |
# | Enpirion Part# | Vin(max) | Vout(range) | Iout(max) | Replacment Part# |
---|---|---|---|---|---|
1 | EN5311QI | 5.5V | 0.6~4.9V | 1A | |
2 | EN5322QI | 2A | |||
3 | EN6337QI | 3A | |||
4 | EN6347QI | 4A | |||
5 | EN6360QI | 8A | |||
6 | EN63A0QI | 12A | |||
7 | EN2340QI | 14V | 0.75 ~ 5V | 4A | |
8 | EN2390QI | 9A | |||
9 | EM2120H01QI | 16V | 1.325 ~ 5V | 20A | |
10 | EM2120L01QI | 0.7 ~ 1.325V | |||
11 | EM2130L02QI | 1.325 ~ 5V | 30A | TI LMZ31530 | |
12 | EM2140P01QI | 0.7 ~ 1.325V | 40A | TBD | |
13 | EM2260P01QI | 0.5 ~ 1.3V | 60A | TBD | |
14 | EM2280P01QI | 80A | TBD |