This page gives an overview over the simulation and reconstruction status of the DBD production for the SiD detector.

A selection of files can be made through the dirac file catalog web frontend.
The status and further details of the production can be found in the separate dirac job and production monitoring page.

The following submission scripts were used to generate all the data samples:

Beam-related backgrounds

These samples have been simulated with a Gaussian smearing of the particle origin in z. The width is 225um.

Each file contains sufficient events to be overlaid on 100 signal events.


Process Name

ProdID
Simulation p80m20

ProdID
Simulation m80p20

aa_lowpt (1TeV)

1766

1767

eepairs (1TeV)

1

2

aa_lowpt (500GeV)

1878

1881

Physics Samples at 1 TeV

Extraneous Muon Events

In addition to the physics processes, a fraction of files contain "events" only consisting of single muon with the properties

Quantity

Value

energy

5.1057836183170489 GeV

px

0.035740192979574203 GeV

py

5.1045651435852051 GeV

pz

0

charge

-1

origin

(0, 0, 0)

In a physics analysis, events containing such a muon must be removed from the data sample. This does not bias the event selection and does not affect the computation of the luminosity.

The files are available on the grid under /ilc/prod/ilc/sid/1000_p80m20/ and /ilc/prod/ilc/sid/1000_m80p20/. Append the process name to the path.

 

ProdID

ProdID

ProdID

ProdID

Process Name

Simulation p80m20

Simulation m80p20

Reconstruction p80m20

Reconstruction m80p20

ttbb-ln4q-all

1660

1676

1791 1962

1790 1963

ttz-6q-all

1664

1674

1792 1964

1793 1965

6f_ttbar

1662

1672

1794 1966

1795 1967

ttbb-6q-all

1666

1670

1796 1968

1797 1969

ttz-ln4q-all

1668

1678

1798 1970

1799 1971

tth-6q-hbb

1693

1690

1800 1906

1801 1933

tth-6q-hnonbb

1696

1699

1802 1934

1803 1935

tth-2l2nbb-hbb

1720

1723

1804 1936

1805 1937

tth-2l2nbb-hnonbb

1702

1705

1806 1938

1807 1939

tth-ln4q-hbb

1708

1711

1808 1940

1811 1943

tth-ln4q-hnonbb

1714

1717

1809 1941

1810 1942

evW_eeZ_vvZ_semileptonic

1682

1680

1814 1945

1815 1946

higgs_ffh_nomu

1729

1726

1812 1944

1813 1948

eeZ_vvZ_leptonic

1735

1732

1816 1949

1817 1950

4f_WW

1738

1741

1818 1952

1819 1953

all_other_SM_background

1783

1771

1820 1960

1821 1961

ffh_mumu

1823

1826

1862 1972

1863 1973

Physics Samples at 500 GeV

There are some data sets at 500 GeV that are being regenerated for the DBD. These files are at /ilc/prod/ilc/sid/500_p80m20/ and /ilc/prod/ilc/sid/500_m80p20/.

 

ProdID

ProdID

ProdID

ProdID

Process Name

Simulation p80m20

Simulation m80p20

Reconstruction p80m20

Reconstruction m80p20

6f_ttbar_mt173p5

1857

1860

1947

1951

6f_ttbar_mt174p0

1851

1854

1974

1975

all_SM_background

1958

1955

1976

1977

Physics Samples at 250 GeV

 

ProdID

ProdID

ProdID

ProdID

Process Name

Simulation p80m20

Simulation m80p20

Reconstruction p80m20

Reconstruction m80p20

lepton_SM_background

1989

1986

2179

2180

e2e2h_mh125p00

2062

1992

2081

1994

e2e2h_mh124p50

2066

2068

2082

2160

e2e2h_mh124p75

2072

2070

2173

2174

e2e2h_mh125p25

2074

2076

2175

2176

e2e2h_mh125p50

2078

2080

2177

2178

  • No labels