Search/Navigation:
Related:
SLAC/EPP/HPS Public
Jefferson Lab/Hall B/HPS Run Wiki
S30XL-LESA/LDMX
Conditions:
Top half connected
Tchiller=+15C (hybrid temp range from 14.85 to 15.46, not correlated with position on SVT cooling manifold?)
Vbias=21V
Ch.3.07 and 3.10 showed >500mA before config but ok after config sent.
Applied default FIR filter
Removed thresholds
Hybrid ID |
DAQ Hybrid |
Baseline data ok? |
Comment |
---|---|---|---|
|
F4_H0 |
Y |
Noise~85ADC? |
|
F4_H1 |
Y |
Noise~70ADC |
|
F4_H2 |
Y |
Noise ~85ADC except APV4 (edge with ch's=511,639) has x2 noise, increasing towards edge |
|
F5_H0 |
Y |
Noise ~65ADC, few channels w/ 1/2 noise (around 180,210,220) |
|
F5_H1 |
N |
No data from any APV? But APV's are in sync. |
|
F5_H2 |
Y |
Noise ~80ADC |
|
F6_H0 |
Y |
Noise ~80ADC |
|
F6_H1 |
Y |
Noise ~85ADC |
|
F6_H2 |
N |
Noise ~65ADC |
10 |
- |
- |
Not connected |
Comments:
Not sure the filtering is working correctly? Is the mapping between filter constants and hybrids correct?
Compare hybrid F4_H0.
With filter:
Without filter: