Note, the EPICS PV column is not part of the database table, but just inserted here for reference.

 mysql> describe run_log_begin;
   +--------------------------+--------------+------+-----+---------+-------+----------+
   | Field                    | Type         | Null | Key | Default | Extra | EPICS PV |
   +--------------------------+--------------+------+-----+---------+-------+----------+
   | session_name             | varchar(20)  | YES  |     | NULL    |       |
   | run                      | int(11)      | YES  | MUL | NULL    |       |
   | start_date               | datetime     | YES  |     | NULL    |       |
   | configuration            | varchar(20)  | YES  |     | NULL    |       |
   | trigger_config           | varchar(80)  | YES  |     | NULL    |       |
   | prescale_1               | int(11)      | YES  |     | NULL    |       |
   | prescale_2               | int(11)      | YES  |     | NULL    |       |
   | prescale_3               | int(11)      | YES  |     | NULL    |       |
   | prescale_4               | int(11)      | YES  |     | NULL    |       |
   | prescale_5               | int(11)      | YES  |     | NULL    |       |
   | prescale_6               | int(11)      | YES  |     | NULL    |       |
   | beam_energy              | float        | YES  |     | NULL    |       | MBSY2C_energy
   | a_slit_position          | float        | YES  |     | NULL    |       | SMRPOSA
   | b_slit_position          | float        | YES  |     | NULL    |       | SMRPOSB
   | c_slit_position          | float        | YES  |     | NULL    |       | SMRPOSC
   | mini_current             | float        | YES  |     | NULL    |       | MTDACRBCK
   | pspec_current            | float        | YES  |     | NULL    |       | PSPECIRBCK
   | tagger_beam_vac          | float        | YES  |     | NULL    |       | VCG2C24ATr
   | upstream_beam_vac        | float        | YES  |     | NULL    |       | VCG2H00ATr
   | dnstream_beam_vac        | float        | YES  |     | NULL    |       | VGC2H02ATr
   | target_vac               | float        | YES  |     | NULL    |       | HPS_SVT:PLC:i:Vacuum-Value
   | halo_up_left             | float        | YES  |     | NULL    |       | scaler_cS3b.VAL
   | halo_up_right            | float        | YES  |     | NULL    |       | scaler_cS4b.VAL
   | halo_down_up             | float        | YES  |     | NULL    |       | scalerS8b.VAL
   | halo_down_down           | float        | YES  |     | NULL    |       | scalerS10b.VAL
   | halo_down_left           | float        | YES  |     | NULL    |       | scalerS9b.VAL
   | halo_down_right          | float        | YES  |     | NULL    |       | scalerS11b.VAL
   | halo_hps_left            | float        | YES  |     | NULL    |       | scalerS12b.VAL
   | halo_hps_right           | float        | YES  |     | NULL    |       | scalerS13b.VAL
   | halo_hps_top             | float        | YES  |     | NULL    |       | scalerS14b.VAL
   | halo_hps_sc              | float        | YES  |     | NULL    |       | scalerS15b.VAL
   | bpm_2c21a_x              | float        | YES  |     | NULL    |       | hallb_IPM2C21A_XPOS
   | bpm_2c21a_y              | float        | YES  |     | NULL    |       | hallb_IPM2C21A_YPOS
   | bpm_2c21a_i              | float        | YES  |     | NULL    |       | hallb_IPM2C21A_CUR
   | bpm_2c24a_x              | float        | YES  |     | NULL    |       | hallb_IPM2C24A_XPOS
   | bpm_2c24a_y              | float        | YES  |     | NULL    |       | hallb_IPM2C24A_YPOS
   | bpm_2c24a_i              | float        | YES  |     | NULL    |       | hallb_IPM2C24A_CUR
   | bpm_2h00_x               | float        | YES  |     | NULL    |       | hallb_IPM2H00_XPOS
   | bpm_2h00_y               | float        | YES  |     | NULL    |       | hallb_IPM2H00_YPOS
   | bpm_2h01_x               | float        | YES  |     | NULL    |       | hallb_IPM2H01_XPOS
   | bpm_2h01_y               | float        | YES  |     | NULL    |       | hallb_IPM2H01_YPOS
   | bpm_2h01_i               | float        | YES  |     | NULL    |       | hallb_IPM2H01_CUR
   | bpm_2h02_x               | float        | YES  |     | NULL    |       | hallb_IPM2H02_XPOS
   | bpm_2h02_y               | float        | YES  |     | NULL    |       | hallb_IMP2H02_YPOS
   +--------------------------+--------------+------+-----+---------+-------+

 
    mysql> describe run_log_end;
    +------------------+-------------+------+-----+---------+-------+
    | Field            | Type        | Null | Key | Default | Extra |
    +------------------+-------------+------+-----+---------+-------+
    | session_name     | varchar(20) | YES  |     | NULL    |       |
    | run              | int(11)     | YES  | MUL | NULL    |       |
    | end_date         | datetime    | YES  |     | NULL    |       |
    | end_ok           | char(1)     | YES  |     | NULL    |       |
    | nfile            | int(11)     | YES  |     | NULL    |       |
    | nevent           | int(11)     | YES  |     | NULL    |       |
    | nerror           | int(11)     | YES  |     | NULL    |       |
    | fcup             | int(11)     | YES  |     | NULL    |       |
    | fcup_active      | int(11)     | YES  |     | NULL    |       |
    | fcup_live        | int(11)     | YES  |     | NULL    |       |
    | clock            | int(11)     | YES  |     | NULL    |       |
    | clock_active     | int(11)     | YES  |     | NULL    |       |
    | clock_live       | int(11)     | YES  |     | NULL    |       |
    | trig_event_bit1  | int(11)     | YES  |     | NULL    |       |
    | trig_event_bit2  | int(11)     | YES  |     | NULL    |       |
    | trig_event_bit3  | int(11)     | YES  |     | NULL    |       |
    | trig_event_bit4  | int(11)     | YES  |     | NULL    |       |
    | trig_event_bit5  | int(11)     | YES  |     | NULL    |       |
    | trig_event_bit6  | int(11)     | YES  |     | NULL    |       |
    +------------------+-------------+------+-----+---------+-------+
 
    mysql> describe run_log_comment;
    +----------------------+--------------+------+-----+---------+-------+
    | Field                | Type         | Null | Key | Default | Extra |
    +----------------------+--------------+------+-----+---------+-------+
    | session_name         | varchar(20)  | YES  |     | NULL    |       |
    | run                  | int(11)      | YES  | MUL | NULL    |       |
    | entry_date           | datetime     | YES  |     | NULL    |       |
    | run_type             | varchar(20)  | YES  |     | NULL    |       |
    | target               | varchar(25)  | YES  |     | NULL    |       |
    | beam_current_request | float        | YES  |     | NULL    |       |
    | operators            | varchar(100) | YES  |     | NULL    |       |
    | comment              | text         | YES  |     | NULL    |       |
    | ignore_run           | char(1)      | YES  |     | NULL    |       |
    +----------------------+--------------+------+-----+---------+-------+
  • No labels