Copy new SD card image.
Use hps_dpm.bin for DPM and DTM hps_dtm.bin
dd if=hps_dpm.bin of=/dev/disk2 bs=1000000
There should be multiple partitions available for mounting.
RTEMS RTEMSAPP LINUX SCRATCH BOOT
Mount the first "boot" partition. E.g.:
mount /dev/disk2s1 /mnt/sdcard
After it's content of first partition on sd card image:
boot.bin fpga.bit readme.bot uboot.env uboot_linux.env uboot_ramdisk.env uboot_rce.env (?) version.txt
To set the archLinux environment for a given dpm/dtm host overwrite two boot environment files. To create a boot card for e.g. dpm11:
cp dpm11.env /mnt/sdcard/uboot.env cp dpm11.env /mnt/sdcard/uboot_linux.env
Figure out which RCE the newly created SD card correspond to: see COB Layout.
COB Startup Checks
COB status:
Identify RCEs from the front panel by noting the cycling patterns that are printed.
We are looking for “not ready”, e.g. "dpmp1-rce2 - not ready".
RTM status:
General:
/usr/clas12/release/1.3.0/slac_svt/svtdaq/daq/rceScripts/setup_linux.sh 'hostname'
$ssh root@'hostname' $systemctl enable rce_start