First, the event builder, event recorder and ET ring can be started by issuing the following commands from a terminal:
cd /u1/coda_rth ./start_coda_xterm.csh
This will open a dedicated (blue) xterm for each of the processes above. It will also open a terminal with a connection to the TI. This will require a password which can be retrieved from one of the SVT DAQ experts.
Note
Running the script start_coda_xterm.csh is equivalent to running the following commands with some additional options:
cd /u1/coda_rth sudo ./start_eb sudo ./start_er sudo ./start_et
Once the event builder, event recorder and ET ring have started up successfully, the run control can be started as follows:
sudo tcsh su -l **** (DAQ expert user name) cd /u1/coda_rth/ ./start_coda_xterm_rc.csh
Note
Running the script start_coda_xterm_rc.csh is equivalent to running the following command with some additional options:
cd /u1/coda_rth ./start_rc
When running using Sergey's binaries, the symbolic link /usr/local needs to be pointing to /usr/new_local. This symbolic link is destroyed every night by Taylor so it needs to be set once daily.
Connect to DTM/DPM and start ROCs.
There is a script that pops up all windows in xterms:
$ cd /u1/coda_rth
$ ./start_rce.csh
$ cd /u1/daq
$ source setup_env.csh
$ ./rceScripts/connect_host <slot> <?> <?> (FIX NAMES OF ID's)
$ /mnt/host/coda/run_roc
Start rce GUI if not running:
$ cd /u1/daq
$ ./rceScripts/start_gui.csh
If it fails to connect check that server is running on dpm7 and restart if needed
$ ssh dpm7
$ cd /mnt/host/daq
$ ./rceScripts/start_server.csh
Click 'Connect' on RC GUI. Click 'Configure' then select '8rces' as run type. Click 'Config' and select '/mnt/host/coda/svtrce0.cnf'. Click 'OK'.
At the moment, during the 'Configure' stage, the configuration file svtrce0.cnf is being overwritten. In order for things to work properly, the overwritten file needs to be replaced with a backup after the configuration has taken place. To do this, issue the following command in a terminal:
sudo cp /u1/cob_nfs/host/coda/svtrce0.cnf.save /u1/cob_nfs/host/coda/svtrce0.cnf
Click 'Download'. 'Prestart' button appears if things worked.
Go to TI and Reset (but don't start sending triggers)
Click 'Prestart'.
Click 'Go'.
Go to TI and start sending triggers.
$ cd /u1/daq & source setup_env.csh
$ ./rceScripts/connect_ti.csh (pw ask Pelle/Ryan/Ben)
$ cd ti/test
$ ./tiLibTest
TBI
Host | slot | ? | ? |
---|---|---|---|
dtm | 4 | 1 | 0 |
dpm0 | 1 | 0 | 0 |
1 | 0 | 2 | |
1 | 1 | 0 | |
1 | 1 | 2 | |
1 | 2 | 0 | |
1 | 2 | 2 | |
1 | 3 | 0 | |
dpm7 | 1 | 3 | 2 |