Search/Navigation:
Related:
SLAC/EPP/HPS Public
Jefferson Lab/Hall B/HPS Run Wiki
S30XL-LESA/LDMX
Git tag: v12_13_2018
In this table summarized various pass related attributes.
ATTRIBUTE | Value |
PASS | pass2 |
DETECTOR | HPS-PhysicsRun2016-Pass2 |
FIELDMAP | 209acm2_5kg_corrected_unfolded_scaled_1.04545_v4.dat |
TAPETOPDIR | /mss/hallb/hps/physrun2016 |
DISKTOPDIR | /work/hallb/hps/data/physrun2016 |
GROUPTOPDIR | /group/hps/production/data/PhysRun2016 |
RELEASE | v12_13_18 |
PREFIX | hps_00 |
JAVA | /apps/scicomp/java/jdk1.8/bin/java |
SERIALGC | -XX:+UseSerialGC |
JAR | /group/hps/hps_soft/hps-java/hps-distribution-v11_18_18-bin.jar |
JAR_OPTS | -DdisableSvtAlignmentConstants |
DST_SETUP | /u/group/hps/hps_soft/setup_dst.csh |
DSTMAKER | /u/group/hps/hps_soft/hps-dst/centos7-64_gcc4pt9pt2/bin/dst_maker |
HEAPSET | -Xmx1400m |
BLINDED | 1 |
RECON_STEER | /org/hps/steering/recon/PhysicsRun2016FullRecon.lcsim |
PULSER_STEER | /org/hps/steering/production/PulserTriggerFilter.lcsim |
S0_STEER | /org/hps/steering/production/Single0TriggerFilter.lcsim |
S1_STEER | /org/hps/steering/production/Single1TriggerFilter.lcsim |
MOLLER_STEER | /org/hps/steering/production/MollerSkim.lcsim |
V0_STEER | /org/hps/steering/production/V0Skim.lcsim |
NTUPLE_STEER | /org/hps/steering/analysis/MakeTuples2016.lcsim |
Exceptions:
about 23% of jobs failed because of "Error writing LCIO file" exception caused by "No space left on device"
An example:
2018-12-15 07:28:36 [INFO] org.lcsim.job.EventPrintLoopAdapter recordSupplied :: event: 55082949; time: 1461394849551037316; seq: 375000
Exception in thread "main" java.lang.RuntimeException: Error writing LCIO file
at org.lcsim.util.loop.LCIODriver.process(LCIODriver.java:116)
at org.lcsim.util.Driver.doProcess(Driver.java:261)
at org.lcsim.util.Driver.processChildren(Driver.java:271)
at org.lcsim.util.Driver.process(Driver.java:187)
at org.lcsim.util.DriverAdapter.recordSupplied(DriverAdapter.java:74)
at org.lcsim.job.JobControlManager.processEvent(JobControlManager.java:819)
at org.hps.evio.EvioToLcio.run(EvioToLcio.java:618)
at org.hps.evio.EvioToLcio.main(EvioToLcio.java:92)
Caused by: java.io.IOException: No space left on device
at java.io.FileOutputStream.writeBytes(Native Method)
at java.io.FileOutputStream.write(FileOutputStream.java:315)
at hep.io.xdr.XDROutputStream$CountedOutputStream.write(XDROutputStream.java:103)
at java.io.DataOutputStream.write(DataOutputStream.javaError in <TBranchElement::Fill>: Failed filling branch:tracks.fs_particle, nbytes=-1
- Some fles have this exception but this is not fatal exception, i.e. reconstruction is not stopped
2018-12-15 07:20:26 [INFO] org.hps.evio.AugmentedSvtEvioReader processSvtHeaders :: Caught 5 SvtEvioHeaderExceptions for event 17654220 of 4 types: SvtEvioHeaderMultisampleErrorBitException SvtEvioHeaderApvBufferAddressException SvtEvioHeaderApvFrameCountException SvtEvioHeaderApvReadErrorException
Files from the run 7988 show the following exception, NOTE this exception happens only for files from the run 7988
hps_007988.0_v11_18_18_Recon.err:java.lang.NumberFormatException: For input string: "18GTP_CLUSTER_PULSE_COIN"
hps_007988.0_v11_18_18_Recon.err: at java.lang.NumberFormatException.forInputString(NumberFormatException.java:65)
Beam Positions
Target Position (-4.3 mm)