Search/Navigation:
Related:
SLAC/EPP/HPS Public
Jefferson Lab/Hall B/HPS Run Wiki
S30XL-LESA/LDMX
Collection Name | Type | Class Where Filled | Description |
---|---|---|---|
EcalHits | SimCalorimeterHit | slic | MC ECal energy deposition |
EcalReadoutHits | RawCalorimeterHit | evio.ECalEvioReader (data) readout.ecal.FADCEcalReadoutDriver (MC) | ECal Hits in ADC counts |
EcalCalHits | CalorimeterHit | recon.ecal.EcalRawConverterDriver | Calibrated ECal Hits |
EcalClusters | Cluster | recon.ecal.EcalClusterICBasic | ECal Clusters |
TrackerHits | SimTrackerHit | slic | MC Si sensor energy deposition |
SVTRawTrackerHits | RawTrackerHit | evio.ECalEvioReader (data) readout.svt.SimpleSvtReadout (MC) | Si sensor single strip hit information |
SVTTrueHitRelations | LCRelation | readout.svt.SimpleSvtReadout | relation between SVTRawTrackerHits and TrackerHits (for MC events) |
SVTShapeFitParameters | GenericObject | recon.tracking.RawTrackerHitFitterDriver | result of the ADC vs sample # fit |
SVTFittedRawTrackerHits | LCRelation | recon.tracking.RawTrackerHitFitterDriver | relation between SVTRawTrackerHits and SVTShapeFitParameters |
StripClusterer_SiTrackerHitStrip1D | TrackerHit | recon.tracking.DataTrackerHitDriver | 1D Si strip clusters |
HelicalTrackHits | TrackerHit | recon.tracking.HelicalTrackHitDriver | 3D SVT hits combining StripClusterer_SiTrackerHitStrip1D hits in axial/stereo layers |
HelicalTrackHitRelations | LCRelation | recon.tracking.HelicalTrackHitDriver | relation between HelicalTrackHits and StripClusterer_SiTrackerHitStrip1D |
HelicalTrackHitMCRelations | LCRelation | recon.tracking.HelicalTrackHitDriver | relation between HelicalTrackHits and MCParticles |
RotatedHelicalTrackHits | TrackerHit | recon.tracking.HelicalTrackHitDriver | same as HelicalTrackHits but rotated into SeedTracker tracking frame (x->y,y->z,z->x) |
RotatedHelicalTrackHitRelations | LCRelation | recon.tracking.HelicalTrackHitDriver | .... but rotated into SeedTracker tracking frame (x->y,y->z,z->x) |
RotatedHelicalTrackHitMCRelations | LCRelation | recon.tracking.HelicalTrackHitDriver | .... but rotated into SeedTracker tracking frame (x->y,y->z,z->x) |
MatchedTracks | Track | recon.tracking.TrackerReconDriver | tracks found in the SVT with (d0,phi,omega,tanlambda,z0) parameters |
FinalStateParticles | ReconstructedParticle | recon.particle.HpsReconParticleDriver | the list of final state particles (electrons, positrons, photons) with 4-momenta. |
UnconstrainedV0Candidates | ReconstructedParticle | recon.particle.HpsReconParticleDriver | electron-positron pairs with vertex (unconstrained) |
BeamspotConstrainedV0Candidates | ReconstructedParticle | recon.particle.HpsReconParticleDriver | electron-positron pairs with vertex/momentum required to point back to beamspot at target |
TargetConstrainedV0Candidates | ReconstructedParticle | recon.particle.HpsReconParticleDriver | electron-positron pairs with the vertex z fixed to the target position and the (x,y) constrained to beamspot |
MCParticle | MCParticle | slic | list of MC generated particles; only includes beam electron info from bunch containing embedded event |
FPGAData | GenericObject | SVT hybrid information (e.g. temperature)...anything else? | |
TriggerBank | GenericObject | trigger information for the event | |
ReadoutTimestamps | GenericObject | event timestamp | |
GBL***** | ---------- | collections used for Generalized Broken Line track fitting/alignment work (standalone) | |
ConfirmedMCParticles | MCParticle | I don't think this is filled anymore and isn't necessary | |
SeededMCParticles | MCParticle | I don't think this is filled anymore and isn't necessary |