Search/Navigation:
Related:
SLAC/EPP/HPS Public
Jefferson Lab/Hall B/HPS Run Wiki
S30XL-LESA/LDMX
Confluence will be down for maintenance June 14 2024 at 6AM PT.
Hybrid Mez Board | Voltage (V) | Current (uA) |
---|---|---|
L1 | 2000 | 0 |
L2 | 2000 | 0 |
L3 | 2000 | 0 |
L4 | 2000 | 2.2* |
* Current increased linearly with voltage.
Hybrid Mez Board | Voltage (V) | Current (uA) |
---|---|---|
L1 | 2000 | 0 |
L2 | 2000 | 0 |
L3 | 2000 | 0 |
L4 | 2000 | 0 |
FEB Channel (Hybrid Mez Board) | @ FEB (V) | @ Hybrid (V) | Voltage Drop (mV) | Current (mA) |
---|---|---|---|---|
0 (L1) | 2.551 | 2.468 | 83 | 284 |
1 (L2) | 2.517 | 2.445 | 72 | 282.5 |
2 (L4) | 2.525 | 2.436 | 89 | 281.5 |
3 (L3) | 2.526 | 2.449 | 77 | 281.5 |
Trim set to 220 | ||||
2 (L4) | 2.832 | 2.707 | 125 | 317.5 |
FEB Channel (Hybrid Mez Board) | @ FEB (V) | @ Hybrid (V) | Voltage Drop (mV) | Current (mA) |
---|---|---|---|---|
0 (L1) | 2.503 | 2.459 | 44 | 325.15 |
1 (L2) | 2.533 | 2.515 | 43 | 331 |
2 (L4) | 2.525 | 2.481 | 44 | 325 |
3 (L3) | 2.538 | 2.484 | 54 | 318.5 |
Trim set to 220 | ||||
2 (L4) | 2.83 | 2.703 | 127 | 367 |
FEB Channel (Hybrid Mez Board) | @ FEB (V) | @ Hybrid (V) | Voltage Drop (mV) | Current (mA) |
---|---|---|---|---|
0 (L1) | 1.253 | 1.24 | 13 | 265 |
1 (L2) | 1.256 | 1.236 | 20 | 274.5 |
2 (L4) | 1.254 | 1.233 | 21 | 275.5 |
3 (L3) | 1.259 | 1.239 | 20 | 273.5 |
Trim set to 220 | ||||
2 (L4) | 1.41 | 1.293 | 117 | 292 |