Search/Navigation:
Related:
SLAC/EPP
/HPS Public
Jefferson Lab/Hall B
/HPS Run Wiki
S30XL-LESA/LDMX
Crossover Board Slot | Voltage (V) | Current (uA) |
---|---|---|
J1 | 2000 | 0 |
J2 | 2000 | 0 |
J3 | 2000 | 0 |
J4 | 2000 | 0 |
FEB Channel (Crossover Board Slot) | @ FEB (V) | @ Hybrid (V) | Voltage Drop (mV) | Current (mA) |
---|---|---|---|---|
0 (J1) | 2.551 | 2.450 | 101 | 283.5 |
1 (J2) | 2.517 | 2.417 | 100 | 279.5 |
2 (J3) | 2.525 | 2.419 | 106 | 279.5 |
3 (J4) | 2.526 | 2.422 | 104 | 280.5 |
Trim set to 220 | ||||
3 (J4) | 2.833 | 2.718 | 115 | 316.5 |
FEB Channel (Hybrid Mez Board) | @ FEB (V) | @ Hybrid (V) | Voltage Drop (mV) | Current (mA) |
---|---|---|---|---|
0 (L1) | 2.503 | 2.396 | 107 | 308 |
1 (L2) | 2.544 | 2.436 | 108 | 314 |
2 (L4) | 2.528 | 2.414 | 114 | 320.5 |
3 (L3) | 2.524 | 2.412 | 112 | 309 |
Trim set to 220 | ||||
2 (L4) | 2.827 | 2.713 | 114 | 333 |
FEB Channel (Hybrid Mez Board) | @ FEB (V) | @ Hybrid (V) | Voltage Drop (mV) | Current (mA) |
---|---|---|---|---|
0 (L1) | 1.253 | 1.15 | 103 | 273 |
1 (L2) | 1.249 | 1.15 | 99 | 278.5 |
2 (L4) | 1.247 | 1.143 | 104 | 276.5 |
3 (L3) | 1.253 | 1.15 | 103 | 274.5 |
Trim set to 220 | ||||
2 (L4) | 1.417 | 1.301 | 116 | 292 |