Log into 'clonioc4' (requires access through gateway).
ssh hpsrun@clonioc1 hps_epics dev # pull up the screens that are relevant
Log into 'clonioc1' (requires access through gateway).
ssh clonioc1 cd /usr/clas12/hps/dev/ source .setup-hps # Use procServMgr to control the IOC procServMgr -p /usr/clas12/hps/dev/apps/iocBoot -i iochvCaen [status|start|stop] # Monitor output (to check if commands get through the IOC for example) telnet localhost port # you can find the 'port' from the status command above # while in monitor mode: # If you type 'Cntrl-X' the IOC will stop and restart automatically # You can type 'Cntr-]' to get telnet prompt (and e.g. 'quit' to exit form there).
Log into 'clonioc4' (requires access through gateway).
ssh epics@clonioc4 #default passw cd /usr/clas12/hps/dev/ source .setup-hps # Use procServMgr to control the IOC procServMgr -p /usr/clas12/hps/dev/apps/iocBoot [-i IOC_NAME] [status|start|stop] # Examples: # start/stop/status for all SVT DAQ IOCs: procServMgr -p /usr/clas12/hps/dev/apps/iocBoot status/start/stop # Control DPMIOC only: procServMgr -p /usr/clas12/hps/dev/apps/iocBoot status/start/stop -i iocsvtDaq status/start/stop # Data DPM "X" (X=0-13) IOC only: procServMgr -p /usr/clas12/hps/dev/apps/iocBoot status/start/stop -i iocsvtDaqDpmX status/start/stop # Bring up the IOC stdout for all or individual SVT DAQ IOCs cd /usr/clas12/hps/dev/apps/svtDaqApp/scripts ./start_svt_mon.py -h [dpmX|dtmY|cntrldpm] # 'X'=0-13 and 'Y'=0-1
If everything fails try to use the below standard procServMgr scripts:
procServMgr -p /usr/clas12/hps/dev/apps/iocBoot status/start/stop
If the IOC refuses to stop or start, the process might be stuck and you manually have to kill the IOCs before you restart.
If that fails, call Pelle.
NOT USED FOR THE MOMENT
Access IOC from clonioc1:
telnet localhost 20006 # iochvCaen telnet localhost 20007 # iocsvtDaq
Control IOC from clonioc1:
Ctrl+] to exit #(type quit in terminal) Ctrl+x to reboot
ProcServer commands
The path has to be included to override the production default. So it's a bit cumbersome, but you can put the lines in a local script.
procServMgr -p /usr/clas12/hps/dev/apps/iocBoot -i iocsvtDaq stop procServMgr -p /usr/clas12/hps/dev/apps/iocBoot -i iocsvtDaq start procServMgr -p /usr/clas12/hps/dev/apps/iocBoot -i iocsvtDaq status # show all iocs procServMgr -p /usr/clas12/hps/dev/apps/iocBoot status
Development tree on clonioc1:
cd /usr/clas12/hps/dev # contains: # apps/hvCaenApp, apps/iocBoot/iochvCaen # apps/svtDaqApp, apps/iocBoot/iocsvtDaq # drivers/LVMPOD