To control the pulser on the TI master use the following commands:
To monitor trigger rates with strip charts open /home/hpsrun/trigratecharts.xml
HPSTRIGSC_5: gated pulser trigger rate
HPSTRIGSC_0_PRE: gated single0 trigger rate
Change pulser period to e.g. 100Hz:
tcpClient hps11 'sspPulserSetup(10,100.0,0.5,0xFFFFFFFF)'
Change block level to e.g. 40:
tcpClient hps11 'tiSetBlockLevel(40)'
Change prescale to e.g. 15:
tcpClient hps11 'tiSetInputPrescale(1,15)'
tcpClient hps11 tiStatus()
hps3_start
connect, configure, run type, prestart, Go
If mistake - cancel, reset
roc_xterms_start or hps/hpsRocStart.sh
hps/hpsRocRebootAll.sh
roc_xterms_exit or hps3_exit
Home Directory: /usr/clas12/release/0.2/
Config files: ~/parms/trigger/HPS/TEST/MakeDaqCrash2.trg
Readout list: ~/coda/src/rol/rols/
Start Epics: hps_epics v2.0.0
Run Type: HPS3_NOER_NOTDC
Reboot Roc e.g. hps1: ssh hps1, hps/hpsRocStart.sh ???
Reboot the Crate: cd ~/slac_svt/svtdaq/daqv2/rceScripts/reboot_cobs.sh
tcpClient hps11 'tiSetRandomTrigger(1, prescale)'
tcpClient hps11 'tiDisableRandomTrigger()'
tcpClient hps11 'tiSetTriggerSource(0x5)'