To control the pulser on the TI master use the following commands:

To monitor trigger rates with strip charts open /home/hpsrun/trigratecharts.xml
HPSTRIGSC_5: gated pulser trigger rate  
HPSTRIGSC_0_PRE: gated single0 trigger rate 

 

Change pulser period to e.g. 100Hz:

tcpClient hps11 'sspPulserSetup(10,100.0,0.5,0xFFFFFFFF)'

Change block level to e.g. 40:

tcpClient hps11 'tiSetBlockLevel(40)'

Change prescale to e.g. 15:

tcpClient hps11 'tiSetInputPrescale(1,15)'

tcpClient hps11 tiStatus()

hps3_start

connect, configure, run type, prestart, Go

If mistake - cancel, reset

roc_xterms_start or hps/hpsRocStart.sh

hps/hpsRocRebootAll.sh

roc_xterms_exit or hps3_exit

Home Directory: /usr/clas12/release/0.2/

Config files: ~/parms/trigger/HPS/TEST/MakeDaqCrash2.trg

Readout list: ~/coda/src/rol/rols/

Start Epics: hps_epics v2.0.0

Run Type: HPS3_NOER_NOTDC

Reboot Roc e.g. hps1: ssh hps1, hps/hpsRocStart.sh ???

Reboot the Crate: cd ~/slac_svt/svtdaq/daqv2/rceScripts/reboot_cobs.sh

 

 tcpClient hps11 'tiSetRandomTrigger(1, prescale)'

 tcpClient hps11 'tiDisableRandomTrigger()'

tcpClient hps11 'tiSetTriggerSource(0x5)'

 