source: freehep-jaida/src/main/java/hep/aida/ref/plotter/PlotterRegion.java
Parameter | Description | Parameter Location | Affects | Values |
---|---|---|---|---|
xAxisLowerLimit | PlotterStyle | x axis | ||
lowerLimit | axis lower limit | PlotterStyle.xAxisStyle or yAxisStyle | axis | |
xAxisUpperLimit | PlotterStyle | x axis | ||
upperLimit | axis upper limit | PlotterStyle.xAxisStyle or yAxisStyle | axis | |
yAxisLowerLimit | PlotterStyle | y axis | ||
yAxisUpperLimit | PlotterStyle | y axis | ||
xAxisLabel | PlotterStyle | x axis | ||
yAxisLabel | PlotterStyle | y axis | ||
errorBarDecoration | PlotterStyle.errorBarStyle() | error bars | float | |
allowZeroSuppression | PlotterStyle.xAxisStyle() or Plotter.yAxisStyle() | x axis | boolean | |
showAsScatterPlot | PlotterStyle | Histogram2D | ||
showZeroHeightBins | PlotterStyle.dataStyle().fillStyle() | Histogram2D | ||
hist2DStyle | PlotterStyle | Histogram2D | box ellipse colorMap | |
colorMapScheme | PlotterStyle.dataStyle().fillStyle() | Histogram2D (when displayed as color map) | warm or 0 cool or 1 thermal or 2 rainbow or 3 grayscale or 4 userdefined or 5 | |
lineType | lineStyle() | solid or 0 dotted or 1 dashed or 2 dotdash or 3 | ||
markerShape | markerStyle() | dot or 0 box or 1 triangle or 2 star or 4 verticalLine or 5 horizontalLine or 6 cross or 7 cricle or 8 square or 9 | ||
markerShape (scatter) | markerStyle() | box or 1 triangle or 2 star or 4 verticalLine or 5 horizontalLine or 6 cross or 7 square or 9 | ||
globalIndex | style global index | PlotterStyle | ||
customOverlay | ||||
timeZone | time zone for date plots | PlotterStyle.dataStyle() | valid time zone string | |
profileErrors | display error on the mean or spread | IProfile | errorOnMean or 1 spread or 0 | |
normalization | PlotterStyle.dataStyle() | none entries maxbin area | ||
dataAreaBorderType | PlotterStyle.dataBoxStyle().borderStyle().borderType() | bevelIn or 0 bevelOut or 1 etched or 2 line or 3 shadow or 4 | ||
labelVertical | make X axis label vertical instead of horizontal | PlotterStyle.xAxisStyle() or Plotter.yAxisStyle() | boolean | |
log | log scaling (apparently parameter only has to start with "log") | PlotterStyle.xAxisStyle() or Plotter.yAxisStyle() | ||
yAxis | puts yAxis on right (default is left) | Y1 |
options format:
a=b;c=d
a="some string option value"
someBooleanOption <= means set option to true
Parameter | Description | Affects | Values |
---|---|---|---|
autoconvert | whether to autoconvert from cloud to histogram | Cloud | boolean |
range | range for function fit | fitting | examples (,-9) (-1.,0.) (2.,3.) (5,) |
noClone | whether function is cloned ???) | fitting | boolean |
annotation | see hep.aida.ref.histogram.AbstractBaseHistogram | BaseHistogram | |
margin | ??? | Cloud | |
type | basic type of histogram | Histogram1D | default efficiency |
useOutflowsInStatistics | ??? | Histogram1D Histogram2D Histogram3D | boolean |
OverlayIndex | int | ||
mode | overlay mode | replace overlay add stack | |
length | TupleColumn | int | |
maxlength | TupleColumn | int | |
calculatestatistics | TupleColumn | int | |
compress | file writing | zip yes true | |
binary | file writing | boolean | |
skip | ??? | file writing | boolean |
"By default the histogram's fill color, the contour of the histogram bar and the line between the points are taken from the line color. If the fill color is set and the histogram's bars are filled, the different color is used. Same for the line between the points."