SensorID | Cleaved at | Nitride? | Edge [um], UCSC | V break (V) CNM | V break (V) UCSC | Pinholes Sector A | Pinholes Sector B | Baking | V break (V) UCSC post-baking | Irrad. dose/ fluence | V break (V) UCSC post-irrad | Glued to Hybrid | Good/ Bad | Current Location | Notes__________ |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
W01-S2 | CNM | yes | 250 | 25 | 87 | 0 | 172 C, 24h | 85 | 1.03 Mrad | 175 | UCSC | ||||
W01-S4 | CNM | yes | 250 | 15 | 0 | 0 | 172 C, 24h | 70 | (100 Mrad) | UNM | |||||
W01-S6 | CNM | yes | 250 | 5 | 0 | 0 | 172 C, 24h | 5 | (100 Mrad) | UNM | |||||
W02-S1 | CNM | yes | 250 | 25 | 0 | 0 | 172 C, 24h | 90 | |||||||
W02-S2 | CNM | yes | 260 | 25 | 121, 177, 118, 176 | 0 | 172 C, 24h | 70 | 1.03 Mrad | 20 | UCSC | ||||
W02-S3 | CNM | yes | 244 | 20 | 0 | 0 | 172 C, 24h | 70 | 1.03 Mrad | 45 | UCSC | ||||
W02-S4 | CNM | yes | 250 | 20 | 0 | 0 | 168 C, 40 h | 80 | 1.03 Mrad | 110 | UCSC | ||||
W02-S6 | CNM | yes | 250 | 20 | 0 | 0 | 168 C, 40 h | 70 | 1.03 Mrad | 165 | UCSC | ||||
W03-S1 | CNM | yes | 244-252 | 25 | 0 | 0 | 168 C, 40 h | 85 | |||||||
W03-S2 | CNM | yes | 250 | 20 | 0 | 0 | 168 C, 40 h | 85 | |||||||
W03-S3 | CNM | yes | 250 | 30 | 0 | 0 | 168 C, 40 h | 85 | SLAC | Smudge from vacuum pen cleaned off at SLAC and UCSC | |||||
W03-S4 | CNM | yes | 178 | 180 | 0 | 0 | 168 C, 40 h | 180 | SLAC | Wiped with ethanol at SLAC. Very slim edge (no metal line). | |||||
W03-S5 | CNM | yes | 250 | 20 | 37, 100 | 0 | 172 C, 24h | 25 | (100 Mrad) | UNM | |||||
W03-S6 | CNM | yes | 250 | 15 | 0 | 0 | 172 C, 24h | 65 | (100 Mrad) | UNM | |||||
W05-S1 | CNM | yes | 250 | 30 | 0 | 0 | 172 C, 24h | 70 | |||||||
W05-S4 | CNM | yes | 250 | 30 | 0 | 0 | 172 C, 24h | 70 | (100 Mrad) | UNM | |||||
W05-S6 | CNM | yes | 250 | 25 | 0 | 0 | 172 C, 24h | 90 | |||||||
W06-S1 | CNM | yes | 250 | 30 | 0 | 0 | 172 C, 24h | 95 | |||||||
W06-S2 | CNM | yes | 250 | 25 | 0 | 0 | 168 C, 40 h | 110 | |||||||
W06-S3 | CNM | yes | 250 | 25 | 0 | 0 | 168 C, 40 h | 70 | 1.03 Mrad | 50 | UCSC | ||||
W06-S4 | CNM | yes | 250 | 25 | 0 | 0 | 168 C, 40 h | 105 | |||||||
W06-S6 | CNM | yes | 250 | 30 | 0 | 160, 170 | 168 C, 40 h | 100 | |||||||
W04-S1 | CNM | yes | 247 | 50 | 0 | 0 | (3.1e13 neq) | 55 | UCSC | ||||||
W04-S2 | CNM | yes | 250 (meas) | 25 | 0 | 0 | (3.1e13 neq) | 60 | UCSC | ||||||
W04-S3 | CNM | yes | 246 | 5 | 0 | 0 | (3.1e13 neq) | 80 | UCSC | ||||||
W04-S4 | CNM | yes | 248 | 5 | 171, 172, 173 | 0 | (3.1e13 neq) | 95 | UCSC | ||||||
W04-S5 | CNM | yes | 248 | 7 | 0 | 0 | (3.1e13 neq) | 60 | UCSC | ||||||
W04-S6 | CNM | yes | 250 | 20 | 0 | 0 | (3.1e13 neq) | 50 | UCSC | ||||||
W07-S1 | CNM | yes | 248; 316 on a corner | 15 | 0 | 0 | (3.1e13 neq) | 95 | UCSC | ||||||
W07-S2 | CNM | yes | 248 | 80 | 0 | 0 | (3.1e13 neq) | 90 | UCSC | ||||||
W07-S3 | CNM | yes | 249 | 5 | 0 | 176 | (3.1e13 neq) | 85 | UCSC | ||||||
W07-S4 | CNM | yes | 247 | 35 | 0 | 0 | (3.1e13 neq) | 150 | UCSC | ||||||
W07-S5 | CNM | yes | Broken | 55 | n.m. | n.m. | (3.1e13 neq) | 40 | UCSC | Unusable - broken in half | |||||
W07-S6 | CNM | yes | 247 | 15 | 32, 33, 34, 35, 36, 73, 74, 77, 79, 85 | 0 | (3.1e13 neq) | 65 | UCSC | ||||||
W08-S1 | CNM | yes | 252 | 60 | 170, 171 | 0 | (3.1e13 neq) | 115 | UCSC | ||||||
W08-S2 | CNM | yes | 149 (center), 138-237 (ends) | >200 | 65, 66 | 0 | (3.1e13 neq) | >195 | UCSC | Very slim edge (no metal line). | |||||
W08-S3 | CNM | yes | 251 | 65 | 175, 176 | 0 | (3.1e13 neq) | 75 | UCSC | ||||||
W08-S4 | CNM | yes | bad cleave | 1 | 0 | 0 | (3.1e13 neq) | 80 | UCSC | Not usable; cracked? | |||||
W08-S5 | CNM | yes | bad cleave | n.m. | n.m. | (3.1e13 neq) | 140 | UCSC | Not usable | ||||||
W08-S6 | CNM | yes | 420 (center), uneven | 55 | 0 | 0 | (3.1e13 neq) | 55 | UCSC | Not usable | |||||
W12-S1 | CNM | yes | 249 | 1 | 0 | 216, 234, 235 | (3.1e13 neq) | 70 | UCSC | ||||||
W12-S3 | CNM | yes | 251 | 40 | 0 | 0 | (3.1e13 neq) | 80 | UCSC | ||||||
W12-S4 | CNM | yes | 247 | 95 | 39, 48, 49, 64, 77, 78 | 0 | (3.1e13 neq) | 80 | UCSC | ||||||
W12-S5 | CNM | yes | (250) | 95 | 25 | 0 | 0 | 146C/23 h + 164 C/47 h | 75 | UCSC | |||||
W12-S6 | CNM | yes | 250 (meas) | 1 | 193, 194, 196 | 0 | (3.1e13 neq) | 105 | UCSC | 378 um wide piece sticks out on a short edge | |||||
W14-S1 | CNM | yes | (250) | 105 | 70 | 0 | 0 | 146C/23 h + 164 C/47 h | 115 | UCSC | |||||
W14-S2 | CNM | yes | (250) | 120 | 40 | 0 | 0 | 146C/23 h + 164 C/47 h | 110 | UCSC | |||||
W14-S4 | CNM | yes | 250 (meas) | 90 | 0 | 0 | (3.1e13 neq) | 105 | UCSC | ||||||
W14-S5 | CNM | yes | (250) | 110 | 70 | 0 | 0 | 146C/23 h + 164 C/47 h | 105 | UCSC | |||||
W14-S6 | CNM | yes | 248 | 35 | 211, 212, 214 | (3.1e13 neq) | 135 | UCSC | |||||||
W09-S1 | (NRL) | no | 105 | 45 | 0 | CNM IV was on wafer | |||||||||
W09-S3 | (NRL) | no | 110 | 0 | 0 | CNM IV was on wafer | |||||||||
W09-S6 | (NRL) | no | 75 | 0 | 47 | CNM IV was on wafer | |||||||||
W10-S1 | (NRL) | no | 50 | 0 | 0 | CNM IV was on wafer | |||||||||
W10-S2 | (NRL) | no | 27 | 0 | 0 | CNM IV was on wafer | |||||||||
W10-S3 | (NRL) | no | 80 | 0 | 0 | CNM IV was on wafer | |||||||||
W10-S4 | (NRL) | no | 75 | 0 | 0 | CNM IV was on wafer | |||||||||
W10-S5 | (NRL) | no | 95 | 0 | 0 | CNM IV was on wafer | |||||||||
W10-S6 | (NRL) | no | 85 | 0 | 0 | CNM IV was on wafer | |||||||||
W11-S2 | (NRL) | no | 110 | 68 | 30, 31 | CNM IV was on wafer | |||||||||
W11-S3 | (NRL) | no | 75 | 65, 66 | CNM IV was on wafer | ||||||||||
W11-S4 | (NRL) | no | 110? | 146 | CNM IV was on wafer | ||||||||||
W11-S5 | (NRL) | no | 85 | 0 | 0 | CNM IV was on wafer | |||||||||
W13-S1 | (NRL) | no | 95 | 0 | 0 | CNM IV was on wafer | |||||||||
W13-S2 | (NRL) | no | 97 | 0 | 0 | CNM IV was on wafer | |||||||||
W13-S3 | (NRL) | no | 80 | 0 | 0 | CNM IV was on wafer | |||||||||
W13-S4 | (NRL) | no | 90 | 0 | 0 | CNM IV was on wafer | |||||||||
W13-S5 | (NRL) | no | 90 | 0 | 0 | CNM IV was on wafer | |||||||||
W13-S6 | (NRL) | no | 85 | 0 | 0 | CNM IV was on wafer | |||||||||
W15-S2 | (NRL) | no | 85? | 204, 205 | 0 | CNM IV was on wafer | |||||||||
W15-S3 | (NRL) | no | 90 | 0 | 0 | CNM IV was on wafer | |||||||||
W15-S4 | (NRL) | no | 77 | 201, 202, 203 | CNM IV was on wafer | ||||||||||
W15-S5 | (NRL) | no | 45 | 0 | 0 | CNM IV was on wafer | |||||||||
W15-S6 | (NRL) | no | 97 | 0 | 0 | CNM IV was on wafer |