Sensor #

Glued to Hybrid

Received

V dep (V) CNM

Av. Edge (um), UCSC

V break (V) CNM

V break (V) UCSC

Pinholes Sector A from Half-Module Testing

Pinholes Sector B from Half-Module TestingNumber of Pinholes
W01-S4gimp01/13/2019  1201205, 22, 142, 157, 2553, 31, 34, 51, 83, 127, 134, 135, 146, 156, 176, 179, 213, 241, 24520
W07-S3L0M0202/27/20192336738013028, 65, 193, 19410, 37, 48, 57, 88, 112, 143, 165, 199, 200, 227, 234, 24617
W07-S5L0M1002/27/2019303274203351, 39, 61, 126, 146, 151, 154, 186, 194, 220

35, 70, 78, 93, 94, 103, 119, 120, 134, 135, 137, 155, 157, 166, 176, 181, 188, 206, 208, 240, 241, 243, 250

33
W09-S2L0M0702/27/201923360 (399)240~3008, 44, 159, 188, 19773, 171, 237, 2459
W09-S5L0M0102/27/201923342120120122, 160, 162, 225, 246, 24817, 37, 48, 57, 58, 59, 60, 106, 107, 122, 144, 161, 226, 231, 246, 247, 24922
W02-S4L0M0402/27/201923331150135Way too many to careWay too many to care~200
W03-S6L0M0802/27/201918328280190Way too many to careWay too many to care~200
W04-S3L0M0902/27/20192534935037016, 52, 97, 121, 172, 187, 198, 227, 23231, 49, 86, 123, 12514
W04-S6L0M1202/27/201918304 (340)4804203, 4, 5, 6, 10, 11, 12, 13, 14, 15, 86, 88, 113, 132, 190, 23381, 108, 146, 180, 226, 228, 25323
W07-S4L0M1102/27/2019N/A244N/A~2209, 14, 64, 67, 82, 84, 98, 118, 138, 153, 162, 199, 200, 208, 209, 2469, 11, 15, 17, 19, 52, 62, 63, 89, 95, 104, 107, 115, 144, 166, 18632
W10-S1L0M1903/25/201930298 (338)220-400~27018, 23, 49, 105, 159, 171, 203, 206, 209118, 20411
W10-S3L0M1503/25/201930395 (442)~22029075, 112, 133, 174, 207, 253204, 2318
W10-S4L0M0303/25/201930366250~200122, 143, 21024, 655
W10-S6L0M2003/25/201930274400~3405, 22, 27, 40, 50, 63, 85, 2381569
W11-S1L0M1603/25/201932352 (398)470330105, 110, 127204, 220, 1636
W11-S2L0M2203/25/201932337 (358)40042087, 101, 152, 225, 25549, 50, 2258
W11-S3L0M1703/25/201932318450340112, 167, 173, 174, 25330, 49, 165, 2049
W11-S4L0M2103/25/20193231513515024, 42, 122, 143, 216, 232, 233, 242, 251, 25465, 171, 179, 180, 181, 182, 183, 184, 210, 21520
W11-S5L0M1303/25/201932303 (335)28029048, 90, 129, 2401, 32, 36, 38, 49, 90, 143, 18412
W11-S6L0M1803/25/201932377 (425)32037018, 197, 242NONE!3

 

 

Sensors with reasonable number of pinholes:


Sensor #

Glued to Hybrid

Received

V dep (V) CNM

Av. Edge (um), UCSC

V break (V) CNM

V break (V) UCSC

Pinholes Sector A from Half-Module Testing

Pinholes Sector B from Half-Module TestingNumber of Pinholes
W09-S2L0M0702/27/201923360 (399)240~3008, 44, 159, 188, 19773, 171, 237, 2459
W10-S3L0M1503/25/201930395 (442)~22029075, 112, 133, 174, 207, 253204, 2318
W10-S4L0M0303/25/201930366250~200122, 143, 21024, 655
W11-S1L0M1603/25/201932352 (398)470330105, 110, 127204, 220, 1636
W11-S2L0M2203/25/201932337 (358)40042087, 101, 152, 225, 25549, 50, 2258
W11-S3L0M1703/25/201932318450340112, 167, 173, 174, 25330, 49, 165, 2049
W11-S4L0M2103/25/20193231513515024, 42, 122, 143, 216, 232, 233, 242, 251, 25465, 171, 179, 180, 181, 182, 183, 184, 210, 21520
W11-S6L0M1803/25/201932377 (425)32037018, 197, 242NONE!3

 

Sorting by slim edge width argues for L0M21, L0M17, L0M22, L0M16 in L0.

L0M21 has a low breakdown voltage so substitute L0M19.

L0M03, L0M15, L0M18, L0M07 go in slim L1.

Sensors after building L0 and slim L1:

Sensor #

Glued to Hybrid

Received

V dep (V) CNM

Av. Edge (um), UCSC

V break (V) CNM

V break (V) UCSC

Pinholes Sector A from Half-Module Testing

Pinholes Sector B from Half-Module TestingNumber of Pinholes
W01-S4gimp01/13/2019  1201205, 22, 142, 157, 2553, 31, 34, 51, 83, 127, 134, 135, 146, 156, 176, 179, 213, 241, 24520
W07-S3L0M0202/27/20192336738013028, 65, 193, 19410, 37, 48, 57, 88, 112, 143, 165, 199, 200, 227, 234, 24617
W07-S5L0M1002/27/2019303274203351, 39, 61, 126, 146, 151, 154, 186, 194, 220

35, 70, 78, 93, 94, 103, 119, 120, 134, 135, 137, 155, 157, 166, 176, 181, 188, 206, 208, 240, 241, 243, 250

33
W09-S5L0M0102/27/201923342120120122, 160, 162, 225, 246, 24817, 37, 48, 57, 58, 59, 60, 106, 107, 122, 144, 161, 226, 231, 246, 247, 24922
W02-S4L0M0402/27/201923331150135Way too many to careWay too many to care~200
W03-S6L0M0802/27/201918328280190Way too many to careWay too many to care~200
W04-S3L0M0902/27/20192534935037016, 52, 97, 121, 172, 187, 198, 227, 23231, 49, 86, 123, 12514
W04-S6L0M1202/27/201918304 (340)4804203, 4, 5, 6, 10, 11, 12, 13, 14, 15, 86, 88, 113, 132, 190, 23381, 108, 146, 180, 226, 228, 25323
W07-S4L0M1102/27/2019N/A244N/A~2209, 14, 64, 67, 82, 84, 98, 118, 138, 153, 162, 199, 200, 208, 209, 2469, 11, 15, 17, 19, 52, 62, 63, 89, 95, 104, 107, 115, 144, 166, 18632
W10-S6L0M2003/25/201930274400~3405, 22, 27, 40, 50, 63, 85, 2381569
W11-S4L0M2103/25/20193231513515024, 42, 122, 143, 216, 232, 233, 242, 251, 25465, 171, 179, 180, 181, 182, 183, 184, 210, 21520
W11-S5L0M1303/25/201932303 (335)28029048, 90, 129, 2401, 32, 36, 38, 49, 90, 143, 18412

 

 

  • No labels