Sensor # | Received | Tested | V dep (V) CNM | Av. Edge (um), UCSC | V break (V) CNM | V break (V) UCSC | Pinholes Sector A | Pinholes Sector B | Baking | Nitride on the back? | Glued to Hybrid | Goodness | Current Location | Notes |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
W01-S4 | 01/13/2019 | 120 | 120 | 93, 207, 227, 249, 44, 76, 96, 124, 138, 142, 170, 204 | 98 | No | gimp | gimp | SLAC | |||||
W07-S2 | 02/27/2019 | UCSC-baking2 | 30 | 397 | 60 | 30 | 143, 173, 16, 150, 198 | 1, 21, 71, 103, 217, 102 | 171 C for 27 h on 2019/03/11 | Yes | NG | UCSC (03/08/19) | GP2; got worse after baking | |
W07-S3 | 02/27/2019 | UCSC | 23 | 367 | 380 | 130 | 194 | 165, 199, 88, 200 | Yes | L0M02 | Used | module | GP2 | |
W07-S5 | 02/27/2019 | UCSC-baking2 | 30 | 327 | 420 | 335 | 117, 127, 128 | 43, 156, 164, 212 | 171 C for 27 h on 2019/03/11 | Yes | L0M10 | Good Candidate | SLAC (03/14/19) | GP2, improved a lot after baking |
W07-S6 | 02/27/2019 | UCSC-baking2 | 23 | 345 | 150 | 40 | 192, 194 | 13 | 171 C for 27 h on 2019/03/11 | Yes | NG | UCSC (03/08/19) | GP2; slimmed down on short side; got worse after slimming and baking | |
W09-S2 | 02/27/2019 | UCSC-baked2 | 23 | 360 (399) | 240 | ~300 | 159, 197, 8, 44, 188 | 73 | 171 C for 27 h on 2019/03/11 | Yes | L0M07 L1ta | Good Candidate | SLAC (03/14/19) | GP2, improved a lot after baking |
W09-S5 | 02/27/2019 | UCSC | 23 | 342 | 120 | 120 | 27, 86, 100, 116 | 100 | Yes | L0M01 | Used | module | GP2 | |
W02-S1 | 02/27/2019 | 20 | 416 (452) | 50 | 180 | 4 | 24 | 170 C for 23 h | Yes | No, edge too wide; nitride was scrapped on the back side --> to IV (COMPLETE) | UCSC (03/08/19) | GP1, Displaced in Gelpack | ||
W02-S4 | 02/27/2019 | UCSC Baked | 23 | 331 | 150 | 135 | 35, 221, 138 | 29, 77, 98 | 170 C for 23 h | Yes | L0M04 | Candidate | SLAC (03/08/19) | GP1, Displaced in Gelpack |
W03-S6 | 02/27/2019 | UCSC Baked | 18 | 328 | 280 | 190 | 44, 186, 200 | 149, 213, 36, 58 | 170 C for 23 h | Yes | L0M08 | Candidate | SLAC (03/08/19) | GP1, Displaced in Gelpack |
W04-S3 | 02/27/2019 | UCSC | 25 | 349 | 350 | 370 | 97, 187, 227, 52, 172 | 49, 123, 86 | Yes | L0M09 | Good candidate | SLAC (03/08/19) | GP1, In Gelpack with displaced chips | |
W04-S6 | 02/27/2019 | UCSC | 18 | 304 (340) | 480 | 420 | 51, 218 | 40, 48, 90 | Yes | L0M12 | Good candidate | SLAC (03/08/19) | GP1, In Gelpack with displaced chips | |
W07-S1 | 02/27/2019 | 23 | 290 (297) | >500 | 130 | 101, 207, 209, 247, 110, 192, 208 | 88 | 170 C for 23 h | Yes | 2nd-order candidate | SLAC (03/08/19) | GP1, In Gelpack with displaced chips | ||
W01-S6 | 01/15/2019 | UCSC | UCSC | ~240 | ~120-300 | 37, 41, 103, 171, 191, 195, 199, 203, 239, 24 | 11, 73, 12, 16, 212 | No | 3rd-order candidate | SLAC (03/08/19) | the non-slim long edge is cut to ~550 um. No nitride. IV is irregular, but under 10 uA at 350 V. | |||
W04-S5 | 01/15/2019 | UCSC-baked2 | UCSC | 450 | 445 | 17, 39, 73, 181, 217, 253, 24, 30, 40, 68, 134, 150, 164, 200, 220 | 101, 121, 78, 88, 98, 122 | 171 C for 27 h on 2019/03/11 | No | 2nd-order candidate (pinholes) | SLAC (03/14/19) | 1st delivery of mechanical pieces; improved by baking | ||
W07-S4 | 02/27/2019 | N/A | 244 | N/A | ~220 | 67, 199, 64, 82, 116, 118, 162, 200, 208 | 17, 63, 95, 52, 62, 104, 144, 186 | 170 C for 63.5 h on 2019/04/01 | No | L0M11 | good candidate | UCSC (03/28/19) | Was mech. piece; cleaved by NRL | |
W08-S1 | 02/27/2019 | N/A | 202 | N/A | ~340 | 171, 197, 213, 241, 249, 251, 253, 12, 16, 24, 28, 42, 82, 94, 120, 142, 152, 156, 182, 198, 208, 250 | 37, 51, 139, 187, 84, 88, 104, 116, 160 | 170 C for 63.5 h on 2019/04/01 | No | 2nd-order candidate (pinholes) | UCSC (03/28/19) | Was mech. piece; cleaved by NRL | ||
W10-S1 | 03/25/2019 | 30 | 298 (338) | 220-400 | ~270 | 49, 105, 159, 171, 199, 203, 207, 209, 239, 18, 206 | 118, 204 | 170C for 20.5 hr on 2019-03-28 | No | L0M19 L0ta | good candidate | UCSC (03/28/19) | ||
W10-S2 | 03/25/2019 | 30 | 311 (501) | 390 | 370 | 3, 8, 146, 152, 230 | 77, 196 | 170C for 20.5 hr on 2019-03-28 | No | 3rd-order: wide edge on the back side, pinholes close to the edge | UCSC (03/28/19) | |||
W10-S3 | 03/25/2019 | 30 | 395 (442) | ~220 | 290 | 75, 133, 207, 253, 112, 174 | 204 | 170C for 20.5 hr on 2019-03-28 | No | L0M15 L1bs | candidate for L1? | UCSC (03/28/19) | ||
W10-S4 | 03/25/2019 | 30 | 366 | 250 | ~200 | 143, 122, 210 | 65, 24 | 170C for 20.5 hr on 2019-03-28 | No | L0M03 L1ba | good candidate | UCSC (03/28/19) | ||
W10-S5 | 03/25/2019 | 30 | 338 | 50 | 50 | 229, 14, 100, 224 | 91, 129, 137, 197, 86, 132, 198 | 170C for 20.5 hr on 2019-03-28 | No | NG | UCSC (03/28/19) | |||
W10-S6 | 03/25/2019 | 30 | 274 | 400 | ~340 | 154 | 17, 39, 6, 84, 228 | 170C for 20.5 hr on 2019-03-28 | No | L0M20 | good candidate | UCSC (03/28/19) | ||
W11-S1 | 03/25/2019 | 32 | 352 (398) | 470 | 330 | 105, 127, 163 | 204, 220 | No | L0M16 L0bs | good candidate for L1 | UCSC (03/28/19) | |||
W11-S2 | 03/25/2019 | 32 | 337 (358) | 400 | 420 | 87, 101, 225, 152 | 49, 225, 50 | No | L0M22 L0ts | good candidate | UCSC (03/28/19) | |||
W11-S3 | 03/25/2019 | 32 | 318 | 450 | 340 | 167, 173, 253, 112, 174 | 49, 165, 30, 204 | No | L0M17 L0ba | good candidate | UCSC (03/28/19) | |||
W11-S4 | 03/25/2019 | 32 | 315 | 135 | 150 | 143, 233, 251, 42, 122, 216, 232, 242, 254 | 65, 171, 179, 181, 183, 215, 180, 182, 184, 210 | No | L0M21 | 2nd-order candidate | UCSC (03/28/19) | |||
W11-S5 | 03/25/2019 | 32 | 303 (335) | 280 | 290 | 43, 83, 14, 132, 214 | 91, 86, 132, 226 | No | L0M13 | good candidate | UCSC (03/28/19) | Pinholes don't match | ||
W11-S6 | 03/25/2019 | 32 | 377 (425) | 320 | 370 | None | 199, 28, 224 | No | L0M18 L1ts | good candidate for L1? | UCSC (03/28/19) | |||
W01-S2 | 03/25/2019 | 23 | 348 (385) | ~180 (bc) | ~160 | 37, 79, 223, 28, 146 | 229,14 | 170 C for 63.5 h on 2019/04/01 | No | risky for signal level | UCSC (03/28/19) | Ccouple very low | ||
W01-S5 | 03/25/2019 | 23 | 246 | ~250 (bc) | ~180 | 107, 117, 161, 179, 183, 215, 251, 255 | None | 170 C for 63.5 h on 2019/04/01 | No | risky for signal level | UCSC (03/28/19) | Ccouple very low | ||
W02-S3 | 03/25/2019 | 26 | 334 | >500 (bc) | ~360 | 227, 14 | 48, 128 | 170 C for 63.5 h on 2019/04/01 | No | candidate | UCSC (03/28/19) | Ccouple low, but may be ok | ||
W02-S5 | 03/25/2019 | 26 | 292 | >500 (bc) | ~380 | 183, 223, 255, 138 | 175 | 170 C for 63.5 h on 2019/04/01 | No | candidate | UCSC (03/28/19) | Ccouple low, but may be ok | ||
W09-S1 | 03/25/2019 | 30 | 328 (369) | 50 | 60 | 31, 127, 159, 130, 152, 248 | 1, 109, 221, 118 | 170 C for 63.5 h on 2019/04/01 | No | NG | UCSC (03/28/19) | bad piece, will bake | ||
W09-S3 | 03/25/2019 | 30 | 352 | 110 | 125 | 136, 142 | 10, 68, 128 | 170 C for 63.5 h on 2019/04/01 | No | 3rd-order candidate | UCSC (03/28/19) | bad piece, will bake | ||