This page describes the data format as received by software from the Packetizer/RSSI/UDP core.
The frame received by software will contain a series of trigger frames as output from the Firmware Event Builder. The number of event builder frames will be determined by the configured block size (N).
These frames will be formed into a larger frame using the SLAC Stream Batcher protocol.
First a single Trigger Block Header will be included
- Batcher Header receive per Trigger Block (64-bits) - Batcher superframe header
- Trigger Block Header Word 0 (32-bits)
- 31:16 = 0x0000
- 15:08 = Sequence # (running, spans each run)
- 07:04 = 0x2 (64-bits)
- 03:00 = 0x1 (version 1)
- Trigger Block Header Word 1 (32-bits)
Next will be N data sections, one for each trigger. Each section will contain the Event Builder Header, N MultiSamples and 64-bit tail.
- Event Builder Header 0 (32-bits)
- Event Builder Header 1 (32-bits)
- 31:08 = 0x000000
- 07:00 = RCE Address
- Event Builder Header 2/3 (64-bits)
- 63:00 = Timestamp
- A 64-bit running counter gets reset to 0 at the start of each run
- This number will be the same across all DPMs for a given trigger event
- MultiSample Data ( M * 4 * 32-bits) (M depends on data reduction)
- Event Builder Tail - (32-bits)
- 27: FIFO backup error (Should only see skip counts if this is 1)
- 26: ApvBufferAddressSyncError - APV frames didn't have the same addresses
- 23:12: SkipCount - Number of MultiSamples that got dumped due to FIFO backup
- 11:00: Number of MultiSamples (M)
- Per Trigger Tail Word 0 (32-bits) - Batcher sub-frame tail 0
- 31:00: Number of valid bytes in data section, excluding tail (2 * 4 + M * 16)
- Per Trigger Tail Word 1 (32-bits) - Batcher sub-frame tail 1
- 31:24: 0x7 (Number of valid bytes last 64-bit word) (can be ignored)
- 23:17: 0x00 (Unused TUSER_LAST)
- 16: Error Flag
- 15:08: 0x00 (Unused TUSER_FIRST)
- 07:00: 0x00 (Unused TDEST Field)