Open Pull Requests:
- ISS:227 - Tuple Maker. - Action: More Discussion Needed.
- This needs documentation.
- This needs to be further cleaned up.
- Miriam's refactoring is nice, and cleans things up.
- Do we want to continue supporting this? - Probably yes.
- Tuple maker needs to use utils and not
- ISS:243 - Matrix is Singular Error - Action: Merge
- Causes small changes to the output.
- Prevents the code to give an exception, better than exception catching.
- ISS:272 - Fix Track State at ECAL Action: Merge
- ISS:280 - Cleanup GBLOutput for alignment. Action: Merge
- Make sure the GBLOuput reflects the changes in the tracking.
- Done in coordination with Allesandra.
- Iss:241 - Extrapolation to tilted plane using field map Action: Merge
- Allow the track to be extrapolated properly to a tilted plane.
- Add Runge-Kutta4 integrator to do this job.
- Norman will sit with Miriam and work out this merge.
Progress / Prospects:
Sebouh:
- Early events do not have Mya info.
- Created a list of runs that are "Golden": Cut on # hits > 200 in SVT, add 10 seconds before and 5 seconds after events that are "bad" due to bad SVT bias - see plots in presentation.
- Issues:
- Some files could not be copied to cache. See run 5274. Missing files.
- Some runs have high hit-count tail (see run 5386). Why?
- Omar suggests to plot Z0, to verify the position of the SVT.
- Other suggestions are to check the beam current and the beam halo.
- Probably fine. HW + Tracking people should review, then with Jeremy add new data to conditions database and process files.
- Prospects:
- Add crystal ball functions.
Norman:
- Documentation. Plots for NIM paper.
- Tracking re-factoring.
Jeremy:
Matt Solt:
Miriam - Prospects:
- Converting the alignment software, to use the output from hps-java GBL rather than the separate python GBL.
- Needs coordination with Allesandra and
- Incorporating Robert's kalman fitter into hps-java.
- Match up coordinate systems.
- Don't duplicate objects.
- Code needs re-factoring.