Search/Navigation:
Related:
SLAC/EPP/HPS Public
Jefferson Lab/Hall B/HPS Run Wiki
S30XL-LESA/LDMX
# | Stereo (FEB CH ID) | Axial (FEB CH ID) | Assembled | Surveyed | Goodness of HMs (stereo/axial); notes | Mounted | Assignment |
---|---|---|---|---|---|---|---|
0 (proto) | 14 | 20 | 10/8/14 (SU) | 10/8/14 (SU) | |||
0 | 24 | 9 | 10/21/14 (SU) | 10/28/14 (SU) | bad channels in 2 APVs furthest from beam | ||
1 | 26 (1) | 28 (0) | 10/13/14 (SU) | 10/28/14 (SU) | perfect | 11/6/14 (TKN) | B2 |
2 | 23 (3) | 25 (2) | 10/13/14 (SU) | 10/29/14 (SU) | perfect | 11/6/14 (TKN) | B3 |
3 | 5 (1) | 8 (0) | 10/13/14 (SU) | 10/29/14 (SU) | perfect | 11/6/14 (TKN) | T2 |
4 | 16 (3) | 1 (2) | 10/16/14 (SU) | 10/29/14 (SU) | perfect | 11/6/14 (TKN) | T3 |
5 | 2 (2) | 13 (3) | 10/16/14 (SU) | 10/29/14 (SU) | bad channels in APV furthest from beam | 11/6/14 (TKN) | B1 |
6 | 22 (3) | 29 (2) | 10/16/14 (SU) | 10/29/14 (SU) | perfect/bad channel in APV furthest from beam | 11/6/14 (TKN) | T1 |
7 | 14 | 21 | 10/21/14 (SU) | 11/3/14 (SU) | bad channels in 2 APVs furthest from beam; bad hinge fit, drilled out and sanded to fit | ||
8 | 7 | 3 | 10/13/14 (SU) | 11/3/14 (SU) | bad channels in APV furthest from beam | ||
9 | 15 | 19 | 10/16/14 (SU) | 11/3/14 (SU) | weird noise shape/bad channel (in APV furthest from beam) in warm runs |
"Golden" half-modules:
Sketchy:
Not QA'ed:
Avoid:
Stereo half-modules:
Axial half-modules:
Stereo for spare:
Axial for spare:
# | Stereo | Axial | Assembled | Surveyed | Mounted | Goodness of HMs (stereo/axial); notes | Mounted | Assignment |
---|---|---|---|---|---|---|---|---|
0 (proto) | 0, hole on block | 1, hole on lever | ||||||
0 | 4, hole on block | 19, hole on lever | 10/31/14 (SU) | 11/3/14 (SU) | bad channels in middle APVs | |||
1 | 5, hole on block | 6, hole on lever | 10/22/14 (SU) | 10/28/14 (SU) | perfect | 11/7/14 (SU) | B4 | |
2 | 7, hole on block | 8, hole on lever | 10/22/14 (SU) | 10/28/14 (SU) | perfect | 11/7/14 (SU) | B5 | |
3 | 9, hole on block | 12, hole on lever | 10/22/14 (SU) | 10/29/14 (SU) | perfect | 11/7/14 (SU) | B6 | |
4 | 2, hole on block | 3, hole on lever | 10/27/14 (SU) | 10/29/14 (SU) | perfect | 11/7/14 (SU) | T4 | |
5 | 10, hole on block | 11, hole on lever | 10/27/14 (SU) | 10/29/14 (SU) | perfect | 11/7/14 (SU) | T5 | |
6 | 17, hole on block | 18, hole on lever | 10/27/14 (SU) | 10/29/14 (SU) | perfect | 11/7/14 (SU) | T6 | |
7 | 15, hole on lever | 14, hole on lever | 10/27/14 (SU) | 11/3/14 (SU) | bad channels in APV furthest from beam/perfect | |||
8 | 1, hole on block | 13, hole on lever | 10/31/14 (SU) | 11/3/14 (SU) | bad channels on both edges/bad channels in 2 APVs furthest from beam | |||
9 |
"Golden" half-modules:
Stereo:
Axial:
Crappy: 0 (gimp), 16 (chipped APV, damaged connector), anything not golden (1 or 2 bad channels)