run range: 3183-3461 (spreadsheet here)
/home/hps/hps-group/hps_soft/hps-java/hps-distribution-3.1-SNAPSHOT-20141225-bin.jar (untagged)
DST: /mss/hallb/hps/engrun/pass0/dst/
data quality summary*: DQM-Averages-Pass0.dat, DQM-Averages-Pass0.root
ECal conditions tag: "pass0" (gains and pedestals only)
Collection Name | Collection Type | Description |
---|---|---|
TriggerBank | GenericObject | Trigger and SSP info (I think) |
EcalReadoutHits | RawCalorimeterHit | raw cellId/amplitude/timestamp of ECal hits |
FADCGenericHits | GenericObject | ??? |
EcalCalHits | CalorimeterHit | gain/pedestal corrected ECal hits |
EcalClusters | Cluster | clusters from simple clusterer (test run) |
EcalClustersIC | Cluster | clusters from IC clusterer |
RejectedHits | CalorimeterHit | hits that didn't get included in IC cluster |
EcalClustersGTP | CalorimeterHit | clusters from GTPOnlineClusterer |
*conversion between DQM summary .dat and .root files done with this script (pyROOT)
run range: 3183-3461 (spreadsheet here)
DST: /mss/hallb/hps/engrun/pass1/dst/
data quality root files: /home/hps/hps-work/data/data_quality/pass1/dqm
ECal conditions tag: "pass1" (gains and pedestals only)
ECal changes relative to Pass0:
gains from improved cosmic analysis
new pedestals
running for FADC mode-7 data
current-dependence in database for modes 1 & 3
time cuts on hit-seed coincidence in clustering
time-walk correction (for FADC mode 3)
top half of calorimeter shifted up by 3mm to reflect survey
Collection Name | Collection Type | Description |
---|---|---|
TriggerBank | LCGenericObject | TI and SSP info |
EcalReadoutHits | RawCalorimeterHit | raw cellId/amplitude/timestamp of ECal hits |
EcalCalHits | CalorimeterHit | gain/pedestal corrected ECal hits |
FADCGenericHits | LCGenericObject | ??? |
EcalReadoutExtraData | LCGenericObject | Extra data from ECal Mode-7 |
EcalExtraDataRelations | LCRelation | Link between EcalReadoutHits and ExtraData |
EcalClusters | Cluster | Recon Clusterer |
EcalClustersGTP | Cluster | GTP Clusterer |