System Tests Report Summary
The changes in the system tests for comparison of GR v17r35p3 and v17r35p2 (both using the rhel4_gcc34opt builds) reflect a fix to the CAL Overlay. Changes only appear in Overlay tests. The top level summary is that the CAL digi counts are generally reduced (CALTOWER, CALLAYER, CALCOLUMN) and values are shifted lower (CALADC plots, CALEAVE, FilterEnergy, FilterEnergyDiff).
Changes
*
System Test Plots
These are from the AllGammaOverlay test.
Although more events now have CAL hits (p3:38300 vs p2:38250, 40000 events were simulated), there are overall less total hits in the CAL.
CAL Multiplicity |
CAL digis by column |
---|---|
CAL digis by tower |
CAL digis by layer |
CAL ADC |
CAL digi energy average |
---|---|
CAL ADC range 2 (both faces) |
CAL ADC range 3 |
|
|
OBF filter energy |
Filter Energy - CalEnergyRaw |
After looking through the CAL Overlay problem description, I realized I should have pulled the integrating hits plot. The fix handles assigning overlay energy deposits to the proper volume element for being included in the energy calculation. I expect an increase in the ends and so it is weird that one end is increasing and the other decreasing relative to the previous version.
CAL Integrating Segments |
---|