System Tests Report Summary
A couple plots are flagged for the BackGndMixDC2 test in the comparison of v17r17 LPM enabled and v17r16 LPM enabled.
(LPM enabled means the system test JO included an extra line, G4Generator.physics_choice="QGSP_BERT_LPM";)
Although G4HadronSim was touched, it is not clear this should have changed anything? However, it is also not clear that if this introduced an issue with finding the hadronic interaction tables, that the difference should be so minor? Depending on the possible energy dependence, the background mix test may not be probing the change effectively.
There is also a system test run for v17r17 using the standard options, but this showed no differences.
Changes
- G4HadronSim - switch to using path to find interaction tables
- HepRepSvc - color tweak, new init param to help with big MC events
- TkrUtil - logging
- EventIntegrity - addresses JIRA GRINF-51, print event id of errors
BackGndMixDC2 Bit Comparison
For the same primary particles generated, we see a few less trigger bits in v17r17, but the changes are very minimal.
The generated particle tables are identical.
The trigger bit frequencies changed very slightly. The new version is in the top box, v17r16 is shown below. Trigger bit frequencies that changed typically decreased by a couple events.
BackGndMixDC2 v17r17 LPM enabled
TriggerAlg INFO Totals triggered/ processed: 40000/40000 bit frequency: all events value count CNO CALHI CALLO TKR ROI ------ ----- ----- ----- ----- ----- 0 35641 0 0 0 0 0 2 661 0 0 0 661 0 3 2621 0 0 0 2621 2621 4 220 0 0 220 0 0 6 68 0 0 68 68 0 7 418 0 0 418 418 418 12 4 0 4 4 0 0 14 6 0 6 6 6 0 15 41 0 41 41 41 41 16 154 154 0 0 0 0 18 7 7 0 0 7 0 19 104 104 0 0 104 104 20 8 8 0 8 0 0 22 6 6 0 6 6 0 23 31 31 0 31 31 31 28 2 2 2 2 0 0 31 8 8 8 8 8 8 ------ ----- ----- ----- ----- ----- tot: 40000 320 61 812 3971 3223
BackGndMixDC2 v17r16 LPM enabled
TriggerAlg INFO Totals triggered/ processed: 40000/40000 bit frequency: all events value count CNO CALHI CALLO TKR ROI ------ ----- ----- ----- ----- ----- 0 35634 0 0 0 0 0 2 661 0 0 0 661 0 3 2624 0 0 0 2624 2624 4 221 0 0 221 0 0 6 72 0 0 72 72 0 7 415 0 0 415 415 415 12 6 0 6 6 0 0 14 3 0 3 3 3 0 15 41 0 41 41 41 41 16 157 157 0 0 0 0 18 7 7 0 0 7 0 19 107 107 0 0 107 107 20 9 9 0 9 0 0 22 6 6 0 6 6 0 23 28 28 0 28 28 28 28 2 2 2 2 0 0 31 7 7 7 7 7 7 ------ ----- ----- ----- ----- ----- tot: 40000 323 59 810 3971 3222
BackGndMixDC2 GR v17r16 LPM enabled has a lot of complaints about the gamma levels file.
G4NuclearLevelManager: nuclide (53,129) does not have a gamma levels file FluxSvc INFO [2009-04-12 23:39:36] 1% complete: event 400, time= 0.00316508686298= launch+ 0.00316508686298 G4NuclearLevelManager: nuclide (12,25) does not have a gamma levels file G4NuclearLevelManager: nuclide (5,11) does not have a gamma levels file G4NuclearLevelManager: nuclide (28,60) does not have a gamma levels file