GLAST Standard Analysis Environment (SAE) Evaluation Questionnaire
Checkup 3
Sept 6, 2005 - Sept 27, 2005

Reviewer: Masaharu Hirayama
Software Component: gtselect
Summary of Tests Performed:
Data subselection with a time range and with a energy range.

Observation about tool:

See item 10 below.

User Interface

1. What, if anything, about the choice and meaning of parameters
could be improved? Are there new parameters which need to be
added? Are the current parameters sensible?

Some parameter names don't conform parameter interface standard by James.
http://lheawww.gsfc.nasa.gov/~peachey/glast/STParameterStandards.html

  • infile should be renamed to evfile.
  • evtable missing.

2. Are there any prompts you would suggest rewording?

"FT1" should not appear in prompts for infile and outfile.
Use the standards prompts proposed by James.
http://lheawww.gsfc.nasa.gov/~peachey/glast/STParameterStandards.html

3. Are there any hidden parameters which you think should be
prompted for or vice versa?

No.

4. Would you like the prompts to appear in a different order?

No.

5. Would you suggest changes to the default values of any
parameters? Changes to min, max fields?

No.

Tool Behavior

6. In what way, if any, did the tool perform unexpectedly?

None.

7. Were there any aspects of the tool's output which seem
scientifically suspicious to you? (e.g. fluxes too large,
number of events selected too small, etc.)

No.

8. Was there information (i.e. output) the tool did not provide
which you think it should?

No.

9. Was there information (i.e. output) the tool provided which
you think it should not?

No.

Future Development

10. List new features you would like to see implemented, in
descending order of importance. Please flag any which you
think are critical for DC2.

1) Cut by multiple time intervals, specified by a GTI extension or a
column-wise ASCII file.
2) Cut by user-defined Boolean/mathematical expression.
3) Cut by the FT2 parameter(s).
4) Allow a user to say "don't make a cut on that parameter," or change
a user interface so that the tool doesn't ask all the cut criteria.
5) Display a photon screening summary after screening,
so that a user can see how many photons are lost at each cut.
6) Command line editing and filename completion for user inputs
probably by introducing readline.
7) Warn a user if it removes all the photons in FT1.

11. Are there any aspects of this tool you would change in order
for it to work more smoothly with other parts of the SAE?

No.

General Notes

Please include here any comments about this tool which do not
fit into one of the categories above.

None.

  • No labels