This page lists the locations of various web servers managed by SCA, not including Fermi web servers which are listed separately.
Physical Host | HA | Virtual Host | OS | Cores | GB | Server | Comments |
---|---|---|---|---|---|---|---|
exolnx01-vmm | Yes | exolnx-v01 | RHEL 6 | 4 | 16 | EXO web server | |
exolnx01-vmm | Yes | exolnx-v02 | RHEL 6 | 4 | 16 | xrootd proxy server | |
exolnx01-vmm | Yes | exolnx-v03 | RHEL 6 | 4 | 16 | EXO event display server | |
exolnx01-vmm | Yes | exolnx-v04 | RHEL 6 | 4 | 16 | ||
exolnx01-vmm | Yes | Total | RHEL 6 | 16/16 | 64/64 | ||
scalnx01 | No | RHEL 6 | 16 | 16 | lsst-ftp.slac.stanford.edu | SRS Pipeline server vsftpd server for LSST vendor data | |
scalnx02-vmm | Yes | scalnx-v01 | RHEL 6 | 4 | 16 | SRS web server SRS datacat crawler cvs.freehep.org | |
scalnx02-vmm | Yes | scalnx-v02 | RHEL 6 | 4 | 16 | Runs Jenkins build agent srs-build02 | |
scalnx02-vmm | Yes | scalnx-v03 | RHEL 6 | 4 | 16 | svn.freehep.org, svn.slac.stanford.edu nexus.slac.stanford.edu | Subversion/job control daemons (allows all users to login) Nexus is started by hand from /gpfs/slac/staas/fs1/g/g.srs/nexus/monitor |
scalnx02-vmm | yes | lsst-teststand-proxy | RHEL 6 | 2 | 8 | Shutdown on 11/5/21. Deleting on 11/18/21. | |
scalnx02-vmm | yes | sca-virt-manager | RHEL 6 | 2 | 8 | ||
scalnx02-vmm | yes | Total | RHEL 6 | 16/12 | 64/48 | ||
scalnx03-vmm | scalnx-v04 | 4 | 14 | SiD web server (Shut down, not really used?). EXO/SRS dev tomcat server. Lost with scalnx03-vmm failure | |||
scalnx03-vmm | scalnx-v05 | 4 | 14 | LSST Camera web server (firefly) Lost with scalnx03-vmm failure | |||
scalnx03-vmm | scalnx-v06 | 4 | 14 | IEPM PingER Linked Open Data (Les Cottrell) Lost with scalnx03-vmm failure | |||
scalnx03-vmm | Total | 12/12 | 52/48 | FAILED | |||
sca-oracle01 | Yes | SRS pipeline/datacat oracle server | |||||
sca-oracle02 | No | Fermi DEV database | |||||
scalnx10-vmm | Yes | lsstlnx-v01 | RHEL 6 | 4 | 8 | http://lsst-camera.slac.stanford.edu/fftools | LSST Camera web server |
scalnx10-vmm | Yes | lsst-ftp | 1 | 1 | defunct due to bizarre external connection problems. Deleted on 11/5/21 | ||
scalnx10-vmm | Yes | lsst-testbed01 | 2 | 8 | Shutdown on 11/5/21. Deleting on 11/18/21 | ||
scalnx10-vmm | Yes | lsst-testbed02 | 2 | 8 | Shutdown on 11/5/21. Deleting on 11/18/21 | ||
scalnx10-vmm | Yes | lsstlnx-v02 | RHEL 6 | 1 | 4 | http://lsst-camera-dev.slacv.stanford.edu | |
scalnx10-vmm | Yes | Total | 10/16 | 29/128 | |||
scalnx11-vmm | Yes | lssttest1 | 1 | 1 | ? | Shutdown on 11/5/21. Deleting on 11/18/21 | |
scalnx11-vmm | Yes | cdmslnx-grid01 | 4 | 8 | Never used? | ||
scalnx11-vmm | Yes | lsst-dtn-test | 1 | 4 | ? | ||
scalnx11-vmm | Yes | cdmslnx-v01 | RHEL 6 | 1 | 4 | cdms (DAQ) tomcat server | |
scalnx11-vmm | Yes | Total | 7/16 | 17/128 | |||
scalnx12-vmm | Yes | sca-nginx01 | RHEL 6 | 6 | 12 | Many | See SCA NGINX Configuration |
scalnx12-vmm | Yes | sca-nginx03 | 1 | 2 | Primarily EXO Logbook (via nginx) | ||
scalnx12-vmm | Yes | Total | 7/16 | 14/128 | |||
scalnx13-vmm | Yes | sca-nginx02 | RHEL 6 | 6 | 12 | See SCA NGINX Configuration | |
scalnx13-vmm | Yes | lssttest2 | 1 | 1 | Shutdown on 11/5/21. Deleting on 11/18/21 | ||
scalnx13-vmm | Yes | Total | 7/16 | 13/128 | |||
(VMWare- Fermi) | Varies | fpdlnx7-v01 | Centos 7 | 4 | 16 | ||
(VMWare- Fermi) | Varies | fpdlnx7-v02 | Centos 7 | 4 | 16 | ||
(VMWare- Fermi) | Varies | fpdlnx7-v03 | Centos 7 | 4 | 16 | ||
(VMWare- Fermi) | Varies | fermi-ci-test01 | Centos 7 | 8 | 32 | Jenkins Worker (with Docker support - can build GlastRelease) oauth2_proxy for DESC (portal.lsstdesc.org, portal.lsst-desc.org) - via Docker oauth2_proxy is integrated in with sca-resty below. | |
(VMWare- Fermi) | Varies (yes) | sca-resty01 | Centos 7 | 6 | 12 | Configured via https://github.com/slaclab/sca-resty (Replacement for sca-nginx01/sca-nginx02) | |
(VMWare- Fermi) | Varies (yes) | sca-resty02 | Centos 7 | 6 | 12 | Configured via https://github.com/slaclab/sca-resty Not really used/setup properly with keepalived and a virtual IP. Ideally setup to do that. |