Date
Attendees
Discussion items
- Machine recovery: still unclear what the USI result will be, which is the pace-limiting item for beam recovery
- Maybe recover CM01 late today?
- RP inspecting the cable tray at noon
- LBLM certification close-outs - scheduled for 13:30 today
- Undoing dark current beam limiting measures from two weeks ago
- Might recover CM01 early tomorrow (7 am)
- Will only recover CM01, CM07 until Tuesday
- Ryan has something prepared to check frequencies after emergency detuning efforts two weeks ago
- Give different-infrastructure-autosetup another try on Tuesday
- Will get an on-call shift schedule today or tomorrow
- Sebastian gone next Thursday through Monday - Ryan will be acting area physicist for Linac West during that time
- J-Lab:
- Very different cryo than our system
- Module cooled down, no leak at this time
- No idea when next test will be
- Could we ask Mike Drury to help us get our “user visit” status setup?
- Maybe will do CMTF testing? Sebastian thinks it is not as worthwhile for us to support tests at this facility
- Time codes for last Monday: use of Emergency Pay and Safety Leave for anyone who could not come onsite and could not work from home
- Bryce wants us to go to the diagnostics meeting during the 11 am Thursday timeslot on 2/29 for Nicole’s HOMBOM presentation
- Ryan has an idea for a new scheme for looking for strong field emitters - he will test after the CM07 decarad test