Many thanks to Wei Yang for creating and documenting use of the container. Note that Singularity rebranded itself to Apptainer. So you can use those names interchangeably at present.
Singularity image files:
- /gpfs/slac/fermi/fs2/software/containers/slac-fermi.img.ext3
- This is an old, tested image
- /gpfs/slac/fermi/fs2/software/containers/fermi-centos6.20230314.sif
- on s3df, these containers can be found in: /sdf/group/fermi/sw/containers/
- They are available on both the AFS side and SDF side. You can copy them to other locations
- Instructions for how to build the container are in: /gpfs/slac/fermi/fs2/software/containers/fermi-rhel6.build.txt
For S3DF:
- export myimage=/sdf/group/fermi/sw/containers//fermi-rhel6.sif. That is symlinked to the "prod" container in that directory.
- Go inside the container:
- singularity shell -B /sdf $myimage
- By default, the prompt is changed to “Apptainer> “. You are now in a shell and can do “ls”, “cd”, etc.
- If you run command “id”, you will see you are running as yourself.
- if you need to see SDF filesystems (Lustre), add -B /fs/ddn/sdf
- Run a command in the container:
- singularity exec -B /sdf $myimage ls -l
- singularity exec -B /sdf $myimage sh myscript.sh
- The above is usually used in batch jobs.
- to work on the scratch space in batch, add -B /lscratch
- if you need to see SDF filesystems (Lustre), add -B /fs/ddn/sdf
How to run Singularity container from rhel6-64, centos7 and sdf-login:
- export myimage=/gpfs/slac/fermi/fs2/software/containers/slac-fermi.img.ext3
- or use the new image file:
- export myimage=/gpfs/slac/fermi/fs2/software/containers/fermi-centos6.sif
- Go inside the container:
- singularity shell -B /afs:/afs -B /gpfs:/gpfs $myimage
- By default, the prompt is changed to “Apptainer> “. You are now in a shell and can do “ls”, “cd”, etc.
- If you run command “id”, you will see you are running as yourself.
- Run a command in the container:
- singularity exec -B /afs:/afs -B /gpfs:/gpfs $myimage ls -l /afs
- singularity exec -B /afs:/afs -B /gpfs:/gpfs $myimage sh /afs/slac/myscript.sh
- The above is usually used in batch jobs.
- “-B /afs:/afs” means bind mount (make /afs available inside the container, as path /afs)
- Bind mount may not work well when running singularity on rhel6-64 machines, especially when autofs path (e.g. /nfs) is involved
- By default, /tmp and your working directories are bind mounted.
- on centos7, you can also bind mount nfs similarly.
page for collecting questions/issues and answers
5 Comments
Tyrel Johnson
EverythingMany things I have are set up for cshell, but when I try to change shells within the container it asks for my password and then gives me an authentication error. I have tried multiple times making absolutely certain I'm giving it the correct password, any ideas?Robert Cameron
Following the example at: https://sdf.slac.stanford.edu/public/doc/#/interactive-compute
it seems the command syntax in step 2 above can be simplified to:
Tyrel Johnson
Recently (as of yesterday) when using the container, I get a warning (see below) about the apptainer not being complete. Everything seems to run, but I wonder if I need to update some command or point to a different file?
[tyrelj@cent7a ~]$ setenv myimage /gpfs/slac/fermi/fs2/software/containers/slac-fermi.img.ext3
[tyrelj@cent7a ~]$ singularity shell -B /nfs:/nfs -B /afs:/afs -B /gpfs:/gpfs $myimage
WARNING: /etc/singularity/ exists, migration to apptainer by system administrator is not complete
Tyrel Johnson
Using the old image I now get a FATAL error:
[tyrelj@cent7d ~]$ setenv myimage /gpfs/slac/fermi/fs2/software/containers/slac-fermi.img.ext3
[tyrelj@cent7d ~]$ singularity shell -B /nfs:/nfs -B /afs:/afs -B /gpfs:/gpfs $myimage
INFO: /etc/singularity/ exists; cleanup by system administrator is not complete (see https://apptainer.org/docs/admin/latest/singularity_migration.html)
FATAL: configuration disallows users from mounting extfs in setuid mode, try --userns
(note, this is on centos7 machines as I haven't set everything up on the new cluster yet)
I don't get the same message when using "export myimage=/gpfs/slac/fermi/fs2/software/containers/fermi-centos6.sif", so maybe the old image is no longer valid from the command line (bash scripts using it seem to have worked).
Tyrel Johnson
Using --userns doesn't work, apparently things aren't set up to allow that. I can't even remove all the -B statements (did as a test) without getting the exact same error. Using 'exec' instead of 'shell' still seems to work, so it seems that I'm going to have to change some interactive steps to scripts because the new image doesn't have everything I need, somehow.