Minutes
RM Backend
Windows
MySQL passwords are stored in the registry. Some time ago, Navid thought he had updated the registry for all the windows boxes under User. Two machines didn't have those registry values set, not sure if they were missed originally, or if they were over-written. Richard suggested that perhaps they were cleared after the monthly patches, but Navid believes the registry values would be saved and reloaded.
Problem with remote connection into glast-06 is due to too many idle connections. The admins, closed down the existing connections and now Navid should be able to log in again.
The Macs seem to have a problem with passing tokens for LSF. Neal had mentioned the posibility of a problem, but this is the first time Navid has seen it himself. Things had been working for over a month, but starting on Tuesday at 9 AM jobs were not getting LSF tokens. Navid has contacted Neal who will contact Andy to see if there have been any changes made. There were troubles with the LSF tokens previously - but that had been fixed.
Toby has tagged Navid's updates to astro. We won't be sure that it fixed everything, until we can build on the Macs again.
Richard was looking for a status report on the various platforms:
rhel3 and rhel4 32 and 64 bit work
rhel5 won't work until we handle the issue with f2c. Packages like optimizers are looking for f2c which is not available.
Macs are almost ready -- need working LSF and then hoping developers will keep the code working on the mac. Recently, Navid has provided bug fixes, only to find that the next tag of packages like Likelihood introduce new bugs on the Mac. Jim has made some updates to Likelihood, Navid is hoping that will take care of the most recent problems. We are starting to look into builds on Leopard. Note that mac01 is tiger, and mac02 is now a leopard machine. Navid notes that tiger and leopard use the same gcc4. In fact we could use tiger binaries on leopard. However, the tiger machine will be removed from service, and we need to make sure that we can build everything on leopard.
Windows - once past the issue with the registry, the SciTool builds should proceed just fine.
mathlibs may be different on rh9 and rhel4
check first event
automatic notification
James P and Jim Chiang
RM Front End
Agenda
- Release Manager Status
- Backend
- Windows failing to compile
- Automatically notify package owners of build failures -- done, some suggestions from Toby
- Mac - fixed!
- u35 now used by SCons -- how is that going
- General Status
rhel3, rhel4 32 and 64 bit, rhel5 32 bit, and mac
Where is each as far as the 3 stages of builds? - Other Issues?
- Backend
- rhel4 and rhel5
- Any Babar news?
- rh9 when does FSW plan to dump it?
Whenever we're ready - Installer/ RMviewer /Tag Collector - Navid
- user releases are good to go
- developer release status
- Version 0.5 current test release
- available for testing from ftp://ftp-glast.slac.stanford.edu/glast.u05/RMViewer/
- status of current RM binary installs?
- To Do List
- Installer for Developer Releases
- Contact Tony concerning web based installer
- Tag Collecting
- Front End - Karen
- Web Front End - Karen
- http://glast-ground.slac.stanford.edu/rm2/
current test version is: http://glast-tomcat03.slac.stanford.edu:8080/rm2/ - How to get checkout and compile output like RMViewer?
- Recent Updates
- Reformat time stamps
- http://glast-ground.slac.stanford.edu/rm2/
- Web Front End - Karen
- SCons
- 1.2.0 is now installed on SLAC AFS as is a more recent developer version with additional Windows support.
- GoGui
- Windows Support
- stag command line tagger now available
- available for download from u05/stag
- Pop in "EOH" End of Header into release.notes for those package that do not have it
- Migrate to new tagging convention
- ST Builds
- GR Builds
- GlastRelease-scons v15r49 build status
- Need to check out using GlastRelease-15-49-00
Gleam package creates test_Gleam app, no Gleam. I think we need to add a definition for the Gleam application into the Gleam SConscript file?
- Need to check out using GlastRelease-15-49-00
- GlastRelease-scons build status
- obf restructuring - Emmanuel,Navid,Joanne
- Migration of JO files to top-level
- FRED and fox library
- CHS
- Last tag built, but with errors
- Externals
- ROOT upgrade v5.20 ready to go
- Fred & Fox
- Need to build for 64 bit machines and on the Mac. Wouldn't hurt to contact Riccardo about that.
The Big To Do
- RM
- Automatic email notification of build failures
- Migrate to new tagging convention
- What is the status of providing the ability for RM to catch and apply tags for either old or new style?
- Start using u35 -- DONE
- Fix up Windows builds
- Automate Mac builds again once LSF is fixed
- Doxygen generation
- Generation of calibration and geometry files
- Installer/TagCollector/RMViewer
- Provide Developer Releases
- Contact Tony to start work on web based installer
- Tag Collector
- ST
- Fix up Windows issues and get more developer support
- GR
- Update 15-49-00 SConscript files for the head of GR
- Fix up OBF handling
- Migrate JO files to top-level directory
- CHS
- Test and work out remaining issues before Bryson departs
- Windows
- Externals for VS9.
ROOT - DONE
- Externals
- ROOT v5.20
- Fred & Fox
- Gaudi