In response to the FSW group freezing B3-0-0, the offline has created a new onboard filter external library called B3-0-0-gl1. Currently L1proc is using GlastRelease 17-35-24-lp22, with OBF B1-1-3. There is a new GR build 17-35-24-lp28, where the only modification is to pick up OBF B3-0-0-gl1. This required modification to the OnboardFilter package as well as updating GlastRelease-scons/containerSettings.
System tests were run lp28 using lp22 as the baseline. The results show there was no change in the tests:
http://glast-ground.slac.stanford.edu/SystemTests/?releaseVersionId=13301
This is to be expected and is good news.
The digitization was run using the evt file: /nfs/farm/g/glast/u28/stageTest/120225001-chunk/r0351769427/r0351769427-e00000000000010067958.evt using both lp22 and lp28, running on the same dole0030 machine. Here are the results - in particular look at the MIP and HIP filters:
GlastRelease 17-35-24-lp22
EventSelector INFO Processed 66429 event from a file containing 66429 events
EventLoopMgr INFO No more events in event selection
TriggerAlg INFO Totals triggered/ processed: 66429/66429
bit frequency: all events
value count CNO CALHI CALLO TKR ROI
--- — -- — --- —
0 723 0 0 0 0 0
2 46357 0 0 0 46357 0
3 2279 0 0 0 2279 2279
4 9 0 0 9 0 0
6 7565 0 0 7565 7565 0
7 1997 0 0 1997 1997 1997
12 65 0 65 65 0 0
14 1106 0 1106 1106 1106 0
15 4337 0 4337 4337 4337 4337
18 1 1 0 0 1 0
19 71 71 0 0 71 71
22 1 1 0 1 1 0
23 284 284 0 284 284 284
28 1 1 1 1 0 0
31 1633 1633 1633 1633 1633 1633
--- — -- — --- —
tot: 66429 1991 7142 16998 65631 10601
EbfWriter INFO Wrote 66429 Total Events
OnboardFilter.G... INFO – Gamma Filter Status Word bit frequency table –
GFC_V3_STATUS_M_GEM_THROTTLE = 10077
GFC_V3_STATUS_M_GEM_TKR = 66020
GFC_V3_STATUS_M_GEM_CALLO = 16734
GFC_V3_STATUS_M_GEM_CALHI = 7364
GFC_V3_STATUS_M_GEM_CNO = 1991
GFC_V3_STATUS_M_ACD_TOP = 10069
GFC_V3_STATUS_M_ACD_SIDE = 22182
GFC_V3_STATUS_M_ACD_SIDE_FILTER = 9894
GFC_V3_STATUS_M_TKR_EQ_1 = 15654
GFC_V3_STATUS_M_TKR_GE_2 = 21361
GFC_V3_STATUS_M_RSVD_10 = 0
GFC_V3_STATUS_M_TKR_LT_2_ELO = 4253
GFC_V3_STATUS_M_TKR_SKIRT = 8
GFC_V3_STATUS_M_TKR_EQ_0 = 24
GFC_V3_STATUS_M_TKR_ROW2 = 28
GFC_V3_STATUS_M_TKR_ROW01 = 49
GFC_V3_STATUS_M_TKR_TOP = 207
GFC_V3_STATUS_M_SIDE = 101
GFC_V3_STATUS_M_TOP = 170
GFC_V3_STATUS_M_ZBOTTOM = 45
GFC_V3_STATUS_M_ERR_CTB = 331
GFC_V3_STATUS_M_SPLASH_1 = 2113
GFC_V3_STATUS_M_E350_FILTER_TILE = 32
GFC_V3_STATUS_M_E0_TILE = 73
GFC_V3_STATUS_M_EL0_ETOT_HI = 3755
GFC_V3_STATUS_M_EL0_ETOT_LO = 9706
GFC_V3_STATUS_M_LO_ENERGY = 20328
GFC_V3_STATUS_M_HI_ENERGY = 3688
GFC_V3_STATUS_M_SPLASH_0 = 516
GFC_V3_STATUS_M_NOCALLO_FILTER_TILE = 2245
GFC_V3_STATUS_M_NON_PHYSICS = 171
GFC_V3_STATUS_M_VETOED = 4000
OnboardFilter.M... INFO – MIP Filter Status Word bit frequency table –
MFC_STATUS_M_STAGE_GEM = 66428
MFC_STATUS_M_STAGE_ACD = 0
MFC_STATUS_M_STAGE_DIR = 0
MFC_STATUS_M_STAGE_CAL = 0
MFC_STATUS_M_STAGE_XCAL = 0
MFC_STATUS_M_MULTI_PKT = 0
MFC_STATUS_M_ERR_CAL = 0
MFC_STATUS_M_ERR_CTB = 0
MFC_STATUS_M_ERR_DIR = 0
MFC_STATUS_M_RSVD_09 = 0
MFC_STATUS_M_RSVD_10 = 0
MFC_STATUS_M_RSVD_11 = 0
MFC_STATUS_M_RSVD_12 = 0
MFC_STATUS_M_RSVD_13 = 0
MFC_STATUS_M_RSVD_14 = 0
MFC_STATUS_M_RSVD_15 = 0
MFC_STATUS_M_RSVD_16 = 0
MFC_STATUS_M_RSVD_17 = 0
MFC_STATUS_M_RSVD_18 = 0
MFC_STATUS_M_RSVD_19 = 0
MFC_STATUS_M_RSVD_20 = 0
MFC_STATUS_M_RSVD_21 = 0
MFC_STATUS_M_RSVD_22 = 0
MFC_STATUS_M_RSVD_23 = 0
MFC_STATUS_M_RSVD_24 = 0
MFC_STATUS_M_RSVD_25 = 0
MFC_STATUS_M_NO_TKR_ADJ = 0
MFC_STATUS_M_LYR_COUNTS = 0
MFC_STATUS_M_NO_ACD_TKR = 63371
MFC_STATUS_M_GEM_NOTKR = 501
MFC_STATUS_M_GEM_CNO = 2556
MFC_STATUS_M_VETOED = 66428
OnboardFilter.H... INFO – HIP Filter Status Word bit frequency table –
HFC_STATUS_M_STAGE_GEM = 66429
HFC_STATUS_M_STAGE_DIR = 0
HFC_STATUS_M_STAGE_CAL = 0
HFC_STATUS_M_STAGE_CAL_ECHK = 0
HFC_STATUS_M_STAGE_CAL_LCHK = 0
HFC_STATUS_M_MULTI_PKT = 0
HFC_STATUS_M_ERR_CAL = 0
HFC_STATUS_M_ERR_CTB = 0
HFC_STATUS_M_ERR_DIR = 0
HFC_STATUS_M_RSVD_09 = 0
HFC_STATUS_M_RSVD_10 = 0
HFC_STATUS_M_RSVD_11 = 0
HFC_STATUS_M_RSVD_12 = 0
HFC_STATUS_M_RSVD_13 = 0
HFC_STATUS_M_RSVD_14 = 0
HFC_STATUS_M_RSVD_15 = 0
HFC_STATUS_M_RSVD_16 = 0
HFC_STATUS_M_RSVD_17 = 0
HFC_STATUS_M_RSVD_18 = 0
HFC_STATUS_M_RSVD_19 = 0
HFC_STATUS_M_RSVD_20 = 0
HFC_STATUS_M_RSVD_21 = 0
HFC_STATUS_M_RSVD_22 = 0
HFC_STATUS_M_RSVD_23 = 0
HFC_STATUS_M_RSVD_24 = 0
HFC_STATUS_M_RSVD_25 = 0
HFC_STATUS_M_LYR_ENERGY = 0
HFC_STATUS_M_LYR_COUNTS = 0
HFC_STATUS_M_GEM_NOTKR = 0
HFC_STATUS_M_GEM_NOCALLO = 75
HFC_STATUS_M_GEM_NOCNO = 66354
HFC_STATUS_M_VETOED = 66429
OnboardFilter.D... INFO – DFC Filter bit frequency table –
Status Bit Value
DFC_STATUS_M_STAGE_GEM 66429
Veto Bit Summary
Trigger Name Count
DFC_STATUS_M_GEM_CLASSES 66429
DFC_STATUS_M_VETOED 66429
OnboardFilter INFO Encountered 0 events with no ebf data
GlastRelease 17-35-24-lp28
EventSelector INFO Processed 66429 event from a file containing 66429 events
EventLoopMgr INFO No more events in event selection
TriggerAlg INFO Totals triggered/ processed: 66429/66429
bit frequency: all events
value count CNO CALHI CALLO TKR ROI
---- --- --- --- --- ---
0 723 0 0 0 0 0
2 46357 0 0 0 46357 0
3 2279 0 0 0 2279 2279
4 9 0 0 9 0 0
6 7565 0 0 7565 7565 0
7 1997 0 0 1997 1997 1997
12 65 0 65 65 0 0
14 1106 0 1106 1106 1106 0
15 4337 0 4337 4337 4337 4337
18 1 1 0 0 1 0
19 71 71 0 0 71 71
22 1 1 0 1 1 0
23 284 284 0 284 284 284
28 1 1 1 1 0 0
31 1633 1633 1633 1633 1633 1633
---- --- --- --- --- ---
tot: 66429 1991 7142 16998 65631 10601
EbfWriter INFO Wrote 66429 Total Events
OnboardFilter.G... INFO – Gamma Filter Status Word bit frequency table –
GFC_V3_STATUS_M_GEM_THROTTLE = 10077
GFC_V3_STATUS_M_GEM_TKR = 66020
GFC_V3_STATUS_M_GEM_CALLO = 16734
GFC_V3_STATUS_M_GEM_CALHI = 7364
GFC_V3_STATUS_M_GEM_CNO = 1991
GFC_V3_STATUS_M_ACD_TOP = 10069
GFC_V3_STATUS_M_ACD_SIDE = 22182
GFC_V3_STATUS_M_ACD_SIDE_FILTER = 9894
GFC_V3_STATUS_M_TKR_EQ_1 = 15654
GFC_V3_STATUS_M_TKR_GE_2 = 21361
GFC_V3_STATUS_M_RSVD_10 = 0
GFC_V3_STATUS_M_TKR_LT_2_ELO = 4253
GFC_V3_STATUS_M_TKR_SKIRT = 8
GFC_V3_STATUS_M_TKR_EQ_0 = 24
GFC_V3_STATUS_M_TKR_ROW2 = 28
GFC_V3_STATUS_M_TKR_ROW01 = 49
GFC_V3_STATUS_M_TKR_TOP = 207
GFC_V3_STATUS_M_SIDE = 101
GFC_V3_STATUS_M_TOP = 170
GFC_V3_STATUS_M_ZBOTTOM = 45
GFC_V3_STATUS_M_ERR_CTB = 331
GFC_V3_STATUS_M_SPLASH_1 = 2113
GFC_V3_STATUS_M_E350_FILTER_TILE = 32
GFC_V3_STATUS_M_E0_TILE = 73
GFC_V3_STATUS_M_EL0_ETOT_HI = 3755
GFC_V3_STATUS_M_EL0_ETOT_LO = 9706
GFC_V3_STATUS_M_LO_ENERGY = 20328
GFC_V3_STATUS_M_HI_ENERGY = 3688
GFC_V3_STATUS_M_SPLASH_0 = 516
GFC_V3_STATUS_M_NOCALLO_FILTER_TILE = 2245
GFC_V3_STATUS_M_NON_PHYSICS = 171
GFC_V3_STATUS_M_VETOED = 4000
OnboardFilter.M... INFO – MIP Filter Status Word bit frequency table –
MFC_STATUS_M_STAGE_GEM = 66429
MFC_STATUS_M_STAGE_ACD = 0
MFC_STATUS_M_STAGE_DIR = 14156
MFC_STATUS_M_STAGE_CAL = 14156
MFC_STATUS_M_STAGE_XCAL = 14156
MFC_STATUS_M_MULTI_PKT = 1011
MFC_STATUS_M_ERR_CAL = 0
MFC_STATUS_M_ERR_CTB = 0
MFC_STATUS_M_ERR_DIR = 0
MFC_STATUS_M_RSVD_09 = 0
MFC_STATUS_M_RSVD_10 = 0
MFC_STATUS_M_RSVD_11 = 0
MFC_STATUS_M_RSVD_12 = 0
MFC_STATUS_M_RSVD_13 = 0
MFC_STATUS_M_RSVD_14 = 0
MFC_STATUS_M_RSVD_15 = 0
MFC_STATUS_M_RSVD_16 = 0
MFC_STATUS_M_RSVD_17 = 0
MFC_STATUS_M_RSVD_18 = 0
MFC_STATUS_M_RSVD_19 = 0
MFC_STATUS_M_RSVD_20 = 0
MFC_STATUS_M_RSVD_21 = 0
MFC_STATUS_M_RSVD_22 = 0
MFC_STATUS_M_RSVD_23 = 0
MFC_STATUS_M_RSVD_24 = 0
MFC_STATUS_M_RSVD_25 = 0
MFC_STATUS_M_NO_TKR_ADJ = 7361
MFC_STATUS_M_LYR_COUNTS = 11972
MFC_STATUS_M_NO_ACD_TKR = 49867
MFC_STATUS_M_GEM_NOTKR = 409
MFC_STATUS_M_GEM_CNO = 1997
MFC_STATUS_M_VETOED = 64245
OnboardFilter.H... INFO – HIP Filter Status Word bit frequency table –
HFC_STATUS_M_STAGE_GEM = 66429
HFC_STATUS_M_STAGE_DIR = 1918
HFC_STATUS_M_STAGE_CAL = 1918
HFC_STATUS_M_STAGE_CAL_ECHK = 1918
HFC_STATUS_M_STAGE_CAL_LCHK = 687
HFC_STATUS_M_MULTI_PKT = 1397
HFC_STATUS_M_ERR_CAL = 0
HFC_STATUS_M_ERR_CTB = 0
HFC_STATUS_M_ERR_DIR = 0
HFC_STATUS_M_RSVD_09 = 0
HFC_STATUS_M_RSVD_10 = 0
HFC_STATUS_M_RSVD_11 = 0
HFC_STATUS_M_RSVD_12 = 0
HFC_STATUS_M_RSVD_13 = 0
HFC_STATUS_M_RSVD_14 = 0
HFC_STATUS_M_RSVD_15 = 0
HFC_STATUS_M_RSVD_16 = 0
HFC_STATUS_M_RSVD_17 = 0
HFC_STATUS_M_RSVD_18 = 0
HFC_STATUS_M_RSVD_19 = 0
HFC_STATUS_M_RSVD_20 = 0
HFC_STATUS_M_RSVD_21 = 0
HFC_STATUS_M_RSVD_22 = 0
HFC_STATUS_M_RSVD_23 = 0
HFC_STATUS_M_RSVD_24 = 0
HFC_STATUS_M_RSVD_25 = 0
HFC_STATUS_M_LYR_ENERGY = 1191
HFC_STATUS_M_LYR_COUNTS = 281
HFC_STATUS_M_GEM_NOTKR = 0
HFC_STATUS_M_GEM_NOCALLO = 72
HFC_STATUS_M_GEM_NOCNO = 64439
HFC_STATUS_M_VETOED = 65983
OnboardFilter.D... INFO – DFC Filter bit frequency table –
Status Bit Value
DFC_STATUS_M_STAGE_GEM 66429
Veto Bit Summary
Trigger Name Count
DFC_STATUS_M_GEM_CLASSES 66429
DFC_STATUS_M_VETOED 66429
OnboardFilter INFO Encountered 0 events with no ebf data
ParticlePropert... INFO Service finalised successfully
The plots below show the rations of OBF to FSW variables with GAMMA/HIP/MIP filters for run 351769427, with B1-1-3 and B3-0-0-gl1. The ratios should always be 1, except in the case of MIP, because that filter was never used on the LAT. B3-0-0-gl1 fixes the problem with the HIP filter.
|
B1-1-3 |
B3-0-0 |
GAMMA |
|
|
MIP |
|
|
HIP |
|
|
Next up we ran a B1-1-3-era evt file through digitization to see what would happen:
/nfs/farm/g/glast/u28/RePipe/245777306/r0245777306/r0245777306-e00000000000000101081.evt
Both lp22 and lp28 failed to process this fail in the same way. Maybe that's not surprising, unless we modify the settings ?
GlastRelease 17-35-24-lp22
ConfigSvc INFO Read sampler data from file /afs/slac/g/glast/moot/archive-mood/Constit/2008-09/XFC_DB/000001da-dgn_gem.xml
TriggerAlg ERROR FMX key from moot (7089) doesn't match key from data (16784305 for DGN handler in mode 0!!!
EventLoopMgr WARNING Execution of algorithm Top failed
EventLoopMgr ERROR Error processing event loop.
EventLoopMgr ERROR Terminating event processing loop due to errors
EventLoopMgr ERROR Terminating event processing loop due to errors
TriggerAlg INFO Totals triggered/ processed: 1/1
bit frequency: all events
value count CNO CALHI CALLO TKR ROI
---- --- --- --- --- ---
0 1 0 0 0 0 0
---- --- --- --- --- ---
tot: 1 0 0 0 0 0
EbfWriter INFO Wrote 0 Total Events
OnboardFilter INFO Encountered 0 events with no ebf data
GlastRelease 17-35-24-lp28
ConfigSvc INFO Read sampler data from file /afs/slac/g/glast/moot/archive-mood/Constit/2008-09/XFC_DB/000001da-dgn_gem.xml
TriggerAlg ERROR FMX key from moot (7089) doesn't match key from data (16784305 for DGN handler in mode 0!!!
EventLoopMgr WARNING Execution of algorithm Top failed
EventLoopMgr ERROR Error processing event loop.
EventLoopMgr ERROR Terminating event processing loop due to errors
EventLoopMgr ERROR Terminating event processing loop due to errors
TriggerAlg INFO Totals triggered/ processed: 1/1
bit frequency: all events
value count CNO CALHI CALLO TKR ROI
---- --- --- --- --- ---
0 1 0 0 0 0 0
---- --- --- --- --- ---
tot: 1 0 0 0 0 0
EbfWriter INFO Wrote 0 Total Events
OnboardFilter INFO Encountered 0 events with no ebf data