Demonstrating we can run on the bulletq

Using GR 20-08-11 and running the default Gleam unit test to produce the resulting merit file using the RHEL5-64 boxes and then again on the bulletq (RHEL6-64).  Attached is the log from both the RHEL5-64 and RHEL6-64 runs as well as the jobOptions.txt.  We then ran Luca Baldini's meritDiff.py on the resulting merit files.  There were some differences - most are Aud*** variables - so are associated with the running times, which are unsurprisingly different.  Other differences are noted here:

Event @ row 21:
AudGeneration: 0.127981 vs. 0.110983
AudLinkTool_multiLink: 0.061991 vs. 0.050992
AudTreeBasedTool_link: 0.061991 vs. 0.050992
TFPBestAverageDist: 5.94514 vs. 5.76677
TFPBestPosY: 274.398 vs. 271.556
TFPBestRmsTrans: 1.24272 vs. 1.04039

Event @ row 24:
AudCal2: 0.303954 vs. 0.192971
AudEvent: 0.444932 vs. 0.321951
AudReconstruction: 0.321951 vs. 0.208969
TFPBestAverageDist: 5.38838 vs. 5.34987

Event @ row 34:
AudEvent: 0.447932 vs. 0.436934
AudLinkTool_multiLink: 0.115982 vs. 0.102985
AudTreeBasedTool_link: 0.115982 vs. 0.102985
CTBCORE: 0.632446587086 vs. 0.610946714878
TFPBestAverageDist: 14.9875 vs. 13.5671
TFPBestRmsTrans: 2.0324 vs. 1.12304
WP8CTCORE: 0.632446587086 vs. 0.610946714878

Event @ row 39:
AudCal2: 0.298954 vs. 0.184972
AudEvent: 0.538918 vs. 0.403939
AudGeneration: 0.116982 vs. 0.103984
AudReconstruction: 0.39694 vs. 0.276958
TFPBestAverageDist: 5.59284 vs. 5.49224

Event @ row 41:
AudEvent: 0.193971 vs. 0.179972
TFPBestAverageDist: 2.54451 vs. 2.51207

Event @ row 42:
AudGeneration: 0.13098 vs. 0.119982
AudLinkTool_multiLink: 0.109983 vs. 0.094986
AudTreeBasedTool_link: 0.109983 vs. 0.094986
TFPBestRmsTrans: 0.866189 vs. 0.754294

Event @ row 43:
TFPBestPosY: -597.941 vs. -597.967

Event @ row 71:
AudCal2: 0.334949 vs. 0.205969
AudEvent: 1.17382 vs. 1.00985
AudGeneration: 0.12798 vs. 0.116982
AudReconstruction: 1.02384 vs. 0.870867
AudTkr: 0.673897 vs. 0.651901
TFPBestRmsTrans: 1.1348 vs. 0.94005

Event @ row 82:
AudCal2: 0.302954 vs. 0.186972
AudEvent: 0.624905 vs. 0.488926
AudReconstruction: 0.481927 vs. 0.358945
TFPBestAverageDist: 5.29162 vs. 5.23858
TFPBestDirX: 0.0282077 vs. 0.00116588
TFPBestPosX: -256.776 vs. -260.601
TFPBestRmsLong: 13.6595 vs. 12.2954

Event @ row 89:
AudEvent: 0.185972 vs. 0.168974
TFPBestAverageDist: 7.37761 vs. 6.80445
TFPBestDirX: -0.0227199 vs. -0.042725

Event @ row 101:
AudEvent: 0.184972 vs. 0.170974
TFPBestDirX: -0.171283 vs. -0.186804
TFPBestRmsLong: 10.6726 vs. 10.1841
TFPBestRmsTrans: 0.730886 vs. 0.592457

Event @ row 105:
AudEvent: 0.579912 vs. 0.556915
AudReconstruction: 0.462929 vs. 0.447932
AudTkr: 0.444933 vs. 0.431935
McFilterDirErr: 0.0181719 vs. 0.00387349
TFPBestAverageDist: 8.89193 vs. 7.28681
TFPBestDirX: 0.0899079 vs. 0.0711655
TFPBestRmsLong: 30.8908 vs. 30.84
TFPBestRmsTrans: 0.969271 vs. 0.644359

Event @ row 109:
AudEvent: 0.250962 vs. 0.234965
TFPBestAverageDist: 14.3477 vs. 14.1862

Event @ row 110:
AudEvent: 0.461929 vs. 0.434933
AudReconstruction: 0.331949 vs. 0.314952
AudTkr: 0.306953 vs. 0.293956
McFilterDirErr: 0.0165403 vs. 0.00623349
TFPBestDirY: 0.0669841 vs. 0.0563686
TFPBestPosY: 667.086 vs. 666.375
TFPBestRmsLong: 63.6851 vs. 62.3032

Event @ row 123:
AudEvent: 0.794879 vs. 0.755885
AudReconstruction: 0.668899 vs. 0.639902
AudTkr: 0.651901 vs. 0.625904
TFPBestAverageDist: 11.6819 vs. 11.37
TFPBestPosX: 646.737 vs. 646.603

Event @ row 127:
AudCal2: 0.377943 vs. 0.238964
AudEvent: 0.544917 vs. 0.39294
AudReconstruction: 0.409937 vs. 0.270959
McFilterDirErr: 0.0538278 vs. 0.0374734
TFPBestAverageDist: 1.7815 vs. 1.58486
TFPBestDirX: 0.0751011 vs. 0.0587672
TFPBestRmsTrans: 0.172935 vs. 0.119131

Event @ row 161:
TFPBestAverageDist: 4.68049 vs. 4.66525
TFPBestDirY: 0.00918868 vs. -0.0155627

Event @ row 168:
AudCal2: 0.303954 vs. 0.189971
AudEvent: 0.46293 vs. 0.335949
AudReconstruction: 0.322951 vs. 0.206969
TFPBestDirX: -0.0122107 vs. -0.0482098
TFPBestDirY: 0.101918 vs. 0.0915396

Event @ row 176:
AudEvent: 0.149977 vs. 0.135979
TFPBestRmsLong: 8.8727 vs. 7.92988

Event @ row 182:
AudCal2: 0.303953 vs. 0.188971
AudEvent: 0.482927 vs. 0.355946
AudReconstruction: 0.360945 vs. 0.243963
TFPBestDirX: -0.0919146 vs. -0.120096

Event @ row 185:
AudCal2: 0.308953 vs. 0.191971
AudEvent: 0.59391 vs. 0.465929
AudReconstruction: 0.443933 vs. 0.324951
TFPBestAverageDist: 3.54669 vs. 3.51208

Event @ row 188:
AudEvent: 0.173974 vs. 0.160976
TFPBestAverageDist: 6.34872 vs. 6.29589
TFPBestPosY: 269.903 vs. 269.849
TFPBestRmsLong: 32.0445 vs. 31.5559
TFPBestRmsTrans: 0.632436 vs. 0.253374

Event @ row 197:
McFilterDirErr: 0.0368144 vs. 0.00153973

Event @ row 221:
AudEvent: 0.147977 vs. 0.13498
TFPBestPosX: 729.444 vs. 729.429
TFPBestRmsLong: 22.6822 vs. 22.0289

Event @ row 234:
AudEvent: 0.144978 vs. 0.129981
TFPBestDirY: -0.140319 vs. -0.167726
TFPBestPosY: -39.9956 vs. -40.0108

Event @ row 236:
AudEvent: 0.210968 vs. 0.189971
AudGeneration: 0.123981 vs. 0.110983
TFPBestRmsLong: 60.8096 vs. 60.0202
TFPBestRmsTrans: 0.86399 vs. 0.648225

Event @ row 246:
AudEvent: 0.144978 vs. 0.12998
TFPBestRmsTrans: 0.421256 vs. 0.363803

Event @ row 252:
AudCal2: 0.355946 vs. 0.228965
AudEvent: 0.501923 vs. 0.358945
AudGeneration: 0.109983 vs. 0.098985
AudReconstruction: 0.368944 vs. 0.239963
TFPBestPosY: -266.787 vs. -266.929
TFPBestRmsTrans: 0.488309 vs. 0.453939

Event @ row 254:
AudEvent: 0.138979 vs. 0.126981
TFPBestRmsLong: 8.15583 vs. 7.80454
TFPBestRmsTrans: 0.140238 vs. 0.127573

Event @ row 265:
AudEvent: 0.386941 vs. 0.361945
TFPBestAverageDist: 3.08269 vs. 3.05315
TFPBestPosX: 737.329 vs. 737.243
TFPBestRmsLong: 18.7629 vs. 12.8538
TFPBestRmsTrans: 0.421953 vs. 0.335846

Event @ row 271:
AudEvent: 0.873867 vs. 0.836873
AudReconstruction: 0.756885 vs. 0.731888
AudTkr: 0.738888 vs. 0.714892
TFPBestPosX: -738.305 vs. -738.42

Event @ row 273:
AudEvent: 0.320951 vs. 0.294955
AudGeneration: 0.103984 vs. 0.092986
AudReconstruction: 0.193971 vs. 0.181973
TFPBestAverageDist: 12.074 vs. 11.8818

Event @ row 290:
AudCal2: 0.386941 vs. 0.243963
AudEvent: 0.697894 vs. 0.522921
AudGeneration: 0.130981 vs. 0.108984
AudReconstruction: 0.541917 vs. 0.39194
CTBCORE: 0.495342850685 vs. 0.48461908102
TFPBestAverageDist: 13.6334 vs. 13.4954
TFPBestPosX: -170.83 vs. -171.519
TFPBestRmsTrans: 0.838469 vs. 0.747267
WP8CTCORE: 0.495342850685 vs. 0.48461908102

Event @ row 293:
AudEvent: 0.173973 vs. 0.158975
AudGeneration: 0.108983 vs. 0.097985
TFPBestPosX: 506.732 vs. 506.702
TFPBestPosY: 516.674 vs. 516.648

Event @ row 297:
AudEvent: 0.221966 vs. 0.201969
AudGeneration: 0.122981 vs. 0.111983
TFPBestRmsLong: 23.3447 vs. 23.291

Event @ row 301:
AudEvent: 1.20982 vs. 1.17582
AudLinkTool_multiLink: 0.158976 vs. 0.135979
AudReconstruction: 1.04984 vs. 1.02584
AudTkr: 1.02584 vs. 1.00385
AudTreeBasedTool_link: 0.158976 vs. 0.135979
TFPBestRmsLong: 98.7866 vs. 43.0741
TFPBestRmsTrans: 1.12882 vs. 1.03324

Event @ row 307:
TFPBestPosY: -113.777 vs. -114.487
TFPBestRmsLong: 7.95732 vs. 7.03375

Event @ row 332:
AudEvent: 0.162975 vs. 0.144978
AudGeneration: 0.109983 vs. 0.095985
TFPBestAverageDist: 4.09653 vs. 4.07203
TFPBestPosY: -22.3079 vs. -22.3232

Event @ row 361:
AudEvent: 0.177973 vs. 0.162975
TFPBestRmsLong: 17.171 vs. 17.1206
TFPBestRmsTrans: 0.517482 vs. 0.359919

Event @ row 365:
AudEvent: 0.138978 vs. 0.125981
TFPBestPosY: -350.126 vs. -350.149

Event @ row 378:
AudEvent: 0.223966 vs. 0.204969
AudGeneration: 0.109984 vs. 0.098985
TFPBestAverageDist: 6.42174 vs. 5.47599
TFPBestPosX: 548.357 vs. 548.334
TFPBestRmsLong: 39.6196 vs. 39.5967

Event @ row 380:
AudEvent: 0.212967 vs. 0.19697
TFPBestAverageDist: 8.94397 vs. 5.49174
TFPBestDirX: -0.0640702 vs. -0.077927
TFPBestDirY: 0.0579042 vs. 0.046944
TFPBestRmsTrans: 0.984214 vs. 0.713179

Event @ row 382:
AudEvent: 0.703893 vs. 0.683896
TFPBestAverageDist: 7.00969 vs. 6.94444
TFPBestPosY: -227.755 vs. -228.0
TFPBestRmsTrans: 0.771518 vs. 0.588481

Event @ row 396:
AudEvent: 0.158976 vs. 0.142978
AudGeneration: 0.109984 vs. 0.098984
TFPBestRmsTrans: 0.40121 vs. 0.190982

Event @ row 403:
AudEvent: 0.174974 vs. 0.162976
TFPBestAverageDist: 6.74357 vs. 6.6154
TFPBestRmsTrans: 0.49655 vs. 0.419754

Event @ row 432:
TFPBestAverageDist: 0.29229 vs. 0.253942

Event @ row 435:
AudCal2: 0.306953 vs. 0.190971
AudEvent: 0.446932 vs. 0.316952
AudGeneration: 0.104984 vs. 0.093986
AudReconstruction: 0.320951 vs. 0.201969
TFPBestRmsLong: 20.1285 vs. 19.8857

Event @ row 445:
AudCal2: 0.39394 vs. 0.255961
AudEvent: 1.02884 vs. 0.870868
AudReconstruction: 0.882866 vs. 0.734889
TFPBestPosY: -271.814 vs. -271.829

Event @ row 453:
AudCal2: 0.302954 vs. 0.189971
AudEvent: 0.564914 vs. 0.435934
AudReconstruction: 0.437933 vs. 0.320951
TFPBestRmsLong: 31.7152 vs. 31.3317

Event @ row 455:
AudEvent: 0.539918 vs. 0.518921
AudReconstruction: 0.399939 vs. 0.388941
CTBCORE: 0.63412374258 vs. 0.607893645763
TFPBestAverageDist: 7.33199 vs. 4.85229
TFPBestRmsLong: 91.0677 vs. 90.9501
TFPBestRmsTrans: 1.77185 vs. 1.05651
WP8CTCORE: 0.63412374258 vs. 0.607893645763

Event @ row 456:
AudEvent: 0.174974 vs. 0.159976
TFPBestAverageDist: 5.5631 vs. 4.27486
TFPBestDirX: -0.111363 vs. -0.147661
TFPBestPosX: -362.394 vs. -363.578
TFPBestPosY: 86.5351 vs. 85.3829
TFPBestRmsTrans: 0.552184 vs. 0.35549

Event @ row 467:
CTBCORE: 0.450452148914 vs. 0.399081736803
McFilterDirErr: 0.09203 vs. 0.0273331
TFPBestAverageDist: 9.29447 vs. 7.65928
TFPBestChiSquare: 0.01236 vs. 0.00146249
TFPBestDirX: 0.0534345 vs. -0.00178823
TFPBestRmsLong: 29.2225 vs. 28.9907
TFPBestRmsTrans: 1.56832 vs. 0.539477
WP8CTCORE: 0.450452148914 vs. 0.399081736803

Event @ row 482:
AudEvent: 0.388941 vs. 0.367944
AudGeneration: 0.121981 vs. 0.110983
TFPBestAverageDist: 6.60327 vs. 6.26083
TFPBestDirX: -0.0205159 vs. -0.0325023
TFPBestPosX: -596.244 vs. -599.086
TFPBestRmsLong: 49.809 vs. 31.4959
TFPBestRmsTrans: 0.751781 vs. 0.489697

Event @ row 485:
TFPBestRmsLong: 26.1943 vs. 25.2097
TFPBestRmsTrans: 0.911812 vs. 0.885922

Event @ row 497:
AudEvent: 0.520921 vs. 0.497925
AudReconstruction: 0.404939 vs. 0.39194
AudTkr: 0.386941 vs. 0.374943
TFPBestAverageDist: 7.39574 vs. 7.35281

Event @ row 514:
AudCal2: 0.335949 vs. 0.206969
AudEvent: 0.639903 vs. 0.487926
AudReconstruction: 0.497924 vs. 0.357946
TFPBestAverageDist: 5.18277 vs. 5.11127
TFPBestRmsLong: 27.4384 vs. 27.4271

Event @ row 523:
AudEvent: 0.137979 vs. 0.124981
TFPBestRmsLong: 25.9481 vs. 18.3055

Event @ row 538:
AudEvent: 0.278958 vs. 0.26196
McFilterDirErr: 0.188802 vs. 0.176954
TFPBestAverageDist: 7.02493 vs. 6.74783
TFPBestRmsLong: 9.50125 vs. 9.47783

Event @ row 572:
TFPBestAverageDist: 4.8098 vs. 4.68651

Event @ row 588:
AudEvent: 0.116982 vs. 0.103984
TFPBestAverageDist: 2.66985 vs. 2.60294

Event @ row 593:
AudEvent: 1.00085 vs. 0.955855
AudGeneration: 0.122981 vs. 0.111983
AudReconstruction: 0.85487 vs. 0.823875
AudTkr: 0.839873 vs. 0.808877
TFPBestPosY: -558.882 vs. -558.897
TFPBestRmsLong: 34.0318 vs. 27.6988

Event @ row 595:
AudCal2: 0.316952 vs. 0.19497
AudEvent: 0.468929 vs. 0.333949
AudGeneration: 0.110983 vs. 0.099985
AudReconstruction: 0.33395 vs. 0.210968
CTBCORE: 0.410024493933 vs. 0.396120011806
TFPBestPosX: 484.902 vs. 484.295
TFPBestRmsLong: 13.158 vs. 10.9638
TFPBestRmsTrans: 0.313306 vs. 0.245405
WP8CTCORE: 0.410024493933 vs. 0.396120011806

Event @ row 615:
McFilterDirErr: 0.0232839 vs. 0.0123621
TFPBestRmsLong: 37.1313 vs. 37.1167
TFPBestRmsTrans: 1.25105 vs. 0.966535

Event @ row 622:
AudCal2: 0.353946 vs. 0.228965
AudEvent: 0.509923 vs. 0.371943
AudGeneration: 0.115983 vs. 0.105983
AudReconstruction: 0.371944 vs. 0.244963
TFPBestAverageDist: 1.59717 vs. 1.53861
TFPBestRmsTrans: 0.301676 vs. 0.271946

Event @ row 636:
AudCal2: 0.308953 vs. 0.190971
AudEvent: 0.530919 vs. 0.39694
AudGeneration: 0.110983 vs. 0.099985
AudReconstruction: 0.39394 vs. 0.272959
McFilterDirErr: 0.0326693 vs. 0.0103478
TFPBestAverageDist: 8.40883 vs. 7.16399
TFPBestDirX: 0.0912446 vs. 0.0619716
TFPBestRmsLong: 8.57037 vs. 8.55057
TFPBestRmsTrans: 0.342027 vs. 0.253143

Event @ row 643:
AudEvent: 0.454931 vs. 0.419936
AudGeneration: 0.108984 vs. 0.095985
AudReconstruction: 0.322951 vs. 0.303953
AudTkr: 0.301954 vs. 0.284957
TFPBestRmsLong: 26.3923 vs. 25.0204

Event @ row 644:
AudEvent: 0.211968 vs. 0.188971
AudReconstruction: 0.13198 vs. 0.117982
AudTkr: 0.116982 vs. 0.104984
TFPBestAverageDist: 4.42314 vs. 4.35919

Event @ row 670:
AudGeneration: 0.13498 vs. 0.120981
AudLinkTool_multiLink: 0.086987 vs. 0.07199
AudTreeBasedTool_link: 0.086987 vs. 0.07199
McFilterDirErr: 0.0238764 vs. 0.0111667
TFPBestAverageDist: 9.30315 vs. 8.80615
TFPBestDirY: -0.0907194 vs. -0.105005
TFPBestPosX: 482.985 vs. 482.943
TFPBestRmsLong: 37.7147 vs. 37.3761
TFPBestRmsTrans: 0.995007 vs. 0.703747

Event @ row 678:
AudEvent: 0.220966 vs. 0.205968
AudGeneration: 0.113983 vs. 0.102984
CTBCORE: 0.687077820301 vs. 0.66153717041
TFPBestAverageDist: 5.23867 vs. 4.69561
TFPBestDirY: -0.0082331 vs. -0.0234723
TFPBestPosY: 109.626 vs. 104.416
TFPBestRmsTrans: 1.48654 vs. 0.616927
WP8CTCORE: 0.687077820301 vs. 0.66153717041

Event @ row 682:
AudEvent: 0.598909 vs. 0.569913
AudReconstruction: 0.46193 vs. 0.442933
AudTkr: 0.440933 vs. 0.424935
TFPBestAverageDist: 6.05787 vs. 5.69647
TFPBestPosX: -296.426 vs. -296.443

Event @ row 687:
AudCal2: 0.345948 vs. 0.224965
AudEvent: 0.497924 vs. 0.362944
AudGeneration: 0.114983 vs. 0.103984
AudReconstruction: 0.360945 vs. 0.237964
TFPBestRmsLong: 23.0174 vs. 22.3212
TFPBestRmsTrans: 0.404299 vs. 0.391781

Event @ row 691:
TFPBestRmsTrans: 0.572626 vs. 0.526311

Event @ row 724:
AudCal2: 0.339949 vs. 0.217967
AudEvent: 0.774883 vs. 0.629904
AudGeneration: 0.122982 vs. 0.111983
AudReconstruction: 0.628904 vs. 0.495925
TFPBestRmsLong: 32.6175 vs. 32.5244

Event @ row 734:
AudCal2: 0.307953 vs. 0.19297
AudEvent: 0.455931 vs. 0.324951
AudGeneration: 0.109983 vs. 0.096986
AudReconstruction: 0.323951 vs. 0.206969
TFPBestAverageDist: 2.47233 vs. 2.38319
TFPBestRmsLong: 12.6456 vs. 12.6296

Event @ row 736:
AudEvent: 0.146978 vs. 0.132979
AudGeneration: 0.110983 vs. 0.099984
TFPBestAverageDist: 1.56013 vs. 1.53581
TFPBestRmsTrans: 0.353377 vs. 0.321228

Event @ row 783:
AudEvent: 0.368944 vs. 0.354946
TFPBestPosY: 605.236 vs. 605.214
TFPBestRmsLong: 31.3915 vs. 31.2396

Event @ row 784:
TFPBestRmsTrans: 0.222218 vs. 0.176829

  • No labels