Blog from January, 2023

Reason for change:

We request to deploy  datamonitoring/AlarmsCfg-07-00-35.   In this  new tag  we updated the limits the following DQM quantities:

Lac_Thresholds_FacePos_TH1_TowerCalLayerCalColumn_13_5_10

Lac_Thresholds_FacePos_TH1_TowerCalLayerCalColumn_2_4_3


Test Procedure:

This version of AlarmsCfg has been tested processing locally the monitoring products from different  LPA runs ( 695303900, 695833867).


Rollback procedure:

The package can be rolled back to the previous version by flipping a soft link. Also note that the package is completely independent from any other package running in the pipeline and will not cause a version change of L1Proc.

CCB JIRA:

SSC-455 - Getting issue details... STATUS

Details:

Relaxing alarm limits on Lac thresholds for 2 channels:

    - Lac_Thresholds_FacePos_TH1_TowerCalLayerCalColumn_13_5_10:   upper warning limit changed from 2.75 to 2.85  
    - Lac_Thresholds_FacePos_TH1_TowerCalLayerCalColumn_2_4_3:  upper warning limit changed from 2.75 to 2.85  
    relevant thread: https://www-glast.stanford.edu/protected/mail/datamon/1811.html