Reason for change:

We request to deploy  datamonitoring/AlarmsCfg-07-00-33.   In this  new tag  we updated the limits  on  some DQM quantities:

Lac_Thresholds_FaceNeg_TH1_TowerCalLayerCalColumn_13_1_4,   Lac_Thresholds_FacePos_TH1_TowerCalLayerCalColumn_1_1_2,  AcdPedPedMeanDeviation_PMTB_TH1 (channel 82).


Test Procedure:

This version of AlarmsCfg has been tested processing locally the monitoring products from different  LPA runs ( 682758265, 684628507, 684964766).


Rollback procedure:

The package can be rolled back to the previous version by flipping a soft link. Also note that the package is completely independent from any other package running in the pipeline and will not cause a version change of L1Proc.

CCB JIRA:

SSC-454 - Getting issue details... STATUS

Details:

-Relaxing alarm limits on Lac thresholds for two CAL channels:
     Lac_Thresholds_FaceNeg_TH1_TowerCalLayerCalColumn_13_1_4:   upper warning limit changed from 3 to 3.2  
     Lac_Thresholds_FacePos_TH1_TowerCalLayerCalColumn_1_1_2:  upper warning limit changed from 2.8 to 2.9
     relevant thread: https://www-glast.stanford.edu/protected/mail/datamon/1289.html
-Relaxing alarm limits on AcdPedPedMeanDeviation_PMTB_TH1 for channel 82:
     Lower warning limit changed from -8.0  to -15.0
     Lower error limit changed from -15.0  to -20.0
     relevant thread: https://www-glast.stanford.edu/protected/mail/datamon/1133.html