Reason for change:

We request to deploy  datamonitoring/AlarmsCfg-07-00-32. 

 In this  new tag  we updated the limits  on  some DQM quantities:

Lac_Thresholds_FacePos_TH1_TowerCalLayerCalColumn_1_4_0,

ReconAcd2PhaMipsCorrectedAngle_PMTA_Zoom_TH1_AcdTile_62,

ReconAcd2PhaMipsCorrectedAngle_PMTB_Zoom_TH1_AcdTile_46

ReconAcd2PhaMipsCorrectedAngle_PMTB_Zoom_TH1_AcdTile_59

ReconAcd2PhaMipsCorrectedAngle_PMTB_Zoom_TH1_AcdTile_61 

Test Procedure:

This version of AlarmsCfg has been tested processing locally the monitoring products from different  LPA runs ( 678106138, 678613557, 676595731,655238687, 678766831)


Rollback procedure:

The package can be rolled back to the previous version by flipping a soft link. Also note that the package is completely independent from any other package running in the pipeline and will not cause a version change of L1Proc.

CCB JIRA:

SSC-452 - Getting issue details... STATUS

Details:

-Relaxing warning limits on ReconAcd2PhaMipsCorrectedAngle_PMT*_Zoom_TH1_AcdTile_* for 4 ACD channels:  
     tile 62 PMTA
     tile 46 PMTB
     tile 59 PMTB
     tile 61 PMTB
     lower warning limit changed from 0.9 to 0.8
     Relevant thread:  https://www-glast.stanford.edu/protected/mail/datamon/0813.html

-Relaxing alarm limits on Lac_Thresholds_FacePos_TH1_TowerCalLayerCalColumn_1_4_0:
    upper warning limit changed from 2.75 to 2.85
    Relevant thread: https://www-glast.stanford.edu/protected/mail/datamon/0962.html