Reason for change:
We request to deploy datamonitoring/AlarmsCfg-07-00-27. In this new version we updated the limits on AcdPedPedMeanDeviation_PMTA_TH1 for ACD tile 79.
A more detailed description can be found in the last section of this page.
Test Procedure:
This version of AlarmsCfg has been tested processing locally the monitoring products from 2 LPA runs ( 648667339, 648734916)
Rollback procedure:
The package can be rolled back to the previous version by flipping a soft link. Also note that the package is completely independent from any other package running in the pipeline and will not cause a version change of L1Proc.
CCB JIRA:
- SSC-447Getting issue details... STATUS
Details:
Relaxing warning limit for AcdPedPedMeanDeviation_PMTA_TH1 (ACD tile 79) in AlarmCfg/ xml/acdpeds_eor_alarms.xml:
-Upper warning limit changed from 8 to 10
Relevant thread: https://www-glast.stanford.edu/protected/mail/datamon/22798.html
Reason for change:
We request to deploy datamonitoring/AlarmsCfg-07-00-25. In this new tag we updated the limits for the LAC threshold for three cal channels: Lac_Thresholds_FaceNeg_TH1_TowerCalLayerCalColumn_13_1_1, Lac_Thresholds_FacePos_TH1_TowerCalLayerCalColumn_11_7_2, Lac_Thresholds_FaceNeg_TH1_TowerCalLayerCalColumn_4_5_10. A detailed description can be found in the last section of this page.
Test Procedure:
This version of AlarmsCfg has been tested processing locally the monitoring products from 2 LPA runs ( 647036677, 647116531)
Rollback procedure:
The package can be rolled back to the previous version by flipping a soft link. Also note that the package is completely independent from any other package running in the pipeline and will not cause a version change of L1Proc.
CCB JIRA:
-
SSC-446Getting issue details...
STATUS
Details:
-Relaxing alarm limits on Lac thresholds for 3 channels:
Lac_Thresholds_FaceNeg_TH1_TowerCalLayerCalColumn_13_1_1: upper warning limit changed from 2.95 to 3.1, upper error limit form 3 to 3.5
Lac_Thresholds_FacePos_TH1_TowerCalLayerCalColumn_11_7_2: upper warning limit changed from 2.95 to 3.1, upper error limit form 3 to 3.5
Lac_Thresholds_FaceNeg_TH1_TowerCalLayerCalColumn_4_5_10: upper warning limit changed from 2.75 to 2.85