Reason for change:
We request to put AlarmsCfg-07-00-17 in production. In this new tag we updated the alarm limits for some CAL quantities:
CalXAdcPedPedMean/RMSDifference_LEX8/1 for channel 2997 and CalXAdcPedRMS_LEX8 (for the average of all channels).
A detailed description can be found in the last section of this page.
Test Procedure:
This version of AlarmsCfg has been tested processing locally the monitoring products from three LPA runs ( 594965662, 595416944, 595439827).
Rollback procedure:
The package can be rolled back to the previous version by flipping a soft link. Also note that the package is completely independent from any other package running in the pipeline and will not cause a version change of L1Proc.
CCB JIRA:
- SSC-434Getting issue details... STATUS
Details:
- CalXAdcPedRMS_LEX8_TH1 (y_average): upper warning limit changed from 5.75 to 5.85Relevant thread: https://www-glast.stanford.edu/protected/mail/datamon/20149.html
- Relaxing limits on CalXAdcPedPedMean/RMSDifference_LEX8/1 for channel 2997:
CalXAdcPedPedMeanDifference_LEX8 new limits: [-20|-15|-|8|15]
CalXAdcPedPedRMSDifference_LEX8 new limits: [-20|-15|-|8|15]
CalXAdcPedPedMeanDifference_LEX1 new limits: [-2|-1|-|1.5|2]
CalXAdcPedPedRMSDifference_LEX1 new limits: [-3|-2|-|2|3]
Relevant thread: https://www-glast.stanford.edu/protected/mail/datamon/20308.html