Blog from April, 2016

Reason for change

We request to put  AlarmsCfg-07-00-05 in production. In the new tag we are relaxing the upper warning limit on the quantity "OutF_NormRateEvtsBeforeFilters", as detailed in the last section of this page.

Test Procedure

This version of AlarmsCfg has been tested processing locally the monitoring products from three  LPA runs (480738237,480690519 and  480652685).

Rollback procedure

The package can be rolled back to the previous version by flipping a soft link. Also note that the package is completely independent from any other package running in the pipeline and will not cause a version change of L1Proc.

CCB JIRA

SSC-410 - Request to update alarm settings in L1Proc 5.5

Details

From release notes for AlarmCfg-07-00-05:

    Relaxing warning limit on the quantity "OutF_NormRateEvtsBeforeFilters" in xml/merit_trend_alarms.xml:

    upper warning limit changed from 1.17 to 1.24.

 

In the last months the warnings on the quantity "OutF_NormRateEvtsBeforeFilters"  became quite common. The plot below shows the trend of the number of warnings over the last ~2 years (blue line). Most of them are at the beginning or at the end of the runs, when the spacecraft is entering or leaving the SAA. The red line shows the number of warnings with the new limit.

 

Relevant threads:

https://www-glast.stanford.edu/protected/mail/datamon/15624.html