Reason for change
This is just ordinary maintenance of the alarm limits. We require to put AlarmsCfg-06-01-02 in production.
The detailed description of the changes is in the last section.
Test Procedure
We have processed monitoring products from real on-orbit data (LPA) locally with this version of AlarmsCfg.
Rollback procedure
The package can be rolled back to the previous version by flipping a soft link. Also note that the package is completely independent from any other package running in the pipeline and will not cause a version change of L1Proc.
CCB Jira
Details (relese notes for AlarmsCfg-06-01-02)
- Calorimeter channels 1692 pushed in the group of the guys with higher limits (30/30) for the calpeds eor alarm on CalXAdcPedRMS_LEX8_TH1, algorithm y-values.
- Limits on the GPSInLock_TH1, x-average alarm loosened a little bit.
- Relevant thread: https://www-glast.stanford.edu/protected/mail/datamon/10008.html
Reasons for Change
- Update to use ScienceTools-09-32-05 for P7REP_*_V15 irfs.
- Update script to generate Monitored Source List FITS file sent to the FSSC
Test Procedure
Tested in dev on data in /ASP/TestSims2 and on prod tables for Monitored Source List FITS file generation.
Rollback Procedure
Revert to ASP-06-01-01 (ScienceTools-09-29-00)
CCB Jira
Details
- pyASP-04-00-03
- Modified FitsNTuple.py to accommodate interface changes in pyfits-3.1 (used by python 2.7.2 in extlibs)
- grbASP-05-03-02
- Modified BlindSearch.py, LatGrbSpectrum.py, extractLatData.py, makeRefinementPlots.py for pyfits-3.1 changes.
- drpMonitoring-02-00-03
- Use new make_monitored_source_list.py instead of old makeDrpLcTables.py
This page gathers a bit of information about CPU time used by the Pass8 GRs.
Here is the associate Jira item: LPATE-102@JIRA
Links
Summary
- Pretty stable in the past months, we've improved some things but also added more
- As of GR 20-08-10: Tkr, CAL2 and Other are each 1/3 of total CPU
- CRFinder is 15% of total CPU, must be speed up
- Have to look into the merit tuple Auditor variables
- Work to be done on outliers
- Outliers in the plots below are jobs running on slow machines (fell)
- Outliers seem to be related to swapping
- I'll try to ask for more 2GB of RAM instead of just 1GB when submitting jobs, it may help speeding up things
Plots
- I gather data from log files of the Pass8 Solar Flare reprocessing task:
/nfs/farm/g/glast/u44/CalibSets-Tasks/Pass8_SFRs_Repro/output/Pass8_SFRs_Repro/"version"/run-setupCrumbs/digi-skimNrepro-crumb/runPass8Repro/"run"/"chunk"/"crumb"/logFile.txt with "version" in ['2.6', '2.7', '2.8', '2.9'] corresponding to GR 20-08-06 to 20-08-10
- All CPU times are normalized to jobs running on the hequ workers
- CPU Time since 20-08-00
- Plot for the past 4 releases: 20-08-06 to 20-08-10 (GRScan_p6Top10.root)
| | |
CPU Time
RAM
Swap
Cal2 (Energy)
Tkr First Pass
Tkr Tree Links
Tkr Tree
Breaking up 20-08-11
- Global performances
- Outliers at 3 sigma
Min/Average/Max CPU time 548/2521/6401 CPU outliers host hequ run 1 chunk 15 crumb 45 normcpu 2751.960000 host kiso run 2 chunk 22 crumb 10 normcpu 2953.872000 host kiso run 2 chunk 22 crumb 46 normcpu 2685.288000 host kiso run 2 chunk 22 crumb 42 normcpu 2820.112000 host hequ run 2 chunk 22 crumb 38 normcpu 3027.380000 host kiso run 2 chunk 22 crumb 124 normcpu 2654.792000 host kiso run 2 chunk 22 crumb 123 normcpu 2795.560000 host fell run 2 chunk 21 crumb 52 normcpu 2883.887500 host kiso run 2 chunk 5 crumb 92 normcpu 2854.632000 host kiso run 2 chunk 5 crumb 76 normcpu 2829.296000 host kiso run 2 chunk 5 crumb 24 normcpu 2767.400000 host fell run 2 chunk 23 crumb 18 normcpu 4000.725000 SWAP outliers host boer run 1 chunk 15 crumb 39 swap 2545.000000 host boer run 1 chunk 15 crumb 25 swap 2584.000000 host boer run 1 chunk 24 crumb 13 swap 2553.000000 host fell run 2 chunk 22 crumb 132 swap 2551.000000 host dole run 2 chunk 5 crumb 63 swap 2591.000000 CAL2 outliers host kiso run 2 chunk 22 crumb 10 normcal2 931.200000 host kiso run 2 chunk 22 crumb 42 normcal2 936.000000 host fell run 2 chunk 21 crumb 52 normcal2 1245.000000 host kiso run 2 chunk 5 crumb 76 normcal2 960.000000 host fell run 2 chunk 23 crumb 18 normcal2 1102.500000 TREE outliers host hequ run 1 chunk 15 crumb 45 normtree 1320.000000 host hequ run 2 chunk 22 crumb 38 normtree 1590.000000 host boer run 2 chunk 5 crumb 42 normtree 920.000000 host fell run 2 chunk 23 crumb 18 normtree 2073.750000 LINK outliers host kiso run 2 chunk 22 crumb 10 normlink 389.600000 host kiso run 2 chunk 22 crumb 46 normlink 380.000000 host kiso run 2 chunk 22 crumb 42 normlink 385.600000 host kiso run 2 chunk 22 crumb 123 normlink 387.200000 host kiso run 2 chunk 5 crumb 92 normlink 360.000000 host kiso run 2 chunk 5 crumb 76 normlink 402.720000 FIRST outliers host hequ run 1 chunk 15 crumb 45 normfirst 1812.000000 host kiso run 2 chunk 22 crumb 10 normfirst 1627.200000 host kiso run 2 chunk 22 crumb 42 normfirst 1502.400000 host hequ run 2 chunk 22 crumb 38 normfirst 2070.000000 host kiso run 2 chunk 22 crumb 123 normfirst 1502.400000 host kiso run 2 chunk 5 crumb 92 normfirst 1526.400000 host fell run 2 chunk 23 crumb 18 normfirst 2576.250000
Breaking up 20-08-10
- Global performances
- Outliers at 3 sigma
CPU outliers host fell run 2 chunk 22 crumb 73 normcpu 3006.050000 host fell run 2 chunk 22 crumb 38 normcpu 3609.431250 host fell run 1 chunk 25 crumb 5 normcpu 4184.412500 SWAP outliers host fell run 2 chunk 5 crumb 5 swap 2590.000000 host boer run 2 chunk 5 crumb 108 swap 2586.000000 host hequ run 2 chunk 5 crumb 6 swap 2589.000000 host bali run 2 chunk 5 crumb 27 swap 2586.000000 host yili run 2 chunk 5 crumb 84 swap 2549.000000 host boer run 2 chunk 21 crumb 32 swap 2579.000000 host boer run 2 chunk 22 crumb 71 swap 2585.000000 host fell run 2 chunk 22 crumb 50 swap 2542.000000 host fell run 2 chunk 22 crumb 73 swap 2581.000000 host dole run 1 chunk 24 crumb 28 swap 2560.000000 host dole run 1 chunk 24 crumb 19 swap 2583.000000 host fell run 1 chunk 24 crumb 23 swap 2631.000000 host hequ run 1 chunk 15 crumb 5 swap 2585.000000 host fell run 1 chunk 25 crumb 46 swap 2625.000000 host dole run 1 chunk 25 crumb 0 swap 2580.000000 host dole run 1 chunk 17 crumb 18 swap 2557.000000 host fell run 1 chunk 17 crumb 57 swap 2591.000000 host dole run 1 chunk 17 crumb 91 swap 2584.000000 host dole run 0 chunk 3 crumb 4 swap 2541.000000 CAL2 outliers host fell run 2 chunk 22 crumb 73 normcal2 1301.250000 host fell run 1 chunk 25 crumb 5 normcal2 1691.250000 Tkr TREE outliers host dole run 2 chunk 23 crumb 18 normtree 939.622642 host fell run 2 chunk 22 crumb 14 normtree 795.000000 host fell run 2 chunk 22 crumb 38 normtree 2006.250000 host kiso run 1 chunk 15 crumb 45 normtree 1012.800000 host fell run 1 chunk 25 crumb 5 normtree 990.000000 host fell run 1 chunk 25 crumb 10 normtree 862.500000 Tkr Tree LINK outliers host fell run 2 chunk 5 crumb 99 normlink 386.250000 host fell run 2 chunk 22 crumb 73 normlink 390.000000 host fell run 1 chunk 25 crumb 5 normlink 540.000000 Tkr FIRST outliers host dole run 2 chunk 23 crumb 18 normfirst 1386.792453 host fell run 2 chunk 22 crumb 38 normfirst 2445.000000 host kiso run 1 chunk 15 crumb 45 normfirst 1483.200000 host fell run 1 chunk 25 crumb 5 normfirst 1882.500000