Reason for change
The new version (AlarmsCfg-05-23-05, as opposed to AlarmsCfg-05-23-01) features a few minor limit changes and protections against low statistics (see details below).
Test Procedure
We have processed monitoring products from real on-orbit data (LPA) locally with this version of AlarmsCfg.
Rollback procedure
The package can be rolled back to the previous version by flipping a soft link. Also note that the package is completely independent from any other package running in the pipeline and will not cause a version change of L1Proc.
CCB Jira
Details (release notes for dataMonitoring/AlarmCfg for AlarmsCfg-05-23-05)
- AlarmsCfg-05-23-05 15-Feb-2010 lbaldini A few alarms protected against low statistics.
- Some alarms protected against low statistics:
- CondArrCalLo_CalHiOpensWindow_TH1 (reference_histogram): min_entries = 5000 (both digi and fastmon eor).
- CondArrCalLowTrigger_TH1 (reference_histogram): min_entries = 10000 (both digi and fastmon eor).
- AcdSingleVetoMap_TH1 (x_average and x_rms): min_entries = 10000 (digi eor).
- CrateNumber_TH1 (x_average): min_entries = 10000 (digi eor).
- CondArrROITrigger_TH1 (x_average and x_rms): min_entries = 10000 (both digi and fastmon eor).
- CondArrTKRTrigger_TH1 (x_average and x_rms): min_entries = 10000 (both digi and fastmon eor).
- CondArrCalHi_CalLoOpensWindow_TH1 (x_average and x_rms): min_entries = 1000 (both digi and fastmon eor).
- CondArrTKR_CalHiOpensWindow_TH1 (x_average and x_rms): min_entries = 5000 (both digi and fastmon eor).
- CondArrROI_CalLoOpensWindow_TH1 (x_average and x_rms): min_entries = 1000 (both digi and fastmon eor).
- Some alarms protected against low statistics:
- AlarmsCfg-05-23-04 15-Feb-2010 lbaldini Minor limit change.
- A couple of minor limit changes for the alarms on the arrival times for both the digi and the FastMon eor.
- CondArrTKR_CalHiOpensWindow_TH1 (low_high_ratio, pivot = 31): warning max: 5000 -> 5500, error max : 8000 -> 10000
- CondArrTKRTrigger_TH1 (low_high_ratio, pivot = 31): warning max: 30000 -> 35000
- A couple of minor limit changes for the alarms on the arrival times for both the digi and the FastMon eor.
- AlarmsCfg-05-23-03 09-Feb-2010 lbaldini Minor limit change.
- Lower warning limit for the digi trend OutF_Normalized_AcdHit_AcdTile quantity (tiles 15, 31, 47, 63) changed from 0.12 to 0.11.
- AlarmsCfg-05-23-02 09-Feb-2010 lbaldini Minor limit change.
- Lower warning limit for the merit trend OutF_NormRateEvtsBeforeFilters quantity changed from 0.85 to 0.80 (it was a bit too tight).
Reason for change
The new version (AlarmsCfg-05-23-01, as opposed to AlarmsCfg-05-22-05) is mainly for putting in the new alarm limits on the merit normalized rates after the new normalization factors have been put into production. There are a few minor more minor changes, mainly in order to protect alarms against low statistics, which are detailed below.
Test Procedure
We have processed monitoring products from real on-orbit data (LPA) locally with this version of AlarmsCfg.
Rollback procedure
The package can be rolled back to the previous version by flipping a soft link. Also note that the package is completely independent from any other package running in the pipeline and will not cause a version change of L1Proc.
CCB Jira
Details (release notes for dataMonitoring/AlarmCfg for AlarmsCfg-05-23-01)
- AlarmsCfg-05-23-01 04-Feb-2010 lbaldini Minor change.
- Alarm on the digi eor GPSInLock_TH1 protected against low statistics (condition on min entrioes changed from 500 to 1250).
- AlarmsCfg-05-23-00 04-Feb-2010 lbaldini Alarms on the normalized rates retuned.
- Retuned the alarms on the normalized rates after the new normalization factors have been put in production.
- Relevant Jira(s): GDQMQ-317.
- AlarmsCfg-05-22-06 04-Feb-2010 lbaldini Minor changes.
- Condition on the minimum number of entries changed for CondArrCNO_CalLoOpensWindow_TH1 (reference_histogram algorithm, both digi and fastmon end-of-run) changed from 1000 to 2500.
- Upper warning limit for the alarm on the digi trending quantity Rate_NTkrHits_TowerPlane changed from 2.5 to 2.75. See the thread https://www-glast.stanford.edu/protected/mail/datamon/3560.html for more details.