Reason for change
The new version contains some fine tuning of specific limits; the proposed version of the dataMonitoring/AlarmsCfg package is v5r8p0, as opposed to v5r7p3, previously running in L1Proc 1.69.
The detailed description of the changes is in the last section.
Test Procedure
We have processed monitoring products from real on-orbit data (LPA) locally with this version of AlarmsCfg.
Rollback procedure
The package can be rolled back to the previous version by flipping a soft link. Also note that the package is completely independent from any other package running in the pipeline and will not cause a version change of L1Proc.
CCB Jira
Details
v5r8p0
- Added exception in tkr trend for tower 2, plane 31 (new noisy strip).
- Got rid of the alarm on Lac_Thresholds_FacePos_TH1_TowerCalLayerCalColumn_8_4_6 (waiting for the new calibration constants).
- CondArrTKR_CalHiOpensWindow_TH1 : low_high_ratio
- CondArrCalLo_CNOOpensWindow_TH1 : min entries = 100
- CondArrCalHi_CNOOpensWindow_TH1 : min entries = 100
- CondArrCNO_TKROpensWindow_TH1 : low_high_ratio
- CondArrCalHi_TKROpensWindow_TH1 : low_high_ratio
- Add requirements on the number of entries for most alarms using
the reference histograms.
Reason for change
The new version contains some fine tuning of specific limits; the proposed version of the dataMonitoring/AlarmsCfg package is v5r7p3, as opposed to v5r7p1, previously running in L1Proc 1.69.
The detailed description of the changes is in the last section.
Test Procedure
We have processed monitoring products from real on-orbit data (LPA) locally with this version of AlarmsCfg.
Rollback procedure
The package can be rolled back to the previous version by flipping a soft link. Also note that the package is completely independent from any other package running in the pipeline and will not cause a version change of L1Proc.
CCB Jira
Details
v5r7p3
- Two exceptions added for the new TKR noisy strip in tower 3, layer 1, GTFE 12.
- Fine tuning in CondArrROITrigger_TH1 : low_high ratio
- Fine tuning in CondArrTKR_CalHiOpensWindow_TH1 : low_high ratio
- Fine tuning in CondArrCalHi_CNOOpensWindow_TH1 : x_average
- Relevant jira(s): GDQMQ-291
v5r7p2
- New tuning of the alarms on the condition arrival times in fastmon and digi eor to avoid spurious alarms
- Relevant jira(s): GDQMQ-291
Reason for change
The proposed version of the dataMonitoring/AlarmsCfg package is v5r7p1, as opposed to v5r6p2, previously running in L1Proc 1.69.
The detailed description of the changes is in the last section.
Test Procedure
We have processed monitoring products from real on-orbit data (LPA) locally with this version of AlarmsCfg.
Rollback procedure
The package can be rolled back to the previous version by flipping a soft link. Also note that the package is completely independent from any other package running in the pipeline and will not cause a version change of L1Proc.
CCB Jira
Details
v5r7p1
- Improve alarms on condition arrival times, explicitly check the content of bin 31 against the sum over the other bins.
- Relevant jira(s): GDQMQ-299
v5r7p0
- Added two exceptions (in tkr trend and fastmon eor) for the new noisy strip in tower 0, plane 12, GTFE 14.
Reason for change
The proposed version of the dataMonitoring/AlarmsCfg package is v5r6p2, as opposed to v5r5p7, previously running in L1Proc 1.69.
The detailed description of the changes is in the last section.
Test Procedure
We have processed monitoring products from real on-orbit data (LPA) locally with this version of AlarmsCfg.
Rollback procedure
The package can be rolled back to the previous version by flipping a soft link. Also note that the package is completely independent from any other package running in the pipeline and will not cause a version change of L1Proc.
CCB Jira
Details
v5r6p2
- Changed limits on the CAL pedestals.
- Relevant jira(s): GDQMQ-279
v5r6p1
- Temporarily removed the alarms on the LAC thresholds of a couple of crystals.
- Relevant jira(s): GDQMQ-296
v5r6p0
- Exception added on digi trend Rate_NTkrHits_TowerPlane (tower 0, plane 14).
Reason for change
A bunch of new features:
- In the pgwave detection table trasforms the name of a source in a link to its light curve/table if it exists
- In the light curve table shows also the spectral index and error and the TS value.
- Add a new page to generale XML source model
Plus bug fixes.
Test Procedure
Create new view to simplify query to populate link in the pgwave detection table.
This is sql command to create view :
create view PointSourcesLightCurves as select distinct ptsrc_name from LightCurves.
This version has been tested on the DEV server.
Rollback procedure
Version 3.0 can be easily put back in place.
CCB Jira
Details
Reason for change
We have updates to the monitoring and monitoring alarms. No changes to any code that process data.
Test Procedure
We have processed data runs in the DEV pipeline with this version of L1Proc.
Rollback procedure
We can switch back to the previous version of L1Proc.
CCB Jira
Details
L1Pipeline v1r69:
- Run the alarms mechanism on the errors from Verify. Relevant jira(s): GDQMQ-250, LONE-117.
- Use reference histograms when doing alarms LONE-118@JIRA
- Increase scratch reservation when doing large merges s.t. only 1 should run on a host at once.
dataMonitoring/AlarmsCfg: v5r5p6
- Alarm reference_histogram on CondArrCalLowTrigger in fastmon eor re-enabled (after the reference file has been modified). Relevant jira(s): GDQMQ-290
- Alarm exception added on Tracker trend Number_layerOcc_TowerPlane, tower 3 plane 35. The subsystem experts are aware of the new noisy strip.
- One alarm (fastmon eor CondArrCalLowTrigger_TH1, reference histogram) disabled, since the name in the reference file is wrong.
- Couple of conditions on the number of entries added.
- Update and enable alarms on CondArrTime histograms for FastMon and Digi
- First tag that uses reference histograms
- Enable and tune alarm on CondSummaryWord. Relevant jira(s): GDQMQ-271
- Added alarms on y_average and y_rms in acdpedsanalyzer.
- Added alarms on y_average and y_rms in calpedsanalyzer.
- Added alarms on y_average and y_rms in calgainsanalyzer.
- Put condition on the minimum number of entries in all the acd/cal peds/gains analyzer alarms.
- Limits relaxed on AcdPedPedRMSDifference_PMTA_TH1 and AcdPedPedRMSDifference_PMTB_TH1 in acdped_eor.
- Limits relaxed on AcdPedPedMeanDifference_PMTA_TH1 and AcdPedPedMeanDifference_PMTB_TH1 in acdped_eor.
- Updated exceptions on the tracker occupancy plots in the electronics space.
- Added alarms on the errors from FastMon and Verify. Relevant jira(s): GDQMQ-250
dataMonitoring/FastMonCfg: v1r6p1
- Change name CondArrCalLoTrigger_TH1 to CondArrCalLowTrigger_TH1 to match Digi EOR name. Relevant jira(s): GDQMQ-274
dataMonitoring/DigiReconCalMeritCfg: v1r3p1
- Changes to address Jira GDQMQ-267.
- Add rate trending of each one of the error bits of the FastMon error_summary quantity.. Addresses JIRA GDQMQ-249
dataMonitoring/Common: v5r4p3
- Bug fix (malformed token in the output xml file) in alg__reference_histogram.
- Bug fix (unprotected float division) in alg__low_high_ratio.
- Added new algorithms alg__exponential_lambda and alg_powerlaw_index.
svac/TestReport: v7r5
- Fixed a bug that was generating spurious errors for sweep events
Complete set of tags for L1Proc 1.69
Code Versions
GlastRelease (sim/recon) v15r47p1
ScienceTools (Level 2) : v9r7p1
Science Ops (task defs, scripts):
Level 1 pipeline code and applications running in L1:
svac/L1Pipeline: v1r69*
calibTkrUtil v2r7p3
calibGenTKR v4r5
dataMonitoring/AlarmsCfg: v5r5p6*
dataMonitoring/FastMonCfg: v1r6p1*
dataMonitoring/DigiReconCalMeritCfg: v1r3p1*
dataMonitoring/Common: v5r4p3*
dataMonitoring/FastMon: v4r5p0
datMonitoring/IGRF: v1r0p1
svac/Monitor: v1r2p32*
svac/EngineeringModelRoot: v4r3
svac/TestReport: v7r5*
users/richard/pipelineDatasets: v0r6
ft2Util: v1r2p23
evtClassDefs v0r6
GPLtools: v1r13p1