How the build was configured on Windows 

Installed cygwin including gcc, make, etc  NOTE:  cygwin's link.exe application must be renamed, so that VC's link will be used for the build.
Obtained ROOT source from their CVS repository using the tag v5.14.00d
http://root.cern.ch/twiki/bin/view/ROOT/PatchesV5-14-00

Downloaded Python 2.5 for windows
We decided to upgrade to Python 2.5 at this point in the Core Meeting from March 13, 2007
We double-checked ROOT's abilty to handle this version of Python and were pleased to find this ROOT forum discussion:
http://root.cern.ch/phpBB2/viewtopic.php?t=4359

Obtained FFTW 3.1.2 from http://www.fftw.org/install/windows.html
downloaded:  libxml2-2.6.15.win32 from Planet Mirror
downloaded gccxml from http://www.gccxml.org/HTML/Index.html

Skipped CERNLIB, Oracle

From the DOS prompt, set path to "" and ran vsvars32.bat, defined

  • ROOTSYS to point to the root directory containing the source code
  • added Python to the path as well as %ROOTSYS%/lib and %ROOTSYS%/bin.
  • Updated the LIB env variable to include %ROOTSYS\lib
  • For release build set ROOTBUILD=opt, for debug set to debug
  • Set PYTHONDIR to the top level python directory
  • set PYTHONPATH to %ROOTSYS%\bin
  • set XMLDIR to point to the xml installation

Start cygwin via the command line:  bash --login -i
At the cygwin prompt, changed directories to the %ROOTSYS% dir and then ran configure:
./configure win32 --enable-roofit --enable-minuit2 --enable-table \
--enable-python --disable-odbc --enable-gdml \
--enable-unuran --enable-xrootd \
--with-fftw3-incdir=C:/heather/root-5.14d/fftw-3.1.2-dll \
--with-fftw3-libdir=C:/heather/root-5.14d/fftw-3.1.2-dll \
--with-gccxml=C:/heather/root-5.14d/gcc_xml \
--with-xml-incdir=C:/heather/root-5.14d/libxml2-2.6.15.win32/include \
--with-xml-libdir=C:/heather/root-5.14d/libxml2-2.6.15.win32/lib \
--with-python-libdir=C:/Python25/libs \
--with-python-incdir=C:/Python25/include

 
Note that ROOT-central lists the following as their configuration for the win32gdk build (as seen on the page: http://root.cern.ch/root/myconfig/Version514.config.html):

win32gdk

#import ruby from http://rubyinstaller.rubyforge.org/wiki/wiki.pl
export ROOTBUILD=opt
export ROOTSYS='c:\cygwin\home\brun\root'
export PYTHONDIR=/cygdrive/c/Python23
export PYTHONPATH='c:\cygwin\home\brun\root\bin'
export XMLDIR=$HOME/libxml2-2.6.9
#export PATH=`/usr/bin/cygpath -u $ROOTSYS`/bin:.:$PYTHONDIR:$MAINPATH:$ORACLE/vc71:$ORACLE
export PATH=$ORACLE/vc71:$ORACLE:$HOME/root/bin:.:$PYTHONDIR:$MAINPATH
./configure win32 \
--enable-roofit \
--enable-minuit2 \
--enable-table \
--enable-python \
--enable-odbc \
--enable-gdml \
--enable-unuran \
--enable-xrootd \
--with-fftw3-incdir=$HOME/fftw-3.1.1 \
--with-fftw3-libdir=$HOME/fftw-3.1.1 \
--with-gccxml=$HOME/gccxml/bin \
--with-xml-incdir=$HOME/libxml2-2.6.15.win32/libxml2-2.6.15.win32/include \
--with-xml-libdir=$HOME/libxml2-2.6.15.win32/libxml2-2.6.15.win32/lib \
--enable-oracle \
--with-oracle-incdir=$HOME/instantclient10_1/sdk/include \
--with-oracle-incdir=$HOME/instantclient10_1/sdk/include \
--with-oracle-libdir=$HOME/instantclient10_1/sdk/lib/msvc \
--with-python-incdir=$PYTHONDIR/include \
--with-python-libdir=$PYTHONDIR/libs \
--with-pythia6-libdir=$HOME/pythia6 \
--with-cern-libdir=$HOME/cernlib/2003/lib

renamed cygwin's link.exe to link_cyg.exe:
http://root.cern.ch/root/roottalk/roottalk06/1448.html
Avoids cygwin's link app from interfering with the build

make
make cintdlls  (which seems to do nothing)
make map
make install

  • No labels